[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-289665-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-289665-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","ewcm-eo-applications-index-rel-191212","EWCM EO Applications Index - rel. 19.12.12","","Index of EWCM EO .DAT applications provided by Eliwell for registered users. Lists specific EWCM EO model application mappings for devices including EWCM EO 9100 (13DIN) and EWCM EO 9900 (18DIN), with examples of single- and dual-circuit configurations, compressor types (ON/OFF and inverter), discharge and subcooling behaviors, synchronization modes, and gas cooler or redundant heat-exchanger options. Notes that applications do not change thresholds, alarm and safety times and may require adaptation to the target application. Also explains secured access and USB Copy Card download/reset steps.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/ewcm-eo-applications-index-rel-191212/289665/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/ewcm-eo-applications-index-rel-191212/289665.png","ImageObject",300,407,{"name":42,"@type":43},"Angel","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-06","2026-09-17",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",5,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the purpose of the EWCM EO Applications Index?","Question",{"text":63,"@type":64},"It lists EWCM EO .DAT applications provided by Eliwell for registered users and shows how each application maps to EWCM EO 9100 and 9900 models.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Do these applications change thresholds, alarm, or safety times?",{"text":68,"@type":64},"No. The index states that the applications do not modify threshold adjustments, alarm times, or safety times.",{"name":70,"@type":61,"acceptedAnswer":71},"How does downloading EWCM EO .DAT applications work with a USB Copy Card?",{"text":72,"@type":64},"Download the file on EWCM using the USB Copy Card, then remove the card; the system resets automatically.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},289665,1790196696,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":55,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":55},687207412472,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","EWCM   \nEWCM EO Applications Index rel. 19.12.12  \n.DAT Applications  \nThis index shows EWCM EO applications (. DAT) provided by Eliwell available on this zip file and on the website [www.eliwell.com ](www.eliwell.com for)[for](www.eliwell.com for) registered users  \nExamples refer to the models EWCM EO 9100 (13DIN) & EWCM EO 9900 (18DIN) with factory default settings The applications do not modify thresholds adjustment, alarm and safety times.  \nSome settings may require adaptation to the specific application.  \n\n| Applications | EWCM EO 9100 | EWCM EO 9900 |\n| --- | --- | --- |\n| EWCM EO + 1 x V910 through IO | 9100AB01 | 9900AB01 |\n| EWCM EO + 1 x V910 through LAN (RS485 EXP) | 9100AB02 | 9900AB02 |\n| EWCM EO LT/MT syncronization | 91BTAB03/91TNAB03 | 99BTAB03/99TNAB03 |\n| EWCM EO with Gas cooler | 9100AB04 | 9900AB04 |\n| EWCM EO with double heat exchanger (redundancy) | 9100AB05 | 9900AB05 |\n| EWCM EO 1 circuit , ON/OFF compressors,\u003Cbr>discharge with steps | 9100AB06 | 9900AB06 |\n| EWCM EO 1 circuit , ON/OFF compressors & INVERTER, discharge with steps | 9100AB07 | 9900AB07 |\n| EWCM EO 2 circuits , ON/OFF compressors & INVERTER, discharge with steps | - | 9900AB08 |\n| EWCM EO 1 circuit , ON/OFF compressors ,\u003Cbr>discharge with INVERTER | 9100AB09 | 9900AB09 |\n| EWCM EO 1 circuit , ON/OFF compressors & INVERTER , discharge with INVERTER | 9100AB10 | 9900AB10 |\n| EWCM EO 2 circuits , ON/OFF compressors & INVERTER , discharge with INVERTER | - | 9900AB11 |\n| EWCM EO 1 circuit , discharge with floating setpoint | 9100AB12 | 9900AB12 |\n| EWCM EO general regulator |  |  |\n| ON/OFF cooling mode- 1 intervention point with warning and maximum alarm management | 9100AB13 | 9900AB13 |\n| ON/OFF-2 intervention points | 9100AB14 | 9900AB14 |\n| Subcooling fixed temperature with V800 driver through IO | 9100AB15 | 9900AB15 |\n| Subcooling floating setpoint with V910 driver through LAN (RS485 EXP) | 9100AB16 | 9900AB16 |\n\n.DAT download on EWCM requires USB Copy Card  \nOnce you have downloaded the file on EWCM EO, remove the USB Copy Card and it will reset automatically  \nEliwell Controls s.r.l.  \nVia dell’Industria, 15 • Zona Industriale Paludi • 32010 Pieve d’Alpago (BL) ITALY  \nTelephone +39 0437 986 111 • Fax +39 0437 989 066  \nTechnical Customer Support: Technical helpline: +39 0437 986 300 • E-mail [techsuppeliwell@invensys.com](techsuppeliwell@invensys.com)[ ](techsuppeliwell@invensys.com)Sales: T: +39 0437 986 100 (Italy)• +39 0437 986 200 (other countries)• E-mail [saleseliwell@invensys.com](saleseliwell@invensys.com)[ ](saleseliwell@invensys.com)[www.eliwell.com](www.eliwell.com)  \nEWCM   \nEWCM EO Applications Index rel. 19.12.12  \nSecured Applications Registered Users Applications available for Level 1 users  \nNot yet registered? 􀃆Register Registered Users 􀃆Login  \nEliwell Controls s.r.l.  \nVia dell’Industria, 15 • Zona Industriale Paludi • 32010 Pieve d’Alpago (BL) ITALY  \nTelephone +39 0437 986 111 • Fax +39 0437 989 066  \nTechnical Customer Support: Technical helpline: +39 0437 986 300 • E-mail [techsuppeliwell@invensys.com](techsuppeliwell@invensys.com)[ ](techsuppeliwell@invensys.com)Sales: T: +39 0437 986 100 (Italy)• +39 0437 986 200 (other countries)• E-mail [saleseliwell@invensys.com](saleseliwell@invensys.com)[ ](saleseliwell@invensys.com)[www.eliwell.com](www.eliwell.com)  \npage 2","cbCaidObyyt4JBsm","https://ap.wps.com/l/cbCaidObyyt4JBsm","pdf",152513,"English","# Applications Index\n## .DAT Applications and Models\n## Download and Reset Notes","[{\"question\":\"What is the purpose of the EWCM EO Applications Index?\",\"answer\":\"It lists EWCM EO .DAT applications provided by Eliwell for registered users and shows how each application maps to EWCM EO 9100 and 9900 models.\"},{\"question\":\"Do these applications change thresholds, alarm, or safety times?\",\"answer\":\"No. The index states that the applications do not modify threshold adjustments, alarm times, or safety times.\"},{\"question\":\"How does downloading EWCM EO .DAT applications work with a USB Copy Card?\",\"answer\":\"Download the file on EWCM using the USB Copy Card, then remove the card; the system resets automatically.\"}]","EWCM EO Applications Index - rel. 19.12.12 | PDF",1789636244]