[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-467926-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-467926-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","evaluation-of-the-uncertainty-in-calculating-nanodosimetric-quantities-due-to-the-use-of-different-interaction-cross-sections-in-monte-carlo-track-structure-codes","Evaluation of the uncertainty in calculating nanodosimetric quantities due to the use of different interaction cross sections in Monte Carlo track structure codes","","Biological effects induced by ionizing radiation vary with the microscopic patterns of interactions. Nanodosimetry links these variations to radiation behavior within nanometer-scale volumes by combining experiments with Monte Carlo track structure (MCTS) simulations. This multi-code study tests low-energy electrons (20–10,000 eV) across seven MCTS codes and shows that discrepancies in predicted nanodosimetric quantities arise mainly from differences in total interaction cross sections. Replacing each code’s cross sections with a common averaged dataset sharply reduces inter-code variability, and DNA damage simulations demonstrate that cross-section choices can shift predicted biological outcomes, including double-strand break yields.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/evaluation-of-the-uncertainty-in-calculating-nanodosimetric-quantities-due-to-the-use-of-different-interaction-cross-sections-in-monte-carlo-track-structure-codes/467926/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/evaluation-of-the-uncertainty-in-calculating-nanodosimetric-quantities-due-to-the-use-of-different-interaction-cross-sections-in-monte-carlo-track-structure-codes/467926.png","ImageObject",300,407,{"name":42,"@type":43},"MrHarris58","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-16","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",7,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What causes differences between nanodosimetric predictions across Monte Carlo track structure codes?","Question",{"text":63,"@type":64},"The study finds that inter-code variability is mainly driven by differences in assumptions about total interaction cross sections used in each code.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How were nanodosimetric quantities evaluated in this study?",{"text":68,"@type":64},"Ionization cluster size distributions and derived nanodosimetric parameters were simulated for low-energy electrons using seven MCTS codes in liquid water as a tissue surrogate.",{"name":70,"@type":61,"acceptedAnswer":71},"What was the impact of replacing code-specific cross sections with a common averaged dataset?",{"text":72,"@type":64},"Using a shared averaged cross-section dataset substantially reduced inter-code variability at the lowest energies and increased mechanistic confidence; DNA damage simulations showed up to ~15% higher double-strand break yield under the averaged dataset.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},467926,1791348557,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},687212988360,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","OPEN ACCESS  \nCitation: Villagrasa C, Baiocco G, Chaoui Z-E-A, Dingfelder M, Incerti S, Kundrát P, et al. (2026) Evaluation of the uncertainty in calculating nanodosimetric quantities due to the use of different interaction cross sections in Monte Carlo track structure codes. PLoS One 21(1):  \ne0340500. [https://doi.org/10.1371/journal](https://doi.org/10.1371/journal). pone.0340500  \nEditor: Cebastien Joel Guembou Shouop, Cameroon National Radiation Protection Agency, CAMEROON  \nReceived: February 22, 2025  \nAccepted: December 22, 2025  \nPublished: January 9, 2026  \nCopyright: © 2026 Villagrasa et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.  \nData availability statement: All relevant data are within the manuscript and its Supporting  Information files. Values of the common  \nRESEARCH ARTICLE  \nEvaluation of the uncertainty in calculating nanodosimetric quantities due to the use of different interaction cross sections in Monte Carlo track structure codes  \nCarmen Villagrasa1*, Giorgio Baiocco2, Zine-El-Abidine Chaoui3,  \nMichael Dingfelder4, Sébastien Incerti5, Pavel Kundrát6, Ioanna Kyriakou7,  \nYusuke Matsuya8,9, Takeshi Kai9, Alessio Parisi10, Yann Perrot1, Marcin Pietrzak 11,12, Jan Schuemann13, Hans Rabus14  \n1 Autorité de sÛreté nucléaire et de radioprotection (ASNR), PSE-SANTE/SDOS/LDRI, F-92260, Fontenay aux Roses, France, 2 Radiation Biophysics and Radiobiology Group, A. Volta Physics  \nDepartment, University of Pavia, Pavia, Italy, 3 Physics Department, Faculty of Sciences, Ferhat  \nAbbas University Setif1 . Algeria, 4 Department of Physics, East Carolina University, Greenville, North Carolina, United States of America, 5 Universit de Bordeaux, CNRS, LP2I, UMR, Gradignan, France, 6 Department of Radiation Dosimetry, Nuclear Physics Institute of the CAS, Na Truhlářce, Czech Republic, 7 Medical Physics Laboratory, Department of Medicine, University of Ioannina, Ioannina, Greece, 8 Faculty of Health Sciences, Hokkaido University, Sapporo, Hokkaido , Japan, 9 Nuclear Science and Engineering Center, Japan Atomic Energy Agency, 2-4 Shirane Shirakata, Tokai, Ibaraki , Japan, 10 Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida, United States of America, 11 Cyclotron Centre Bronowice, The Henryk Niewodniczanski Institute of Nuclear Physics Polish Academy of Sciences, Radzikowskiego, Krakow, Poland, 12 Radiological Metrology and Biomedical Physics Division, Nuclear Equipment and Technology Department, National Centre for Nuclear Research, Otwock-Swierk, Poland, 13 Department of Radiation Oncology, Massachusetts General Hospital & Harvard Medical School, Boston, Massachusetts, United States of America, 14 Physikalisch-Technische Bundesanstalt (PTB), Abbestrasse 2-12, Berlin, Germany  \n* [carmen.villagrasa@asnr.fr](carmen.villagrasa@asnr.fr)  \nAbstract  \nBiological effects induced by diverse types of ionizing radiation are known to show important variations. Nanodosimetry is suitable for studying the link between these variations and the patterns of radiation interactions within nanometer-scale volumes, using experimental techniques complemented by Monte Carlo track structure (MCTS) simulations. However, predicted nanodosimetric quantities differ among MCTS codes, primarily because each code employs distinct molecular-scale particle interaction models. This multi-code study examines these variations for low-energy electrons (20–10,000 eV), which play a critical role in energy deposition and biological effects by virtually all types of ionizing radiation. Specifically, the hypothesis tested in this work is that inter-code variability in nanodosimetry results is mainly caused by differences in assumptions regarding total interaction cross sections. Ionization cluster size distributions and derived nanodosimetric parame","cbCaiflUC8NR141D","https://ap.wps.com/l/cbCaiflUC8NR141D","pdf",1968417,26,"English","# Abstract\n# Introduction\n# Methods and multi-code evaluation\n# Sensitivity test with DNA damage simulations\n# Data availability and supporting information\n# Funding and competing interests","[{\"question\":\"What causes differences between nanodosimetric predictions across Monte Carlo track structure codes?\",\"answer\":\"The study finds that inter-code variability is mainly driven by differences in assumptions about total interaction cross sections used in each code.\"},{\"question\":\"How were nanodosimetric quantities evaluated in this study?\",\"answer\":\"Ionization cluster size distributions and derived nanodosimetric parameters were simulated for low-energy electrons using seven MCTS codes in liquid water as a tissue surrogate.\"},{\"question\":\"What was the impact of replacing code-specific cross sections with a common averaged dataset?\",\"answer\":\"Using a shared averaged cross-section dataset substantially reduced inter-code variability at the lowest energies and increased mechanistic confidence; DNA damage simulations showed up to ~15% higher double-strand break yield under the averaged dataset.\"}]","Evaluation of the uncertainty in calculating nanodosimetric quantities due to the use of different interaction cross sections in Monte Carlo track structure codes | PDF",1790773558,66,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/82a93a79b0c6d3175f11b869430f8c2c.webp",983,1272,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c6accdfc83d78b077b6600cab8f562a2.webp",982,1270,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/3d28bc37a1e80112fb48ee06502b20f8.webp",981,1269,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c0865f62a7572a90c7e67191bc04d4cb.webp",980,1268]