[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-505442-105":59,"doc-detail-505442-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","epa-post-storm-guidance-refrigerant-containing-materials-updated-september-2018","EPA Post-Storm Guidance - Refrigerant-Containing Materials - Updated September 2018","","Guidance explains safe handling and disposal of refrigerant-containing appliances and vehicles after natural disasters, emphasizing federal environmental law. It states that knowingly venting or releasing refrigerants during disposal or preparation is illegal, covering vehicles and small appliances such as refrigerators, freezers, air conditioners, and dehumidifiers. The guidance requires using EPA-certified recovery and/or recycling equipment and certified technicians, describes procedures to identify refrigerant types, evacuate to 0 psig, prevent mixing, and document proper recovery before shipment to an EPA-certified reclaimer.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/epa-post-storm-guidance-refrigerant-containing-materials-updated-september-2018/505442/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/epa-post-storm-guidance-refrigerant-containing-materials-updated-september-2018/505442.png","ImageObject",300,407,{"name":92,"@type":93},"Ivy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04","2026-10-04",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",13,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What is prohibited when disposing of refrigerant-containing equipment after natural disasters?","Question",{"text":113,"@type":114},"It is illegal to knowingly vent or release refrigerants when disposing (or preparing to dispose) of a vehicle, small appliance, residential air conditioner, refrigerated trailer, or other refrigerant-containing equipment.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What equipment and labels are required for refrigerant recovery and recycling?",{"text":118,"@type":114},"You must use EPA-certified refrigerant recovery and/or recycling equipment. Certified units carry a label from ETL, AHRI, or UL indicating which refrigerant types the unit can recover.",{"name":120,"@type":111,"acceptedAnswer":121},"How should refrigerant be recovered from MVACs and small appliances?",{"text":122,"@type":114},"Determine refrigerant type and charge amount, use certified equipment to evacuate to 0 psig, recover into a container used only for that refrigerant type, and store by refrigerant type (or use a mixed refrigerant container if unknown or contaminated). A signed statement must be provided to recyclers or landfill operators confirming proper recovery.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},505442,1791160613,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":39,"preview_page_count":81,"preview_urls":145},549758252649,"https://ap-avatar.wpscdn.com/avatar/8000253669c5317157?_k=1778319167496531819","GUIDANCE FOR SAFE HANDLING OF  \nREFRIGERANT-CONTAINING APPLIANCES/VEHICLES  \nAFTER NATURAL DISASTERS  \nUpdated September 2018  \nFederal environmental laws govern the handling and disposal of equipment containing refrigerants. This information is provided to help minimize the health, safety, and environmental risks associated with handling and disposing of air-conditioning and refrigeration appliances under the extraordinary circumstances following natural disasters.  \nIt is illegal to knowingly vent or release refrigerants when disposing (or preparing to dispose) of a vehicle, small appliance (e.g., refrigerators, freezers, window air conditioners, or dehumidifiers), residential air conditioner, refrigerated trailer, or other refrigerant-containing equipment.  \nChlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs) are ozone-depleting substances that are commonly used as refrigerants. Today, motor vehicles, small appliances, and residential air conditioners use substitute refrigerants, such as hydrofluorocarbons (HFCs), hydrofluoroolefins (HFOs), and hydrocarbons, which do not deplete the ozone layer, but have other environmental impacts. Federal requirements apply to the handling and disposal of equipment containing CFCs, HCFCs, and substitute refrigerants. These requirements are intended to reduce emissions of ozone-depleting and other harmful substances during appliance disposal. Once it is safe to access appliances, adequate measures must betaken during emergency situations to minimize release of and exposure to such materials during equipment handling and disposal.  \nYou must use EPA-certified refrigerant recovery and/or recycling equipment. EPA-certified equipment will have a label from Environmental Testing Laboratories (ETL), the Air Conditioning, Heating, and Refrigeration Institute (AHRI) or Underwriters Laboratories (UL) stating which types of refrigerants the unit is capable of recovering.  \nPersons maintaining, servicing, or repairing equipment containing refrigerants are required to have a certification from an EPA-approved technician certification program. However, persons recovering refrigerant from small appliances (e.g., refrigerators, freezers, window air conditioners, or dehumidifiers) or motor vehicle air conditioners (MVACs) are not required to be EPA-certified if the refrigerant is being removed for the purpose of disposal of the vehicle or small appliance and the refrigerant will be sent for disposal or to an EPA-certified reclaimer.  \nThe following webpages have information on disposal of appliances:  \n• [MVACs:](MVACs: www.epa.gov/mvac)[ ](MVACs: www.epa.gov/mvac)[www.epa.gov/mvac](MVACs: www.epa.gov/mvac)  \n• Disposal of Small Appliances [and MVACs:](and MVACs: www.epa.gov/section608/stationary-refrigeration)[ ](and MVACs: www.epa.gov/section608/stationary-refrigeration)[www.epa.gov/section608/stationary-refrigeration](and MVACs: www.epa.gov/section608/stationary-refrigeration)safe-disposal-requirements  \n• Frequent Questions on Disposal of Small Appliances and MVACs:  \n[www.epa.gov/section608/frequently-asked-questions-about-safe-disposal-refrigerated](www.epa.gov/section608/frequently-asked-questions-about-safe-disposal-refrigerated)household-appliances  \nMore information on the requirements for some types of equipment is included in this document below. Additional requirements exist for larger appliances, such as chillers, industrial process refrigeration and other stationary air-conditioning and refrigeration equipment. For more information, visit [www.epa.gov/section608](www.epa.gov/section608) .  \nRecovery of Refrigerants from Motor Vehicle Air Conditioners and Small Appliances  \nMotor Vehicle Air Conditioners: An MVAC is the refrigeration equipment used to cool the  \ndriver/passenger compartment of any motor vehicle, including passenger cars, light duty vehicles, and heavy duty vehicles.  \nSmall Appliances: These appliances, sometimes called “white goods”, include refrigerators, freez","cbCailuCqskR9Kqe","https://ap.wps.com/l/cbCailuCqskR9Kqe","pdf",157208,"English","# Guidance for Safe Handling of Refrigerant-Containing Appliances/Vehicles After Natural Disasters\n## Legal Requirements and Environmental Risk Reduction\n## EPA-Certified Recovery and Technician Certification\n## Recovery Requirements for MVACs and Small Appliances\n## Recovery of Refrigerants from Refrigerated Trailers and Residential Equipment","[{\"question\":\"What is prohibited when disposing of refrigerant-containing equipment after natural disasters?\",\"answer\":\"It is illegal to knowingly vent or release refrigerants when disposing (or preparing to dispose) of a vehicle, small appliance, residential air conditioner, refrigerated trailer, or other refrigerant-containing equipment.\"},{\"question\":\"What equipment and labels are required for refrigerant recovery and recycling?\",\"answer\":\"You must use EPA-certified refrigerant recovery and/or recycling equipment. Certified units carry a label from ETL, AHRI, or UL indicating which refrigerant types the unit can recover.\"},{\"question\":\"How should refrigerant be recovered from MVACs and small appliances?\",\"answer\":\"Determine refrigerant type and charge amount, use certified equipment to evacuate to 0 psig, recover into a container used only for that refrigerant type, and store by refrigerant type (or use a mixed refrigerant container if unknown or contaminated). A signed statement must be provided to recyclers or landfill operators confirming proper recovery.\"}]","EPA Post-Storm Guidance - Refrigerant-Containing Materials - Updated September 2018 | PDF",1791148374,[146,150,154],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/5222916b183e291f9f47cb8e0610929d.webp",983,1272,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/d1f1ab0d2486ef64b2178d1ea6f77d24.webp",982,1270,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/817974743e02c2aa6c041300ae16e7ab.webp",981,1269]