[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-505274-105":59,"doc-detail-505274-en":135},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":128,"head_meta":130,"extra_data":132,"updated_unix":134},105,"en","epas-refrigerant-management-requirements-what-supermarkets-and-property-and-facility-managers-need-to-know","EPA’s Refrigerant Management Requirements - What Supermarkets and Property and Facility Managers Need to Know","","EPA Section 608 rules restrict the intentional release of refrigerant during maintenance, service, repair, or disposal of air-conditioning and refrigeration equipment. The fact sheet explains how supermarkets and property or facility managers must manage ozone-depleting refrigerants, focusing on recent leak repair updates. It details leak rate calculation triggers, repair timelines and thresholds, verification testing before and after additional refrigerant is added, inspection schedules, and retrofit or retirement plan obligations when leaks cannot be reduced.",{"@graph":69,"@context":127},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/epas-refrigerant-management-requirements-what-supermarkets-and-property-and-facility-managers-need-to-know/505274/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/epas-refrigerant-management-requirements-what-supermarkets-and-property-and-facility-managers-need-to-know/505274.png","ImageObject",300,407,{"name":92,"@type":93},"dawugda","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-21","2026-10-04",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",21,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119,123],{"name":110,"@type":111,"acceptedAnswer":112},"Which refrigerants and equipment are covered by Section 608 leak repair requirements?","Question",{"text":113,"@type":114},"Requirements apply to appliances containing 50 pounds or more of an ozone-depleting refrigerant used in industrial process refrigeration, commercial refrigeration, and comfort cooling. Appliances containing only certain substitute refrigerants such as HFCs are not covered under these leak repair provisions.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How and when must managers calculate refrigerant leak rates?",{"text":118,"@type":114},"Owners/operators must calculate the leak rate each time ozone-depleting refrigerant is added, unless the addition is made immediately after a retrofit, the installation of a new appliance, or it qualifies for a seasonal variance.",{"name":120,"@type":111,"acceptedAnswer":121},"What repair thresholds and verification testing steps are required?",{"text":122,"@type":114},"Managers must identify and repair leaks that exceed the applicable thresholds (30% for IPR, 20% for commercial refrigeration, and 10% for comfort cooling and other appliances) within 30 days of the refrigerant addition. They must document both an initial verification test before any additional refrigerant is added and a follow-up verification test after the system returns to normal operating characteristics.",{"name":124,"@type":111,"acceptedAnswer":125},"When are retrofit or retirement plans required?",{"text":126,"@type":114},"A retrofit or retirement plan must be created and implemented if owners/operators cannot bring the leak rate below the applicable threshold. The plan must be completed within one year of the plan’s date unless extra time is granted, and it must include required information about the appliance, refrigerants, conversion procedures (if retrofitting), recovered refrigerant disposition, appliance disposition (if retiring), and a completion schedule.","https://schema.org",{"og:url":83,"og:type":129,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":131,"canonical":83},"index,follow",{"doc_id":133,"site_id":62},505274,1791497615,{"code":4,"msg":5,"data":136},{"doc_id":133,"user_id":137,"nickname":92,"user_avatar":138,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":139,"file_id":140,"file_url":141,"file_type":142,"file_size":143,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":144,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":145,"faqs":146,"seo_title":147,"seo_description":67,"update_tm":148,"read_time":39,"preview_page_count":81,"preview_urls":149},3985747870947,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","EPA’s Refrigerant Management Requirements  \nWhat Supermarkets and Property and Facility  \nManagers Need to Know  \nWhat is Section 608?  \nSection 608 of the Clean Air Act prohibits the knowing release of refrigerant during the maintenance, service, repair, or disposal of air-conditioning (AC) and refrigeration equipment. EPA requires proper refrigerant management practices by those who buy or sell refrigerant, technicians, owners and operators of AC and refrigeration systems, and others. These requirements apply for all refrigerants that contain ozone-depleting substances, e.g. , hydrochlorofluorocarbons (HCFCs), and non-exempt substitute refrigerants, e.g. , hydrofluorocarbons (HFCs), hydrofluoroolefins (HFOs) and blends thereof.  \nSome refrigerants are exempt from the refrigerant management requirements. Examples include carbon dioxide, nitrogen, and water. Fora full list of exempt refrigerants, see 40 CFR § 82. 154(a) .  \nWhat are the Section 608 refrigerant management requirements for supermarkets and property and facility managers?1  \nThis fact sheet summarizes the leak repair requirements. These provisions recently changed as a result of EPA’s 2020 update.  \nThe leak repair regulations apply to industrial process refrigeration (IPR), commercial refrigeration, and comfort cooling and other appliances containing 50 pounds or more of an ozone-depleting refrigerant. These regulations do not apply to appliances containing solely substitute refrigerant such as HFCs.  \nLeak Rate Calculations  \nOwners/operators must calculate the leak rate every time ozone-depleting refrigerant is added to an appliance, unless the addition is made immediately following a retrofit, installation of a new appliance, or qualifies as a seasonal variance.  \nAppliance Repairs  \n• Owners/operators must identify and repair leaks that exceed 30% for IPR, 20% for commercial refrigeration, and 10% for comfort cooling and other appliances within 30 days of when the ozonedepleting refrigerant is added. Leaks must be repaired such that the leak rate is brought below the applicable leak rate.  \n• Owners/operators must perform and document both an initial and follow-up verification test of leak repairs for appliances that exceed the applicable leak rate.  \no An initial verification test must be performed before any additional refrigerant is added to the appliance.  \no A follow-up verification test must be performed only after the appliance has returned to normal operating characteristics and conditions. There is no minimum timeframe.  \n1 This fact sheet highlights select provisions that may be of most interest to this community. Please see the regulations at [https://go.usa.gov/xpKhq](https://go.usa.gov/xpKhq) for the full requirements.  \n• The verification tests must demonstrate that leaks were successfully repaired. If either the initial or follow-up verification test indicates that repairs were not successful, owners/operators may conduct as many additional repairs and verification tests as needed within the 30 day repair period.  \n• Owners/operators of IPR, commercial refrigeration, and comfort cooling equipment may request limited extensions to the 30 day repair deadline (120 days if an industrial process shutdown is required).  \n• If owners/operators fail to bring the leak rate below the threshold leak rate, owners/operators must create and implement a retrofit or retirement plan.  \nLeak Inspections  \n• Owners/operators must conduct leak inspections for appliances that have exceeded the applicable leak rate, according to the schedule in Table 1. Leak inspections must be conducted by a Section 608-certified technician. All visible and accessible components of an appliance must be inspected.  \nTable 1 : Leak Inspection Requirements  \n\n| Equipment | Full Charge | Frequency of Leak Inspections |\n| --- | --- | --- |\n| Commercial Refrigeration and Industrial Process Refrigeration | > 500 pounds | Once every three months until the owner/operator can demonstrate th","cbCaip1T1naPeEzT","https://ap.wps.com/l/cbCaip1T1naPeEzT","pdf",171313,"English","# What is Section 608?\n# Section 608 leak repair requirements for supermarkets and facility managers\n# Leak rate calculations\n# Appliance repairs and verification tests\n## Initial verification test\n## Follow-up verification test\n# Leak inspections\n# Retrofit or retirement plans","[{\"question\":\"Which refrigerants and equipment are covered by Section 608 leak repair requirements?\",\"answer\":\"Requirements apply to appliances containing 50 pounds or more of an ozone-depleting refrigerant used in industrial process refrigeration, commercial refrigeration, and comfort cooling. Appliances containing only certain substitute refrigerants such as HFCs are not covered under these leak repair provisions.\"},{\"question\":\"How and when must managers calculate refrigerant leak rates?\",\"answer\":\"Owners/operators must calculate the leak rate each time ozone-depleting refrigerant is added, unless the addition is made immediately after a retrofit, the installation of a new appliance, or it qualifies for a seasonal variance.\"},{\"question\":\"What repair thresholds and verification testing steps are required?\",\"answer\":\"Managers must identify and repair leaks that exceed the applicable thresholds (30% for IPR, 20% for commercial refrigeration, and 10% for comfort cooling and other appliances) within 30 days of the refrigerant addition. They must document both an initial verification test before any additional refrigerant is added and a follow-up verification test after the system returns to normal operating characteristics.\"},{\"question\":\"When are retrofit or retirement plans required?\",\"answer\":\"A retrofit or retirement plan must be created and implemented if owners/operators cannot bring the leak rate below the applicable threshold. The plan must be completed within one year of the plan’s date unless extra time is granted, and it must include required information about the appliance, refrigerants, conversion procedures (if retrofitting), recovered refrigerant disposition, appliance disposition (if retiring), and a completion schedule.\"}]","EPA’s Refrigerant Management Requirements - What Supermarkets and Property and Facility Managers Need to Know | PDF",1791094393,[150,154,158],{"page_no":8,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/0edd2d8389d059c762e3f9592b45a401.webp",983,1272,{"page_no":14,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/2f6e153ea97c57e295b869dc67969873.webp",982,1270,{"page_no":81,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ba63239ac1a6c5462f3da0867412036c.webp",981,1269]