[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-466494-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-466494-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","evaluation-of-selected-properties-of-ti-coatings-deposited-on-med610-for-medical-applications","Evaluation of Selected Properties of Ti Coatings Deposited on MED610 for Medical Applications","","The study develops and evaluates MED610 coated with a thin titanium (Ti) layer deposited by physical vapour deposition (PVD) for medical applications. The coating aims to enhance biocompatibility and functional performance, with emphasis on tribological resistance. Unpolished and polished samples were compared to isolate the effect of surface topography. Analyses include surface geometry, contact angle, and tribological behavior in artificial saliva at neutral pH, simulating oral conditions. Results show reduced roughness by 20–45%, good adhesion, higher friction (~31%), and reduced volumetric wear (up to 75% without coating; 44% with Ti).",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/evaluation-of-selected-properties-of-ti-coatings-deposited-on-med610-for-medical-applications/466494/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/evaluation-of-selected-properties-of-ti-coatings-deposited-on-med610-for-medical-applications/466494.png","ImageObject",300,407,{"name":42,"@type":43},"supergirl","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-12","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",9,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What was the objective of the study on Ti coatings for MED610?","Question",{"text":63,"@type":64},"To develop and evaluate MED610 coated with a thin titanium layer deposited by PVD for medical applications, focusing on biocompatibility and functional properties such as tribological resistance.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How were the samples prepared for assessing surface topography effects?",{"text":68,"@type":64},"Two groups were prepared: unpolished and polished. The Ti layer was applied to both groups to evaluate how surface topography influences functional performance.",{"name":70,"@type":61,"acceptedAnswer":71},"What tribological tests were conducted in the study, and what environment was used?",{"text":72,"@type":64},"Surface geometry, contact angle, and tribological properties were analyzed in artificial saliva at neutral pH to simulate oral cavity conditions.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},466494,1790829198,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},962088121634,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Article  \nEvaluation of Selected Properties of Ti Coatings Deposited on MED610 for Medical Applications  \nKatarzyna Piotrowska , Joanna Kowalczyk  and Tomasz Kozior *  \nAcademic Editor: FernãoD. Magalhães  \nReceived: 18 November 2025  \nRevised: 19 December 2025  \nAccepted: 21 December 2025  \nPublished: 23 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \nFaculty of Mechatronics and Mechanical Engineering, Kielce University of Technology, 25-314 Kielce, Poland; [kpawelec@tu.kielce.pl](kpawelec@tu.kielce.pl) (K.P.); [jkowalczyk@tu.kielce.pl](jkowalczyk@tu.kielce.pl) (J.K.)  \n* Correspondence: [tkozior@tu.kielce.pl](tkozior@tu.kielce.pl)  \nAbstract  \nThe aim of the study was to develop and evaluate the properties of MED610 material coated with a thin titanium (Ti) layer deposited by physical vapour deposition (PVD) for medical applications. The coating was designed to improve biocompatibility and selected functional characteristics, such as the material’s tribological resistance. Two groups of samples—unpolished and polished—were prepared to enable an assessment of the influence of surface topography on functional performance. A titanium layer was applied to both groups, followed by an analysis of the surface geometric structure, contact angle, and tribological properties in an artificial saliva environment with neutral pH, simulating oral cavity conditions. The results of these investigations allowed for a comprehensive assessment of the influence of surface topography and the presence of a Ti coating on the functional properties of MED610, a material approved for contact with soft tissues. The findings confirmed that the application of a titanium coating favourably affected the structure and durability of the material—the coating reduced surface roughness by 20–45% and exhibited good adhesion to the substrate. The polishing and coating processes significantly altered the tribological properties: they increased the coefficient of friction by approximately 31% while simultaneously reducing volumetric wear by up to 75% for uncoated samples and by 44% for samples with a Ti coating.  \nKeywords: 3D printing; MED610; PJM; wettability; friction; wear  \n1. Introduction  \nThe development of 3D printing technologies represents one of the key directions of modern manufacturing engineering, enabling the fabrication of components with complex geometries that are unattainable using conventional production methods. As knowledge of 3D printing technologies continues to expand, the number of their practical applications is also steadily increasing [1] .  \nAdditive manufacturing is currently used, among others, in the automotive and aerospace industries [2,3], as well as in medicine [4,5], where its design flexibility enables applications across numerous specialties, including surgery, dentistry, and orthopaedics. Such products include both ready-to-use components and highly personalised anatomical models, such as implants [6,7], surgical guides [8,9], preoperative simulations [7,10], biodegradable screws [11,12], functional prostheses and orthoses [1], as well as drugdelivery systems [13] . Moreover, MED610 can be used as an acrylic substitute in the production of replacement inserts for ocular plaque brachytherapy applicators [14], as well as for personalised nasoalveolar moulding devices designed for preoperative unilateral and  \nbilateral cleft lip and palate treatment in infants [15] . It is also employed in the fabrication of customised mouthpieces for patients undergoing head and neck radiotherapy [16] . Consequently, intensive research is being conducted on new materials [4] that are characterised by biocompatibility [1,4] and good printability [1] .  \nAn example of a polymer used in medical applications is MED610. It is a biocompatible photopolymer employed in the Poly","cbCaiprwKPSLQ9FJ","https://ap.wps.com/l/cbCaiprwKPSLQ9FJ","pdf",5054664,17,"English","# Introduction\n## MED610 in medical additive manufacturing\n## Tribological background and related studies","[{\"question\":\"What was the objective of the study on Ti coatings for MED610?\",\"answer\":\"To develop and evaluate MED610 coated with a thin titanium layer deposited by PVD for medical applications, focusing on biocompatibility and functional properties such as tribological resistance.\"},{\"question\":\"How were the samples prepared for assessing surface topography effects?\",\"answer\":\"Two groups were prepared: unpolished and polished. The Ti layer was applied to both groups to evaluate how surface topography influences functional performance.\"},{\"question\":\"What tribological tests were conducted in the study, and what environment was used?\",\"answer\":\"Surface geometry, contact angle, and tribological properties were analyzed in artificial saliva at neutral pH to simulate oral cavity conditions.\"}]","Evaluation of Selected Properties of Ti Coatings Deposited on MED610 for Medical Applications | PDF",1790771346,43,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ea178fda917a760ca1ff9e288713c33e.webp",983,1390,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/cbc2911b42e497599a8fa66cff030bc6.webp",982,1388,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/8421786e44ee766dc29362040b3918cb.webp",981,1387,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/fc8b9707d7761c8a77350aec5a93a016.webp",980,1385]