[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-460205-105":59,"doc-detail-460205-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","evaluation-of-diagnostic-visibility-in-cbct-images-with-prosthodontic-crown-induced-artifacts-retrospective-cbct-analysis","Evaluation of Diagnostic Visibility in CBCT Images with Prosthodontic Crown-Induced Artifacts - Retrospective CBCT Analysis","","Background: CBCT is widely used in dental diagnostics, but crown-related artifacts can diminish diagnostic clarity and obscure critical hard-tissue details. This retrospective analysis evaluated how prosthodontic crown materials—metal, porcelain-fused-to-metal (PFM), and zirconia—affect CBCT visibility. Materials and Methods: Archived CBCT scans were scored for diagnostic visibility of key landmarks using the DVS (0–4) by two blinded observers. Results and Conclusion: Metal crowns produced the greatest distortion, PFM ranked intermediate, and zirconia preserved landmark visibility with statistically significant group differences and strong interobserver agreement.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/evaluation-of-diagnostic-visibility-in-cbct-images-with-prosthodontic-crown-induced-artifacts-retrospective-cbct-analysis/460205/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/evaluation-of-diagnostic-visibility-in-cbct-images-with-prosthodontic-crown-induced-artifacts-retrospective-cbct-analysis/460205.png","ImageObject",300,407,{"name":92,"@type":93},"Rainbow Cat","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-29","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Which crown materials were compared for their effect on CBCT diagnostic visibility?","Question",{"text":112,"@type":113},"The study compared metal crowns, porcelain-fused-to-metal (PFM) crowns, and zirconia crowns using archived CBCT scans.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What was the diagnostic visibility score (DVS) used in the study?",{"text":117,"@type":113},"Visibility was graded with the DVS scale from 0 to 4, where 0 indicated excellent visibility and 4 indicated that the landmark was not visible due to artifacts.",{"name":119,"@type":110,"acceptedAnswer":120},"How did observers evaluate the CBCT images and handle scoring differences?",{"text":121,"@type":113},"Two trained evaluators independently reviewed the scans using standardized software while blinded to crown material. Any scoring discrepancies were resolved through mutual discussion and consensus.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},460205,1790758017,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":39,"preview_page_count":81,"preview_urls":143},962090769181,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Original Research  \nEvaluation of Diagnostic Visibility in CBCT Images with Prosthodontic Crown‑Induced Artifacts: Retrospective CBCT Analysis  \nAmalorpavam V1, VD Ponjayanthi2, Ramesh Raja S1, Giri Chandramohan3, Mary Sheloni Missier4, Allen Jim Hines3  \n1Department of prosthodontics, Rajas Dental College and Hospital, Tirunelveli, Tamil Nadu, India, 2Department of Prosthodontics, Vivekanadha Dental College for Women, Tiruchengode, Tamil Nadu, India, 3Department of Prosthodontics, Sree Mookambika Institute of Dental Sciences, Kulasekaram, Kanya Kumari, Tamil Nadu, India, 4Department of Orthodontics, Rajas Dental College and Hospital, Tirunelveli, Tamil Nadu, India  \nSubmitted: 23‑Jul‑2025  \nRevised: 03‑Aug‑2025  \nAccepted: 10‑Aug‑2025  \nPublished: 17‑Dec‑2025  \nAbstract  \nBackground: CBCT is widely used in dental diagnostics, but image artifacts from prosthodontic crowns can reduce diagnostic clarity. This study evaluated the effect of crown materials—metal, PFM, and zirconia—on CBCT visibility. Materials and Methods: CBCT scans of patients with different crowns were retrospectively analyzed. Key landmarks such as the periapical area, lamina dura, and bone were assessed using the diagnostic visibility score (DVS, 0–4) . Two observers independently evaluated the scans. Results: Metal crowns produced the most artifacts, followed by PFM crowns. Zirconia crowns caused minimal distortion, preserving visibility. Differences among groups were statistically significant with high interobserver agreement. Conclusion: Zirconia crowns provide better diagnostic visibility in CBCT scans. Crown material selection plays a vital role in image interpretation accuracy.  \nKeywords: CBCT, DVS, metal crowns, prosthodontic crowns, zirconia crowns   \nIntroduction  \none‑beam computed  \nCrevolutionized dental  \ntomography diagnostics  \n(CBCT) has by providing  \nhigh‑resolution, three‑dimensional imaging for the precise assessment of hard tissues.[1] It plays a pivotal role in implant planning, endodontic evaluation, and detecting periapical lesions.[1] However, one of its major limitations is the presence of artifacts—unwanted streaks or distortion often caused by metal objects within the scanned field.[2]  \n\n| Access this article online |  |\n| --- | --- |\n| Quick Response Code:\u003Cbr>| Website: [https://journals.lww.com/jpbs](https://journals.lww.com/jpbs) |\n|  | DOI: 10.4103/jpbs.jpbs_1281_25 |\n\nIn clinical practice, prosthodontic restorations like metal crowns, porcelain‑fused‑to‑metal (PFM) crowns, and  \nzirconia crowns are frequent sources of such artifacts.[2] These distortions may obscure vital anatomical details, complicating accurate diagnosis.[2]  \n\n| Address for correspondence: Dr. Amalorpavam V, Rajas Dental College and Hospital Tirunelveli, Tamil Nadu, India.\u003Cbr>E‑mail: [amalor.dr@gmail.com](amalor.dr@gmail.com) |\n| --- |\n| This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License (CC BY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.\u003Cbr>For reprints [contact:](contact: WKHLRPMedknow_reprints@wolterskluwer.com)[ WKHLRPMedknow_reprints@wolterskluwer.com](contact: WKHLRPMedknow_reprints@wolterskluwer.com) |\n| How to cite this article: Amalorpavam V, Ponjayanthi VD, Raja SR, Chandramohan G, Missier MS, Hines AJ. Evaluation of diagnostic visibility in CBCT images with prosthodontic crown‑induced artifacts: retrospective CBCT analysis. J Pharm Bioall Sci 2025;17:S3013‑5. |\n\n © 2025 Journal of Pharmacy and Bioallied Sciences | Published by Wolters Kluwer-Medknow S3013  \nWhile earlier studies have examined the artifact potential of various dental materials,[2] there is limited information on how these artifacts affect the visibility of key diagnostic landmarks.  \nThis study aims to fill that gap by retrospectively assessing the impac","cbCail14toIWJgR2","https://ap.wps.com/l/cbCail14toIWJgR2","pdf",983946,"English","# Introduction\n## Rationale and limitation of CBCT artifacts\n# Materials and Methodology\n## Study design and inclusion/exclusion criteria\n## CBCT acquisition and settings\n## Diagnostic Visibility Score (DVS)\n## Landmark assessment\n## Evaluator process and blinding\n# Statistical analysis\n## Mean DVS and interobserver agreement","[{\"question\":\"Which crown materials were compared for their effect on CBCT diagnostic visibility?\",\"answer\":\"The study compared metal crowns, porcelain-fused-to-metal (PFM) crowns, and zirconia crowns using archived CBCT scans.\"},{\"question\":\"What was the diagnostic visibility score (DVS) used in the study?\",\"answer\":\"Visibility was graded with the DVS scale from 0 to 4, where 0 indicated excellent visibility and 4 indicated that the landmark was not visible due to artifacts.\"},{\"question\":\"How did observers evaluate the CBCT images and handle scoring differences?\",\"answer\":\"Two trained evaluators independently reviewed the scans using standardized software while blinded to crown material. Any scoring discrepancies were resolved through mutual discussion and consensus.\"}]","Evaluation of Diagnostic Visibility in CBCT Images with Prosthodontic Crown-Induced Artifacts - Retrospective CBCT Analysis | PDF",[144,148,152],{"page_no":8,"url":145,"width":146,"height":147},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/dee8dfcad806fc4d7c2f09cd04432d16.webp",983,1272,{"page_no":14,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/149f1ae42785407419e8a61682674452.webp",982,1270,{"page_no":81,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/a2d518066ab8f9fe45d8f8aa84ead847.webp",981,1269]