[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-641499-105":59,"doc-detail-641499-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","ev-inverter-series-operating-manual-revision-10400","EV Inverter Series - Operating Manual - Revision 1.04.00","","EV Inverter Series Operating Manual provides safety-focused installation, operation, and setup guidance for controlling 3Ø induction motors in the 0.25 to 3hp range and voltage classes 230 or 460VAC. It explains pre-connection review steps, receiving and inspection checks, and critical safety symbols and warnings, including waiting after power-off before touching components. The manual also covers keypad programming concepts, parameter groups F (Basic) and C (Advanced), optional MODBUS RTU communications, terminal descriptions, wiring diagrams, and troubleshooting through structured error-code tables.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ev-inverter-series-operating-manual-revision-10400/641499/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ev-inverter-series-operating-manual-revision-10400/641499.png","ImageObject",300,407,{"name":92,"@type":93},"Rainbow Cat","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-27","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What safety steps must be followed before wiring or touching components after power is turned off?","Question",{"text":112,"@type":113},"Wait at least 5 minutes after power is turned OFF until the charge indicator extinguishes completely before touching wiring, circuit boards, or components.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How should the inverter be checked when it is received?",{"text":117,"@type":113},"Verify the model and capacity on the nameplate match the purchase order, and inspect for transportation damage; do not apply power if damaged and contact a representative immediately.",{"name":119,"@type":110,"acceptedAnswer":120},"What parameter groups are used for programming control behavior?",{"text":121,"@type":113},"The manual uses two parameter sets: F (Basic) and C (Advanced), enabling flexible control for different application needs.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},641499,1792783056,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},962090769181,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","EV INVERTER SERIES  \nOperating Manual  \n110V 1Ø 0.2-1HP  \n0.2 – 0.75kW  \n230V 1Ø /3Ø 0.2-3HP  \n0.2 – 2.2kW  \n460V 3Ø 1-3HP  \n0.75 – 2.2kW  \nRevision: 1.04.00  \nTABLE OF CONTENTS  \nPage  \nIntroduction ……………………………………………………………………………….. 3  \nSection 1 Safety Precautions ………………………………………………………….. 3  \n1.1 Preface ………………………………………………………………….. 3  \n1.2 Receiving and Inspection ……………………………………………... 3  \n1.3 Installation and Pre-operation ………………………………………… 4  \n1.4 During Power ON ………………………………………………………. 4  \nFig. 1 EV Pictorial Wiring Diagram ……………………………………………… 5  \nSection 2 Inverter Option Modules…………………………………………………… 6  \nFig. 2.1 Option Card Installation and Wiring.................................. 6  \nFig. 2.2 RS485 Interface (P/N SIF-485) .......………………………. 7  \nFig. 2.3 RS232 Interface (P/N SIF-232)……………………………. 7  \nFig. 2.4 Copy Module (P/N SIF-MP)……………………………….. 7  \nFig. 2.5 Remote Keypad (P/N SDOP-LED-2M) ............................. 8  \nFig. 2.6 I/O Module (P/N SIF-IO)…………………………………….. 8  \nFig. 2.7 PDA Link………………………………………………………. 8  \nSection 3 Control Signal Terminal Block Description…………………………… 9  \nFig. 3.1 Control Terminals Designations…………………………… 9  \nSection 4 Input Power Terminal Block Description………………………………. 10  \nFig.4.1 Power Input Terminals Designations………………………… 10  \nSection 5 Output Power (Motor and Brake) Terminal Block Description…….. 10  \nFig. 5.1 Power Output Terminals Designations……………………. 10  \nSection 6 Peripheral Power Devices………………………………………………… 11  \nSection 7 Fuse Types and Ratings………………………………………………….. 12  \nSection 8 Quick Start Guide………………………………………………………….. 13  \nSection 9 Keypad Key Functions and Navigation………………………………… 14  \nFig. 9.1 EV Keypad  \n9.1 Key Functions………………………………………………………….…... 14  \n9.2 Keypad Navigation………………………………………………………… 15  \nFig. 9.2.1 Basic Keypad Control………………………………………. 15  \n9.3 Local / Remote Function………………………………………………….. 15  \n9.4 Setting Parameters F (Basic) and C (Advanced)………………………. 16  \nFig.9.4.1 Set F (Basic) and C (Advanced) Parameters……………… 16  \nSection 10 Parameters F (Basic) and C (Advanced)……………………………… 17  \nTable 10.1 F (Basic) Parameters……………………………………. 17-20  \nTable 10.2 C (Advanced) Parameters………………………………. 21-26  \nSection 11 Parameter Description (Basic) and C (Advanced)…………………. 27  \nBasic……………………………………………………………………… 27-42  \nAdvanced………………………………………………………………… 43-53  \nSection 12 Envelope and Dimensional Tables…………………………………...... 54  \nSection 13 Error Codes and Troubleshooting……………………………………….. 55  \nTable 13.1 Unresettable / Unrecoverable Errors…………….............. 55  \nTable 13.2 Automatically and Manually Recoverable Errors………… 56  \nTable 13.3 Manually Recoverable Only Errors (No Auto Restart)…… 57  \nTable 13.4 Set-up Configuration and Interface Errors……………….. 57-58  \nTable 13.5 Keypad Errors ……………………………………………..… 58  \nAppendix A Inverter Specifications.......................................................................... 59  \nInverter Basic Specifications................................................................. 59  \nInverter General Specifications............................................................. 60 – 62  \nAppendix B NEMA 4 Installation and Wiring............................................................ 63 – 66  \nAppendix C Inverter Parameter Setting List........................................................... 67  \nWarranty……………………………………………………………………………………… 68  \nIntroduction  \nThe EV Inverter series is state of the art design using the latest control and power technologies. It is designed to operate and control 3Ø induction motors in the range of 0.25 to 3hp and voltage class of 230 or 460VAC. The inverter can operate either in V/ for open loop vector mode settable via programming. There are two sets of parameters, F Basic, and C Advanced, allowing for flexible control in many different applications. The membrane keypad in combination with a 3 digit  \n7 segment display allow for ease of programming and monitoring.  \nAn optional communications module can be used for c","cbCaiom0PxEje5Kn","https://ap.wps.com/l/cbCaiom0PxEje5Kn","pdf",2152552,69,"English","# Introduction\n## Safety Precautions\n## Inverter Option Modules\n## Control Signal Terminal Block Description\n## Input Power Terminal Block Description\n## Output Power (Motor and Brake) Terminal Block Description\n## Peripheral Power Devices\n## Fuse Types and Ratings\n## Quick Start Guide\n## Keypad Key Functions and Navigation\n## Parameters F (Basic) and C (Advanced)\n## Parameter Description (Basic) and C (Advanced)\n## Envelope and Dimensional Tables\n## Error Codes and Troubleshooting\n## Appendix A Inverter Specifications\n## Appendix B NEMA 4 Installation and Wiring\n## Appendix C Inverter Parameter Setting List\n## Warranty","[{\"question\":\"What safety steps must be followed before wiring or touching components after power is turned off?\",\"answer\":\"Wait at least 5 minutes after power is turned OFF until the charge indicator extinguishes completely before touching wiring, circuit boards, or components.\"},{\"question\":\"How should the inverter be checked when it is received?\",\"answer\":\"Verify the model and capacity on the nameplate match the purchase order, and inspect for transportation damage; do not apply power if damaged and contact a representative immediately.\"},{\"question\":\"What parameter groups are used for programming control behavior?\",\"answer\":\"The manual uses two parameter sets: F (Basic) and C (Advanced), enabling flexible control for different application needs.\"}]","EV Inverter Series - Operating Manual - Revision 1.04.00 | PDF",1792714376,174]