[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-339920-105":59,"doc-detail-339920-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","evaluation-of-prostate-cancer-detection-using-micro-ultrasound-versus-mri-through-co-registration-to-whole-mount-pathology","Evaluation of prostate cancer detection using micro‑ultrasound versus MRI through co‑registration to whole‑mount pathology","","Micro-ultrasound is explored as a low-cost alternative to multi-parametric MRI for imaging prostate cancer, yet reliable validation against whole-mount pathology remains limited. The study develops a multi-step co-registration workflow linking micro-ultrasound and MRI to whole-mount pathology, including micro-ultrasound reconstruction, 3D landmark registration to MRI, and 2D capsule registration to whole-mount slides. The pipeline achieves a registration error of 3.90 ± 0.11 mm and supports a reader study in 15 prostatectomy patients comparing diagnostic accuracy between modalities.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/evaluation-of-prostate-cancer-detection-using-micro-ultrasound-versus-mri-through-co-registration-to-whole-mount-pathology/339920/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/evaluation-of-prostate-cancer-detection-using-micro-ultrasound-versus-mri-through-co-registration-to-whole-mount-pathology/339920.png","ImageObject",300,407,{"name":92,"@type":93},"Asher","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04","2026-09-21",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",13,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What problem does the study address in micro-ultrasound validation?","Question",{"text":113,"@type":114},"It targets the lack of robust validation by comparing micro-ultrasound imaging with whole-mount pathology, which is difficult to correlate due to probe design and tissue deformation.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How is micro-ultrasound co-registered with MRI and whole-mount pathology?",{"text":118,"@type":114},"The method uses a three-step process: micro-ultrasound image reconstruction, 3D landmark registration of micro-ultrasound to MRI, and 2D capsule registration of MRI to whole-mount pathology.",{"name":120,"@type":111,"acceptedAnswer":121},"What were the key diagnostic comparisons between micro-ultrasound and MRI?",{"text":122,"@type":114},"Micro-ultrasound showed equivalent performance for index lesion detection compared with retrospective MRI review, but increased detection of tumor extent, while MRI prospectively reviewed improved false positive ROI rates.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},339920,1790536309,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},687197207639,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nEvaluation of prostate cancer detection using micro‑ultrasound versus MRI through co‑registration to whole‑mount pathology  \nJake Pensa1,2,3*, Wayne Brisbane2, Adam Kinnaird4, David Kuppermann2,  \nGriffith Hughes1,2,3, Derrick Ushko4, Alan Priester2,3, Samantha Gonzalez2, Robert Reiter2, Arnold Chin2, Anthony Sisk2, Ely Felker2, Leonard Marks2 & Rory Geoghegan2,3  \nMicro‑ultrasound has recently been introduced as a low‑cost alternative to multi‑parametric MRI for imaging prostate cancer. Early clinical studies have demonstrated promising results; however, robust validation via comparison with whole‑mount pathology has yet to be achieved. Due to micro‑ ultrasound probe design and tissue deformation during scanning, it is difficult to accurately correlate micro‑ultrasound imaging planes with ground truth whole‑mount pathology slides. In this study, we developed a multi‑step methodology to co‑register micro‑ultrasound and MRIto whole‑mount pathology. The three‑step process had a registration error of 3.90 ± 0.11 mm and consists of: (1) micro‑ ultrasound image reconstruction,(2) 3D landmark registration of micro‑ultrasound to MRI, and (3) 2D capsule registration of MRIto whole‑mount pathology. This process was then used in a preliminary reader study to compare the diagnostic accuracy of micro‑ultrasound and MRI in 15 patients who underwent radical prostatectomy for prostate cancer. Micro‑ultrasound was found to have equivalent performance to retrospective MRI review for index lesion detection (91.7% vs. 80%), while demonstrating an increased detection of tumor extent (52.5% vs. 36.7%) with similar false positive regions‑of‑interest (38.3% vs. 40.8%) . Prospective MRI review had reduced detection of index lesions (73.3%) and tumor extent (18.9%) but improved false positive regions‑of‑interest (22.7%) relative to micro‑ultrasound and retrospective MRI. Further evaluation is needed with a larger sample size.  \nKeywords Co-registration, Image reconstruction, Micro-ultrasound, MRI, Prostate cancer, Whole-mount pathology  \nProstate cancer is the most common malignancy and the second leading cause of cancer death in men in the United States, with an estimated 300,000 new cases and 35,000 deaths in 20241. Whereas clinically significant (Gleason grade 3 + 4 or higher) prostate cancer can be deadly, patients with low grade clinically insignificant prostate cancer (Gleason grade 3 + 3 or lower) have less than a 2% risk of cancer specific mortality 10 years after diagnosis2–4. Consequently, accurate cancer staging is vital for disease management as overtreatment of low grade cancer can result in significant decreases in patient quality of life and increased healthcare expenditures, whereas undertreatment of aggressive disease can be fatal2.  \nThe conventional diagnostic pathway utilizes an ultrasound (US) guided systematic biopsy following an elevated value on a prostate-specific antigen (PSA) screening test5. While US allows for general gland visualization, it has poor sensitivity and specificity for tumor detection6. In contrast, multi-parametric magnetic resonance imaging (mpMRI) has high sensitivity (86–92%) and specificity (60–83%) for identification of prostate cancer index lesions7–9. Index lesions are defined as the largest and most aggressive tumor in a prostate, the size and grade of which are often used to decide the appropriate treatment pathway10. Consequently, current recommendations include an MRI-guided biopsy or more commonly: MR-US fused biopsy11, 12. For fusion biopsies, a pre-biopsy mpMRI identified region-of-interest (ROI) is fused to a live US scan allowing for US guided targeted biopsy of an MRI ROI13. This targeted approach improves cancer detection, however, mpMRI is resource intensive, has  \n1Department of Bioengineering, University of California Los Angeles, Los Angeles, USA. 2Department of Urology, University of California Los Angeles, ","cbCainrYTEP66ZQA","https://ap.wps.com/l/cbCainrYTEP66ZQA","pdf",4684077,14,"English","# Study overview\n## Co-registration methodology\n## Reader study design and results\n## Clinical background and rationale\n## Current diagnostic pathways and limitations\n## Micro-ultrasound imaging principles","[{\"question\":\"What problem does the study address in micro-ultrasound validation?\",\"answer\":\"It targets the lack of robust validation by comparing micro-ultrasound imaging with whole-mount pathology, which is difficult to correlate due to probe design and tissue deformation.\"},{\"question\":\"How is micro-ultrasound co-registered with MRI and whole-mount pathology?\",\"answer\":\"The method uses a three-step process: micro-ultrasound image reconstruction, 3D landmark registration of micro-ultrasound to MRI, and 2D capsule registration of MRI to whole-mount pathology.\"},{\"question\":\"What were the key diagnostic comparisons between micro-ultrasound and MRI?\",\"answer\":\"Micro-ultrasound showed equivalent performance for index lesion detection compared with retrospective MRI review, but increased detection of tumor extent, while MRI prospectively reviewed improved false positive ROI rates.\"}]","Evaluation of prostate cancer detection using micro‑ultrasound versus MRI through co‑registration to whole‑mount pathology | PDF",1790033096,35,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/8be5ae7d91c6493f86dab469aaeb9c51.webp",983,1291,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/f0c4b962d139e5f10557bf521e364905.webp",982,1290,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/3fea92b679beb5c75451e79976db0150.webp",981,1289,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/5c80ded22c3c0f2dee1f3905e2f98124.webp",980,1287]