[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-674408-105":59,"doc-detail-674408-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","esrnpc-rd001-rev01-electrical-service-requirements-work-order-drawing-symbols","ESRNPC-RD001-REV01 - Electrical Service Requirements - Work Order Drawing Symbols","","Electrical Service Requirements RD-1 with work order drawing symbols. The document defines standard symbol sets and layout elements for electrical infrastructure, covering cabinets and associated notes/tags, overhead devices, poles and guys, risers, secondary equipment, transformers, underground boxes, and wire/cable classifications. It distinguishes existing versus proposed configurations and includes references for service drop, taps, conduits, and feeder/primary/secondary conductor options. Revision and page information are provided for controlled drawing usage.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/esrnpc-rd001-rev01-electrical-service-requirements-work-order-drawing-symbols/674408/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/esrnpc-rd001-rev01-electrical-service-requirements-work-order-drawing-symbols/674408.png","ImageObject",300,407,{"name":92,"@type":93},"Ophelia","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What is the scope of this RD-1 document?","Question",{"text":111,"@type":112},"It provides electrical service requirements using work order drawing symbols across multiple infrastructure components, including cabinets, overhead devices, poles and guys, risers, transformers, underground boxes, and wire/cable types.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"Does the document distinguish existing versus proposed installations?",{"text":116,"@type":112},"Yes. The symbol tables are organized under “EXISTING” and “PROPOSED” to show different configurations for the same component types.",{"name":118,"@type":109,"acceptedAnswer":119},"Which equipment categories are included for transformers and underground items?",{"text":120,"@type":112},"Transformer sections cover single-phase overhead and multiple three-phase pad-mount/inside-vault variants, while underground boxes include manholes, splice boxes, and pull boxes with 3-way/4-way underground modules and secondary J-box options.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},674408,1793762261,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":29,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":142},7971461741311,"https://ap-avatar.wpscdn.com/avatar/74000253aff267980c6?x-image-process=image/resize,m_fixed,w_180,h_180&k=1779345379180704826","Table of Contents  \n1. Cabinets .........................................................................................................................................................2  \n2. Notes and Tags .............................................................................................................................................2  \n3. Overhead Devices .........................................................................................................................................3  \n4. Poles and Guys .............................................................................................................................................3  \n5. Risers .............................................................................................................................................................3  \n6. Secondary Equipment ...................................................................................................................................4  \n7. Transformers .................................................................................................................................................4  \n8. Underground Boxes .......................................................................................................................................4  \n9. Wire and Cable ..............................................................................................................................................5  \n\n| |  |  |  | Electrical Service Requirements | \u003Cbr>RD-1 |\n| --- | --- | --- | --- | --- | --- |\n|  |  |  |  | Work Order Drawing Symbols |  |\n| Drawn: | Eng: | Appr: | Date: |  | Revision: 1 |\n| DH | MES | DA | 12/06 |  | Page 1 of 6 |\n\nSY MBOLS FOR WOR K OR DER MAP  \nEXISTING PROPOSED  \n1. CABINETS  \n| \u003Cbr>\u003Cbr>| M\u003Cbr>|\n| --- | --- |\n\n| | |\n| --- | --- |\n\n2. NOTES AND TAGS  \n3 Phase Service O/C  \nR R  \nA B  \nC  \nA  \nB  \nC  \nB  \nC  \nA  \nMeter Cabinet  \nFused Meter Cabinet Fuse Cabinet ( LF-4)  \nMeter S witch & Fuse Cabinet ( DF-9 or L F-9 ) Switch Cabinet ( DF-10 or L F-10 )  \nSwitch & Fuse Cabinet ( DF-11 or L F-11) Pad mount Capacitor Bank  \nOpen /Closed Delta Bank  \nRail Road Services  \nOverhead Phase Configuration  \nOverhead Phase Roll  \nConduit Stub with 3 M Marker Hex = Note No . Call Out  \nDriveway  \nStreet Light  \nFire Hydrant  \n|  | | M |\n| --- | --- | --- |\n\n| | |\n| --- | --- |\n\n3 Phase Service O/C  \nR R  \nABC  \nA B  \nB C  \nC  \nA  \nSY MBOLS FOR WOR K OR DER MAP  \nEXISTING PROPOSED  \n3. OVERHEAD DEVICES  \n\n| |\n| --- |\n| 6 0 0A \u003Cbr>|\n\n4. POLES AND GUYS  \nA i r B reak Sw itc h  \nRegulator  \nOverhead Capacitor Tap  \nBank  \n5.  \nRISERS  \nTrans m ission Pole  \nD ist ri but ion , Sole – Use Pole D ist ri but ion , Joi nt – Use Pole  \nS print , Sole – Use Pole  \nS print , Joint – Use Pole  \nDow n Guy  \nSidewalk Guy  \nSt rut G uy  \nSY MBOLS FOR WOR K OR DER MAP  \nEXISTING PROPOSED  \n6. SECONDARY EQUIPMENT  \n7.  \n ~~ ~~ ~~ ~~ Overhead Serv ice D rop  \n Overhead Secondary Tap  \n Underground Serv ice Left  \n Underground Serv ice Right  \n Underground Serv ice Tee  \nTRANSFORMERS  \nSingle Phase Overhead   \nThree Phase Pad mount Fused / Metered  \nThree Phase Pad mount Non-Fused  \nThree Phase Inside Vault Room  \n8. UNDERGROUND BOXES  \nManhole  \nSplice Box  \nPull Box w / 3-Way Underground Module  \nPull Box w / 4-Way Underground Module Secondary J-Box ( Hand hole )  \nSY MBOLS FOR WOR K OR DER MAP  \nEXISTING PROPOSED  \n9. WIRE AND CABLE  \n1  \nOverhead Primary Wire ( 954 AA ) ~~ ~~  \nOverhead Primary Wires ( all others ) ~~ ~~  \nOverhead Secondary Wire ~~ ~~  \nUnderground Feeder Cable ( 3-1000 kc mil ) ~~  ~~Underground Primary Cable ( 3-1/ 0 ) ~~ ~~  \nUnderground Primary Cable ( 1-1/ 0 , Phase A , B , or C ) ~~ ~~  1-1/ 0  ~~  ~~Underground Primary Cable 1 / 0 in Separate Conduit ~~ ~~ 1-1/ 0 4  C~~  ~~Underground Conduit ( Empty 4 \" = 4 C , 6 \" = 6 C ) ~~ ~~  \nUnderground Secondary Cable ~~ ~~ ~~ ~~ ~~ ~~  \n4 C  1      \nUnderground Secondary Cable in Separate Conduit  \nU","cbCaiuL5H1FF6qaR","https://ap.wps.com/l/cbCaiuL5H1FF6qaR","pdf",93811,"English","# Cabinets\n# Notes and Tags\n# Overhead Devices\n# Poles and Guys\n# Risers\n# Secondary Equipment\n# Transformers\n# Underground Boxes\n# Wire and Cable","[{\"question\":\"What is the scope of this RD-1 document?\",\"answer\":\"It provides electrical service requirements using work order drawing symbols across multiple infrastructure components, including cabinets, overhead devices, poles and guys, risers, transformers, underground boxes, and wire/cable types.\"},{\"question\":\"Does the document distinguish existing versus proposed installations?\",\"answer\":\"Yes. The symbol tables are organized under “EXISTING” and “PROPOSED” to show different configurations for the same component types.\"},{\"question\":\"Which equipment categories are included for transformers and underground items?\",\"answer\":\"Transformer sections cover single-phase overhead and multiple three-phase pad-mount/inside-vault variants, while underground boxes include manholes, splice boxes, and pull boxes with 3-way/4-way underground modules and secondary J-box options.\"}]","ESRNPC-RD001-REV01 - Electrical Service Requirements - Work Order Drawing Symbols | PDF",15]