[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-463380-105":59,"doc-detail-463380-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","evaluating-polymer-characterization-methods-to-establish-a-quantitative-method-of-compositional-analysis-using-a-polyvinyl-alcohol-pvapolyethylene-glycol-peg-based-hydrogel-for-biomedical-applications","Evaluating Polymer Characterization Methods to Establish a Quantitative Method of Compositional Analysis Using a Polyvinyl Alcohol (PVA)/Polyethylene Glycol (PEG)-Based Hydrogel for Biomedical Applications","","Multi-component polymer hydrogels exhibit complex physicochemical interactions that hinder accurate compositional analysis. This study assesses three techniques—NMR, Advanced Polymer Chromatography (APC), and Thermogravimetric Analysis (TGA)—to quantify polyvinyl alcohol (PVA) and polyethylene glycol (PEG) in hybrid freeze–thaw derived PVA/PEG/PVP hydrogels across a broad PVA:PEG ratio range. NMR and APC provide low average errors (2.77% and 2.01%) and remain robust against phase separation and hydrogen bonding effects, while TGA accuracy holds for PVA contents ≤62.5% and degrades at higher PVA due to hydrogen bonding and structural changes. FTIR observations link these effects to spectral shifts and altered-OH features, establishing APC as a high-throughput alternative and defining thermal/structural thresholds affecting TGA-based quantification.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/evaluating-polymer-characterization-methods-to-establish-a-quantitative-method-of-compositional-analysis-using-a-polyvinyl-alcohol-pvapolyethylene-glycol-peg-based-hydrogel-for-biomedical-applications/463380/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/evaluating-polymer-characterization-methods-to-establish-a-quantitative-method-of-compositional-analysis-using-a-polyvinyl-alcohol-pvapolyethylene-glycol-peg-based-hydrogel-for-biomedical-applications/463380.png","ImageObject",300,407,{"name":92,"@type":93},"Mafia Boss","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-25","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Which analytical methods are evaluated for quantifying PVA and PEG content in the hydrogels?","Question",{"text":112,"@type":113},"The study evaluates Nuclear Magnetic Resonance (NMR), Advanced Polymer Chromatography (APC), and Thermogravimetric Analysis (TGA) to quantify PVA and PEG in hybrid PVA/PEG/PVP hydrogels.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How do NMR and APC perform across the hydrogel compositions?",{"text":117,"@type":113},"NMR and APC reliably quantify polymer content with low average errors of 2.77% (NMR) and 2.01% (APC), and they are unaffected by phase separation or hydrogen bonding within the composite matrix.",{"name":119,"@type":110,"acceptedAnswer":120},"When does TGA provide accurate quantification, and what reduces its accuracy at higher PVA?",{"text":121,"@type":113},"TGA enables accurate quantification at PVA contents ≤62.5%, where PEG and PVA show distinct thermal decomposition behaviors. At higher PVA, increased hydrogen bonding and crystalline restructuring—supported by FTIR spectral shifts—alter thermal profiles and reduce TGA accuracy.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},463380,1791101796,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},962090760730,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Article  \nEvaluating Polymer Characterization Methods to Establish a Quantitative Method of Compositional Analysis Using a Polyvinyl Alcohol (PVA)/Polyethylene Glycol (PEG)—Based Hydrogel for Biomedical Applications  \nAntonio G. Abbondandolo , Anthony Lowman and Erik C. Brewer *  \nAcademic Editor: Hai-Feng (Frank) Ji  \nReceived: 8 December 2025  \nRevised: 18 December 2025  \nAccepted: 22 December 2025  \nPublished: 24 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \nDepartment of Biomedical Engineering, Rowan University, Glassboro, NJ 08028, USA  \n* [Correspondence: brewere@rowan.edu](Correspondence: brewere@rowan.edu); Tel.: +1-215-900-3027  \nAbstract  \nMulti-component polymer hydrogels present complex physiochemical interactions that make accurate compositional analysis challenging. This study evaluates three analytical techniques: Nuclear Magnetic Resonance (NMR), Advanced Polymer Chromatography (APC), and Thermogravimetric Analysis (TGA) to quantify polyvinyl alcohol (PVA) and polyethylene glycol (PEG) content in hybrid freeze-thaw derived PVA/PEG/PVP hydrogels. Hydrogels were synthesized using an adapted freeze–thaw method across a wide range of PVA:PEG ratios, with PVP included at 1 wt% to assess potential intermolecular effects. NMR and APC reliably quantified polymer content with low average errors of 2.77% and 2.01%, respectively, and were unaffected by phase separation or hydrogen bonding within the composite matrix. TGA enabled accurate quantification at PVA contents ≤ 62.5%, where PEG and PVA maintained distinct thermal decomposition behaviors. At higher PVA concentrations, increased hydrogen bonding and crystalline restructuring, confirmed by FTIR through shifts near 1140 cm−1 and significant changes in the-OH region, altered thermal profiles and reduced TGA accuracy. Together, these findings establish APC as a high-throughput alternative to NMR for multi-component polymer analysis and outline critical thermal and structural thresholds that influence TGA-based quantification. This work provides a framework for characterizing complex polymer networks in biomedical hydrogel systems.  \nKeywords: polyvinyl alcohol (PVA); polyethylene glycol (PEG); hydrogel; freeze-thaw  \n1. Introduction  \nVariations in intermolecular interactions within polymeric materials directly affect their resulting chemical and physical properties. Polyvinyl alcohol (PVA) is a synthetic polymer that is increasingly being used in biomedical applications due to its excellent biocompatibility, aqueous solubility, low toxicity, and tissue-mimicking properties [1] . In the biomedical space, it has been utilized in contact lenses [2], artificial pancreases [3], hemodialysis [4], tissue adhesion barriers [5], cartilage [6–8] and meniscus tissue replacements [9], wound dressings [10], degradable drug delivery systems [11], and as a nucleus pulposus replacement [12] . PVA can be manufactured with varying degrees of hydrolysis and molecular weight, resulting in an overall change on its chemical and physical properties and crystallinity behavior, allowing for fine-tuning of physiochemical properties  \ndepending on the desired application [1] . Whereas the properties of single polymer systems are generally well-understood, physiochemical insight into multi-component polymer networks is poorly defined.  \nThe properties of each individual polymer contribute to the overall physiochemical nature of the composite. Physical crosslinking is a more desirable, non-toxic method of hydrogel formulation that allows for the modification of physiochemical properties of PVA through hydrogen bonding with other polymers [1] . Thomas et al. [13] previously developed a polyvinyl alcohol (PVA)/polyvinylpyrrolidone (PVP) hydrogel for nucleus pulposus replacement and demonstrated that hydrogel swelling was stro","cbCaimiQxWWXWYYd","https://ap.wps.com/l/cbCaimiQxWWXWYYd","pdf",1731261,14,"English","# Introduction\n## Intermolecular interactions and property dependence in polymeric materials\n## Biomedical applications of PVA and tuning via hydrolysis and molecular weight\n## Hydrogel formulation via physical crosslinking and effects of PVA with other polymers\n## Phase-separated hybrid approaches using PEG to induce PVA phase separation\n## Challenges in analyzing multi-component, phase-separated polymer systems","[{\"question\":\"Which analytical methods are evaluated for quantifying PVA and PEG content in the hydrogels?\",\"answer\":\"The study evaluates Nuclear Magnetic Resonance (NMR), Advanced Polymer Chromatography (APC), and Thermogravimetric Analysis (TGA) to quantify PVA and PEG in hybrid PVA/PEG/PVP hydrogels.\"},{\"question\":\"How do NMR and APC perform across the hydrogel compositions?\",\"answer\":\"NMR and APC reliably quantify polymer content with low average errors of 2.77% (NMR) and 2.01% (APC), and they are unaffected by phase separation or hydrogen bonding within the composite matrix.\"},{\"question\":\"When does TGA provide accurate quantification, and what reduces its accuracy at higher PVA?\",\"answer\":\"TGA enables accurate quantification at PVA contents ≤62.5%, where PEG and PVA show distinct thermal decomposition behaviors. At higher PVA, increased hydrogen bonding and crystalline restructuring—supported by FTIR spectral shifts—alter thermal profiles and reduce TGA accuracy.\"}]","Evaluating Polymer Characterization Methods to Establish a Quantitative Method of Compositional Analysis Using a Polyvinyl Alcohol (PVA)/Polyethylene Glycol (PEG)-Based Hydrogel for Biomedical Applications | PDF",1790766492,35,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/11d74d45f118d2f4673061b51692b0a2.webp",983,1390,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/933bd40551593da563f2597501f59ac4.webp",982,1388,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/d9ffdabd74495eac78a5dd2af65fd2da.webp",981,1387,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/bcae5b65112dc737b8b976472ec5d773.webp",980,1385]