[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-662743-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-662743-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","euh-series-technical-specifications-and-installation-information","EUH Series - Technical Specifications and Installation Information","","EUH series documents technical details for electric heating units, including color finish, heating element construction, insulation, and control features. It specifies heat output control options, installation components such as ceiling hanger brackets and optional wall brackets, and warranty coverage for complete units. A detailed product table lists catalog numbers with kW, BTU, voltage, phase, airflow (CFM), and unit weight, plus field-installed control options and accessories. Shipping, receiving, warehouse, and garage applications are also referenced.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/euh-series-technical-specifications-and-installation-information/662743/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/euh-series-technical-specifications-and-installation-information/662743.png","ImageObject",300,407,{"name":42,"@type":43},"WPS_1790064749","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What construction and finish features are specified for the EUH series units?","Question",{"text":62,"@type":63},"The document lists a hybrid polyester epoxy powder coat finish, die-formed steel housing, adjustable convex air-directing louvers, and a metal tubular sheath with spiral steel fins. It also specifies nickel chromium wire with magnesium oxide insulation.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"Which electrical parameters are provided in the EUH series specification table?",{"text":67,"@type":63},"For each catalog number, the table provides kW, BTU, volts, phase, CFM, and unit weight (kg/lbs). Some entries include combined ratings for different phases or voltage ranges.",{"name":69,"@type":60,"acceptedAnswer":70},"What field-installed control options and accessories are mentioned?",{"text":71,"@type":63},"The document mentions field installed summer fan control and low voltage control options, including a jumper to disable built-in thermostats when remote thermostats are required. It also lists a wall hanger bracket accessory for the EUH series (3–12kW).","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},662743,1793222213,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":33,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":123},3985747859154,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","EUH Series  \nColor Finish Voltage Construction  \nHeating Element  \nHeat Output  \nControl  \nInstallation  \nWarranty Applications  \nFeatures  \n- Almond  \n- Hybrid polyester epoxy powder coat paint finish  \n- 120,208,240,277,347,480,600;1 and 3 phase  \n- 18 gauge die formed steel  \n- Individual adjustable, single piece 20 gauge convex profile air directing louvers  \n- Metal tubular sheath fused with spiral steel fins  \n- High quality nickel chromium wire encased in solidly packed magnesium oxide insulation  \n- Fan size and pitch is matched to the power and speed of the unit to optimize CFM, airflow, temperature rise, and quietness  \n- Jumper provided to disable built-in thermostats when remote thermostats are required  \n- Field installed summer fan control and low voltage control options  \n- Ceiling hanger bracket included, optional wall bracket available (allows swivel movement)  \n- One-year warranty on complete unit  \n- Shipping/receiving areas, warehouse storage areas, garages  \nEUH Series  \nEUH Series  \nEUH  \n\n| Cat. No. | kW | BTU | Volts | Phase | CFM | Weight (kg/lbs.) | Qty |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| EUH02B21T | 2 | 6824 | 208 | 1 | 350 | 16 / 36 |  |\n| EUH02B24CT | 2 | 6824 | 208 | 1/3 | 350 | 16 / 36 |  |\n| EUH02B31T | 2 | 6824 | 240 | 1 | 350 | 16 / 36 |  |\n| EUH02B51CT | 2 | 6824 | 347 | 1 | 350 | 16 / 36 |  |\n| EUH02B71CT | 2 | 6824 | 480 | 1 | 350 | 16 / 36 |  |\n| EUH02B74CT | 2 | 6824 | 480 | 1/3 | 350 | 18 / 40 |  |\n| EUH02B81CT | 2 | 6824 | 600 | 1 | 350 | 18 / 40 |  |\n| EUH02B84CT | 2 | 6824 | 600 | 1/3 | 350 | 18 / 40 |  |\n| EUH03B11T | 3 | 10236 | 120 | 1 | 350 | 16 / 36 |  |\n| EUH03B24CT | 3 | 10236 | 208 | 1/3 | 350 | 16 / 36 |  |\n| EUH03B31T | 3 / 2.3 | 10236 | 240/208 | 1 | 350 | 16 / 36 |  |\n| EUH03B34CT | 3 / 2.3 | 10236 | 240/208 | 1/3 | 350 | 16 / 36 |  |\n| EUH03B41T | 3 | 10236 | 277 | 1 | 350 | 18 / 40 |  |\n| EUH03B51CT | 3 | 10236 | 347 | 1 | 350 | 18 / 40 |  |\n| EUH03B73CT | 3 | 10236 | 480 | 3 | 350 | 18 / 40 |  |\n| EUH03B81CT | 3 | 10236 | 600 | 1 | 350 | 18 / 40 |  |\n| EUH03B83CT | 3 | 10236 | 600 | 3 | 350 | 18 / 40 |  |\n| EUH04B24CT | 4 | 13648 | 208 | 1/3 | 350 | 16 / 36 |  |\n| EUH04B31T | 4 | 13648 | 240 | 1 | 350 | 16 / 36 |  |\n| EUH04B51CT | 4 | 13648 | 347 | 1 | 350 | 16 / 36 |  |\n| EUH04B71CT | 4 | 13648 | 480 | 1 | 350 | 18 / 40 |  |\n| EUH04B74CT | 4 | 13648 | 480 | 1/3 | 350 | 18 / 40 |  |\n| EUH04B81CT | 4 | 13648 | 600 | 1 | 350 | 18 / 40 |  |\n| EUH04B83CT | 4 | 13648 | 600 | 3 | 350 | 18 / 40 |  |\n| EUH05B24CT | 5 | 17060 | 208 | 1/3 | 350 | 16 / 36 |  |\n| EUH05B31T | 5/3.8 | 17060/12795 | 240/208 | 1 | 350 | 16 / 36 |  |\n| EUH05B34CT | 5/3.8 | 17060/12795 | 240/208 | 1/3 | 350 | 16 / 36 |  |\n| EUH05B41T | 5 | 17060 | 277 | 1 | 350 | 18 / 40 |  |\n| EUH05B51CT | 5 | 17060 | 347 | 1 | 350 | 18 / 40 |  |\n| EUH05B74CT | 5 | 17060 | 480 | 1/3 | 350 | 18 / 40 |  |\n| EUH05B84CT | 5 | 17060 | 600 | 1/3 | 350 | 18 / 40 |  |\n| EUH08B24CT | 7.5 | 25590 | 208 | 1/3 | 600 | 21 / 46 |  |\n| EUH08B34CT | 7.5/5.6 | 25590/19193 | 240/208 | 1/3 | 600 | 21 / 46 |  |\n| EUH08B74CT | 7.5 | 25590 | 480 | 1/3 | 600 | 22 / 50 |  |\n| EUH08B84CT | 7.5 | 25590 | 600 | 1/3 | 600 | 22 / 50 |  |\n| EUH10B24CT | 10 | 34120 | 208 | 1/3 | 600 | 21 / 46 |  |\n| EUH10B34CT | 10/7.5 | 34120/25590 | 240/208 | 1/3 | 600 | 21 / 46 |  |\n| EUH10B74CT | 10 | 34120 | 480 | 1/3 | 600 | 22 / 50 |  |\n| EUH10B84CT | 10 | 34120 | 600 | 1/3 | 600 | 22 / 50 |  |\n| EUH12B74CT | 12 | 40944 | 480 | 1/3 | 600 | 22 / 50 |  |\n| EUH12B84CT | 12 | 40944 | 600 | 1/3 | 600 | 22 / 50 |  |\n\nEUH Series  \nControl Options (field installed)  \n\n| Cat. No. | Description | Qty |\n| --- | --- | --- |\n| EUAF2 | Summer Fan Switch |  |\n\n\n| Cat. No. | Description | Qty |\n| --- | --- | --- |\n| EUHWB | Wall hanger bracket for EUH series (3-12kW) |  |\n\nAccessories (field installed)  \nSpecifications may change without prior notice  \n\n| Project: | Approval Information |\n| --- | --- |\n| Consultant Engineer: |  |\n| Electrician Contractor: | ","cbCaiiYw5UHlJ20Z","https://ap.wps.com/l/cbCaiiYw5UHlJ20Z","pdf",203599,"English","# EUH Series\n## Color Finish and Construction Features\n## Electrical and Performance Specifications\n## Control Options and Accessories\n## Approval Information","[{\"question\":\"What construction and finish features are specified for the EUH series units?\",\"answer\":\"The document lists a hybrid polyester epoxy powder coat finish, die-formed steel housing, adjustable convex air-directing louvers, and a metal tubular sheath with spiral steel fins. It also specifies nickel chromium wire with magnesium oxide insulation.\"},{\"question\":\"Which electrical parameters are provided in the EUH series specification table?\",\"answer\":\"For each catalog number, the table provides kW, BTU, volts, phase, CFM, and unit weight (kg/lbs). Some entries include combined ratings for different phases or voltage ranges.\"},{\"question\":\"What field-installed control options and accessories are mentioned?\",\"answer\":\"The document mentions field installed summer fan control and low voltage control options, including a jumper to disable built-in thermostats when remote thermostats are required. It also lists a wall hanger bracket accessory for the EUH series (3–12kW).\"}]","EUH Series - Technical Specifications and Installation Information | PDF"]