[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-398175-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-398175-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","evaluation-of-three-new-fit-test-protocols-for-use-with-the-tsi-portacount","Evaluation of Three New Fit Test Protocols for Use - with the TSI PortaCount","","This paper evaluates three new quantitative respirator fit test protocols using the TSI PortaCount system, focusing on reducing total OSHA 8-exercise fit test time. Results from thirty subjects and 140 fit tests across half and full facepiece respirators are compared against ANSI Z88.10-2001 (Annex A2) acceptance criteria. Protocols shorten in-facepiece sampling and/or eliminate early exercise maneuvers, achieving high sensitivity (0.97–1.00) and strong correlation (0.956–0.988) with the reference method.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/evaluation-of-three-new-fit-test-protocols-for-use-with-the-tsi-portacount/398175/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/evaluation-of-three-new-fit-test-protocols-for-use-with-the-tsi-portacount/398175.png","ImageObject",300,407,{"name":42,"@type":43},"Jake","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-09-27",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What objective does the study address for TSI PortaCount fit testing?","Question",{"text":63,"@type":64},"The study investigates whether shortening in-mask sampling time and removing one or more OSHA exercises produces equivalent quantitative fit test results using the TSI PortaCount Plus Model 8020 system.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How do protocol #2 and protocol #3 reduce total fit test time?",{"text":68,"@type":64},"Protocol #2 reduces in-facepiece sampling time from 40 to 20 seconds, changing each exercise maneuver from 60 to 40 seconds. Protocol #3 keeps the same 40-second exercise time but further reduces total test time by eliminating the first two exercise maneuvers.",{"name":70,"@type":61,"acceptedAnswer":71},"How do the new protocols perform relative to ANSI Z88.10-2001 acceptance criteria?",{"text":72,"@type":64},"All three protocols show strong agreement with the reference fit test method, with correlation coefficients of 0.956, 0.988, and 0.982. Protocols #2 and #3 also exceed ANSI acceptance criteria, with sensitivities of 0.97 and 1.00 respectively.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},398175,1791263715,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":123,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":144,"preview_page_count":33,"preview_urls":145},962084928904,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Evaluation of Three New Fit Test Protocols for Use  \nwith the TSI PortaCount  \nRoy T. McKay and Jeff Bradley  \nDept. of Environmental Health, University of Cincinnati, 3223 Eden Avenue,  \nCincinnati, OH 45267; [E-mail: Roy@DrMcKay.com](E-mail: Roy@DrMcKay.com)  \nABSTRACT  \nThPisortsatuCyunitnvesquaigattitaie thfitreteestnewsystqeumantiEivhftithesthinege nproewtopcolsrotocelssneasddfeosirgunse twoihhohteen TStheI time required to perform an OSHA 8-exercise quantitative fit test. Results were compared to the acceptance criteria established by ANSI Z88 .10-2001 (Annex A2: Criteria for Evaluating Fit Test Methods) . A total of thirty subjects conducted 140 fit tests with a variety of good and poor fitting half and full facepiece respirators. Decreasing total fit test time was accomplished by decreasing the time required to obtain an in-facepiece sample and/or by eliminating exercise maneuvers. Two of the protocols in this study (protocols \\#2 and \\#3) utilized a shortened in-facepiece sampling time to reduce the length of each exercise maneuver from 60 to 40 seconds. This was achieved by reducing the in-facepiece sampling time from 40 to 20 seconds, while keeping ambient sample and purge times unchanged. Test sensitivity for protocol \\#2 was 0.97 when the reference method pass/fail criterion was set to either 100 or 500. This exceeds the ANSI recommendation for accepting a new fit test method. Protocol \\#3 used the same exercise time as protocol \\#2 (40 seconds), however, the total test time was further reduced by eliminating the first two exercise maneuvers while using a more stringent pass fail criterion of 200 and 1,000 (two times the OSHA requirement) . Results for protocol \\#3 also exceeded the ANSI criterion for acceptance of a new fit test method. Test sensitivity for protocol \\#3 was 1.00. All three of the new test protocols were highly correlated with the reference fit test method. Correlation coefficients for protocols \\#1, \\#2, and \\#3 were 0.956, 0.988, and 0.982, respectively. This study demonstrated that reducing the exercise time with the TSI PortaCount had little effect on the ability of this instrumentation to identify poorly fitting respirators. In addition, eliminating the first two exercise maneuvers from the 1998 OSHA 8-exercise protocol in conjunction with doubling of the pass/fail criterion not only provides a significantly faster fit test protocol, but provides a more conservative fit test for quantitative respirator fit testing.  \nKeywords: Respirator fit testing, quantitative fit testing, respirators, TSI PortaCount, respiratory protection, fit factor  \nINTRODUCTION  \nI  \nn the United States, the Occupational Safety and Health Administration (OSHA) requires fit testing for all tight fitting respirators that are required to be worn (OSHA 1998) . This includes negative and positive  \npressure elastomeric and filtering facepiece respirators. This standard also specifies the number, type, and length of different breathing and head movement exercises to be used for fit testing. The purpose of these exercises is to challenge the face seal by simulating the many different breathing patterns and head movements that may occur during respirator use. During qualitative and quantitative fit testing (with  \naerosol-based systems), the length of each exercise for OSHA accepted protocols are one minute, with exception to an additional 15-second grimace maneuver for some quantitative fit test protocols. One purpose of fit testing is to verify mask size and donning competence by identifying the presence or absence of significant leakage into the facepiece. These leaks, are present initially or induced. Induced leak sites come in two basic types, those which are transient and occur during the active movement of the exercise, such as turning the head side-to-side, and those that are progressive (i.e. , influenced by the preceding exercise movements) . Currently, there is no scientific basis to support a one-minute exercise ","cbCaii2mXCII79vA","https://ap.wps.com/l/cbCaii2mXCII79vA","pdf",102265,"English","# Abstract\n# Introduction\n# Methods","[{\"question\":\"What objective does the study address for TSI PortaCount fit testing?\",\"answer\":\"The study investigates whether shortening in-mask sampling time and removing one or more OSHA exercises produces equivalent quantitative fit test results using the TSI PortaCount Plus Model 8020 system.\"},{\"question\":\"How do protocol #2 and protocol #3 reduce total fit test time?\",\"answer\":\"Protocol #2 reduces in-facepiece sampling time from 40 to 20 seconds, changing each exercise maneuver from 60 to 40 seconds. Protocol #3 keeps the same 40-second exercise time but further reduces total test time by eliminating the first two exercise maneuvers.\"},{\"question\":\"How do the new protocols perform relative to ANSI Z88.10-2001 acceptance criteria?\",\"answer\":\"All three protocols show strong agreement with the reference fit test method, with correlation coefficients of 0.956, 0.988, and 0.982. Protocols #2 and #3 also exceed ANSI acceptance criteria, with sensitivities of 0.97 and 1.00 respectively.\"}]","Evaluation of Three New Fit Test Protocols for Use - with the TSI PortaCount | PDF",1790472951,25,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/e4a5952fcfadf4e42aa34ef5ffbe3dc3.webp",983,1272,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/7640ed3b26be1d65eb97777a8c3073df.webp",982,1270,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/b48f237718492349d5415fdc1a9297c8.webp",981,1269,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/88ad1c6d2b53c3518574b63dd47ff11e.webp",980,1268]