[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-673519-105":59,"doc-detail-673519-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","enervista-integrator-quickstart-guide","EnerVista Integrator Quickstart Guide","","EnerVista Integrator Quickstart Guide describes GE Multilin EnerVista Integrator, a power management control system that unifies POWER LEADER devices and Modbus RTU and Ethernet TCP/IP connectivity. The guide outlines key performance characteristics such as near real-time screen refresh, event and alarm access, baud-rate and response-time targets, and envelope limits for IEDs, I/O points, and OPC tag capacity. It also summarizes supported features, security options, and the main server executables and their roles in polling Modbus data, events, and waveforms, plus associated viewers.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/enervista-integrator-quickstart-guide/673519/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/enervista-integrator-quickstart-guide/673519.png","ImageObject",300,407,{"name":92,"@type":93},"Genevieve","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04","2026-11-02",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What network protocols and operating environment does EnerVista Integrator support?","Question",{"text":112,"@type":113},"EnerVista Integrator supports Modbus RTU and Ethernet TCP/IP networking and is optimized for the Windows operating system, with built-in Ethernet compatibility.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the performance and responsiveness targets mentioned in the guide?",{"text":117,"@type":113},"The guide lists near real-time refresh via critical event/alarm access, up to 38.4 kbps on Modbus RTU and 10 Mbps on Ethernet TCP/IP, with a 1 second response time for device setting/command coil changes and burst support for device events per second.",{"name":119,"@type":110,"acceptedAnswer":120},"Which server executables and viewers are included in the EnerVista Integrator suite?",{"text":121,"@type":113},"The suite includes Modbus servers such as GE32MODB.exe and GE32MTCP.exe, an Eventserver.exe with Eventlog.exe for events, a Wfserver.exe with WFC.exe and WaveformViewer.exe for waveform retrieval and viewing.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},673519,1793647487,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":26},1374391974585,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","GE  \nDigital Energy  \nEnerVista Integrator Quickstart Guide  \nGE publication code: 1601-9213-A1 (GEK-119527)  \n[GEDigitalEnergy.com](GEDigitalEnergy.com)  \nCopyright © 2013 GE Multilin Inc. All rights reserved.  \nEnerVista Integrator software revision 7. 0x.  \nEnerVista, Integrator, POWER LEADER, Digital Energy, Multilin, and GE Multilin are trademarks or registered trademarks of GE Multilin Inc.  \nThe contents of this manual are the property of GE Multilin Inc. This documentation is furnished on license and may not be reproduced in whole or in part without the permission of GE Multilin. The manual is for informational use only and is subject to change without notice.  \nPart number: 1601-9213-A1 (March 2013)  \nEnerVista Integrator Quickstart Guide  \nIntroduction  \nEnerVistaTM IntegratorTM is the latest Power Management Control System in the EnerVista line from GE Multilin. EnerVista Integrator integrates the comprehensive line of POWER LEADER devices, as well as many new Modbus RTU devices and systems. EnerVista Integrator comes with built-in Ethernet compatibility and is optimized for the Windows operating system. In addition, the software can be installed and used with administrative user login. All of this adds up to the most flexible, high-performance, open-architecture power-management system available. EnerVista Integrator software is the heart of your new power management system, with state-of-the-art graphics and features designed to maximize productivity and minimize downtime and energy costs.  \nPerformance  \nEnerVista Integrator delivers critical power-management information at baud rates up to 38.4 kbps on a Modbus RTU network and 10 Mbps on  \nENERVISTA INTEGRATOR QUICKSTART GUIDE 1  \nQUICKSTART GUIDE  \nan Ethernet TCP/IP network. This results in near real-time screen refresh rates and immediate access to critical event and alarm data.  \nFeatures  \nEnerVista Integrator comes with the following features that make the system powerful and easy to use:  \n• Compatible with industry-standard third-party SCADA platforms  \n• Built-in Modbus RTU network compatibility for an open network architecture and high-speed communication  \n• Built-in Ethernet TCP/IP network compatibility for high-speed communication and reduced wiring costs  \n• Built-in support for POWER LEADER and Multilin powermanagement devices, as well as additional GE meters and relays, Fanuc 90/30 and 90/70 programmable logic controllers, and thirdparty meters and relays  \n• 3D virtual-device interaction with accurately reproduced device look and feel  \n• Improved waveform capture, including extensive analysis tools  \n• Comprehensive alarm and event reporting for immediate diagnosis of electrical system problems  \n• Single Viewer Workstation support for seamless access and sharing of power-management data across your existing local area network (LAN)  \n• Configurable password protection and user-activity logging for improved security and restriction of setup or control operations  \n• Optional EnerVista Integrator modules are available to further increase productivity and reduce energy costs  \nEnerVista Integrator envelope definition  \n1. Physical system size  \n• 75 power management devices (intelligent electronic devices, or IEDs) (300 maximum)  \n2 ENERVISTA INTEGRATOR QUICKSTART GUIDE  \nQUICKSTART GUIDE  \n• 150 I/O points (through IEDs or programmable logic controllers, or PLCs)  \n• 64 Ethernet serial communications ports  \n• 2 Modbus monitors (maximum) using standard Modbus Monitor Proxy  \n2. OPC clients data items size  \n• Up to 30,000 points/tags in OPC clients  \n• 10% of tags connected to enterprise solution  \n3. Special application issues  \n• No redundancy  \n4. Performance  \nResponse times:  \n• 1 second response time to make device change (settings/ command coil) not including device feedback  \n• 1000 device events/sec burst support Configuration:  \n• Maximum 15 devices per serial port  \n• Device baud rates set to maximum  \n• Devices supporting 125 registe","cbCais8HIoW5NlhO","https://ap.wps.com/l/cbCais8HIoW5NlhO","pdf",752284,24,"English","# Introduction\n# Performance\n# Features\n# EnerVista Integrator Envelope Definition\n# Servers and Executables\n# Devices Supported","[{\"question\":\"What network protocols and operating environment does EnerVista Integrator support?\",\"answer\":\"EnerVista Integrator supports Modbus RTU and Ethernet TCP/IP networking and is optimized for the Windows operating system, with built-in Ethernet compatibility.\"},{\"question\":\"What are the performance and responsiveness targets mentioned in the guide?\",\"answer\":\"The guide lists near real-time refresh via critical event/alarm access, up to 38.4 kbps on Modbus RTU and 10 Mbps on Ethernet TCP/IP, with a 1 second response time for device setting/command coil changes and burst support for device events per second.\"},{\"question\":\"Which server executables and viewers are included in the EnerVista Integrator suite?\",\"answer\":\"The suite includes Modbus servers such as GE32MODB.exe and GE32MTCP.exe, an Eventserver.exe with Eventlog.exe for events, a Wfserver.exe with WFC.exe and WaveformViewer.exe for waveform retrieval and viewing.\"}]","EnerVista Integrator Quickstart Guide | PDF"]