[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-515998-105":59,"doc-detail-515998-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","evapco-lste-bulletin-313-e","EVAPCO LSTE Bulletin 313-E","","EVAPCO Model LSTE forced draft centrifugal cooling towers deliver thermal performance across a wide nominal capacity range and emphasize performance-focused design. The bulletin highlights IBC compliance and CTI-ECC certification and outlines quality driven by ongoing R&D since 1976. It details construction features such as easy field assembly, drift eliminators, PVC spray distribution, EVAPAK fill, and dry-stream fan motor systems that support low noise, indoor installation, blow-thru corrosion resistance, and modular low installed costs.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/evapco-lste-bulletin-313-e/515998/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/evapco-lste-bulletin-313-e/515998.png","ImageObject",300,407,{"name":92,"@type":93},"Bintang","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-01","2026-10-06",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What certifications and compliance does the EVAPCO LSTE emphasize?","Question",{"text":112,"@type":113},"The bulletin states the new and improved EVAPCO Model LSTE features IBC Compliance in addition to CTI-ECC Certification.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the cooling process work in the tower?",{"text":117,"@type":113},"Warm water is pumped to the top distribution system, sprayed over wet-deck fill, while air is forced upward by centrifugal fans. A portion of water evaporates to remove heat, and cooled water returns to the basin.",{"name":119,"@type":110,"acceptedAnswer":120},"What design features support easy assembly and reduced maintenance?",{"text":121,"@type":113},"The document highlights easy field assembly with fewer fasteners and self-guiding channels for field seams, along with dry-stream fan motors that allow normal outside maintenance and access by removing screens.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},515998,1791451656,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":4},962085564381,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Bulletin 313-E Metric  \nL OW S O U N D  \nF O R C E D D RA FT , C O U NT E R F L OW C O O L I N G T OW E R S  \nThermal Performance from 145 to 5930 kW Nominal Capacity  \nD EL I VE R I N G Q UA L I TY   FO C US E D O N PE R FE C TI O N !  \nMark owned by the Cooling Technology Institute  \nThe new & improved EVAPCO Model LSTE forced draft centrifugal cooling towersnow feature IBC Compliance in addition to CTI-ECC Certification.  \nThese features reinforce EVAPCO’s position as the leading manufacturer of forced draft evaporative cooling equipment.  \nS ince its founding in 1976 ,  \nEVAPCO , Inc . has become a  \nworld-wide leader in supplying quality cooling equipment for thousands of customers in both the commercia l and industrial markets.  \nEVAPCO’s success has been the result of a continual commitment to product improvement, quality workmanship anda dedication to providing unparalleled service.  \nOur emphasis on research and development has led to many product innovations – a hallmark of EVAPCO through the years.  \nThe ongoing R & D Program enables EVAPCO to provide the most advanced products in the industry – technology for the future, available today.  \nEVAPCO products are manufactured on five continents around the world and distributed through hundreds of factory authorized sales representatives.  \nZ-725 Heavy Mill Galvanized Steel Construction  \n(Stainless steel available as an affordable option)  \nEVAPCO  \nothers  \nEasy Field Assembly  \n• Ensures easy assembly and fewer fasteners.  \n• Incorporates self-guiding channels to guide the casing section into position improving the quality of the field seam.  \nStainless Steel  \nStrainer  \n• Resists corrosion better than other materials  \nClean Pan Design  \n• Sloped design allows water to drain completely from cold water basin.  \n• Easier removal of dirt and debris.  \n©2010 EVAPCO Europe  \n2  \nE A S Y S O L U T I O N S , B E T T E R C H O I C E S !  \nDESIGN AND CONSTRUCTION FEATURES  \nFully Integrated Water Saver Drift Eliminators  \n• New patented design reduces drift rate to \u003C 0.001%  \n• Saves water and reduces water treatment cost  \n• Greater structural integrity vs. old style blade-type  \n• Eliminators now integrated within casing section for easy mounting of ductwork, discharge hood and attenuation  \n• Drift rate certifications Eurovent OM-14-2009  \nPVC Spray Distribution Header  \n• Nozzles are threaded into the header to ensure proper orientation.  \n• Fixed position nozzles require little maintenance.  \n• Large orifice nozzle with integral sludge ring to prevent clogging.  \nExclusive EVAPAK® fill  \n• Provides the most efficient thermal performance per plan area  \n• Suitable for use as a working platform  \nTotally Enclosed Fan Motors & Superior Drive System  \n• Assures long life  \n• Located in dry, incoming air-stream, allowing normal maintenance to be done from the outside of the unit  \n• If required, motor can be easily removed  \n• One piece fan shaft  \n• Belt tensioning and bearing lubrication can be performed from outside the unit  \n• Motor is fully accessible by removing one inlet screen  \n† Mark owned by the Cooling Technology Institute  \n3  \n\n| E C C-C T I |\n| --- |\n| I B C |\n| SOUND |\n| APPL ICAT IONS |\n| O PT ION S |\n| D E S IGN |\n\nD E S IGN  \nE A S Y S O L U T I O N S , B E T T E R C H O I C E S !  \nD E S I G N F E AT U R E S  \nPrinciple of Operation  \nWarm water from the heat source is pumped to the water distribution system at the top of the tower. The water is then distributed over the wet deck fill by means of large orifice nozzles. Simultaneously, air is forced-up through the fill section via centrifugal fans. A small portion of the water is evaporated, which removes the heat from the remaining water. The warm moist air is forced to the top of the cooling tower and discharged to the atmosphere. The cooled water then drains to the basin at the bottom of the tower where it is returned to the heat source.  \nHot Saturated Discharge Air  \nDrift Eliminators  \nCooled Water","cbCaihjCHlMz1373","https://ap.wps.com/l/cbCaihjCHlMz1373","pdf",3059265,32,"English","# Metric Low Sound Forced Draft Cooling Towers\n## Thermal Performance and Capacity Range\n## Design and Construction Features\n## Principle of Operation\n## Application Versatility and Installation Options\n## Very Quiet Operation\n## Indoor Installation and Blow-Thru Construction\n## Low Installed Costs","[{\"question\":\"What certifications and compliance does the EVAPCO LSTE emphasize?\",\"answer\":\"The bulletin states the new and improved EVAPCO Model LSTE features IBC Compliance in addition to CTI-ECC Certification.\"},{\"question\":\"How does the cooling process work in the tower?\",\"answer\":\"Warm water is pumped to the top distribution system, sprayed over wet-deck fill, while air is forced upward by centrifugal fans. A portion of water evaporates to remove heat, and cooled water returns to the basin.\"},{\"question\":\"What design features support easy assembly and reduced maintenance?\",\"answer\":\"The document highlights easy field assembly with fewer fasteners and self-guiding channels for field seams, along with dry-stream fan motors that allow normal outside maintenance and access by removing screens.\"}]","EVAPCO LSTE Bulletin 313-E | PDF",1791324260,81]