[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-653247-105":59,"doc-detail-653247-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","emtx-svx01m-en-installation-operation-and-programming-rover-service-tool","EMTX-SVX01M-EN - Installation, Operation, and Programming - Rover Service Tool","","Installation, operation, and programming guidance for the Rover™ Service Tool is provided for qualified personnel. The manual explains installation and starting procedures for HVAC-related equipment, including safety warnings, cautions, and notices covering electrical, mechanical, and chemical hazards. It defines advisory types and highlights requirements for proper field wiring and grounding. It also introduces Rover software usage and user interface screens, including device connections, dialog boxes, and verification of network communications via various adapters.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/emtx-svx01m-en-installation-operation-and-programming-rover-service-tool/653247/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/emtx-svx01m-en-installation-operation-and-programming-rover-service-tool/653247.png","ImageObject",300,407,{"name":92,"@type":93},"Mary Man","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-31","2026-10-25",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is allowed to install and service the Rover Service Tool equipment?","Question",{"text":112,"@type":113},"Only qualified personnel should install and service the equipment. Improper installation, adjustment, or alteration by unqualified persons can cause death or serious injury.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What PPE is required before installing or servicing the unit?",{"text":117,"@type":113},"Technicians must put on all required PPE for the work being undertaken, including appropriate electrical PPE and arc flash clothing when risk of energized electrical contact exists. Always follow MSDS/SDS and OSHA guidelines.",{"name":119,"@type":110,"acceptedAnswer":120},"What field wiring and grounding requirements are emphasized?",{"text":121,"@type":113},"Proper field wiring and grounding are required. All field wiring must be performed by qualified personnel and must follow NEC and local/state electrical codes to avoid fire and electrocution hazards.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},653247,1793090003,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},7421720224475,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Installation, Operation, and Programming  \nRover™ Service Tool  \n| SAFETY WARNING |\n| --- |\n| Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. |\n\nMarch  \n2020  \nEMTX-SVX01M-EN  \nIntroduction  \nThis document covers installation, connection techniques used for various devices, describes the Rover user interface screens and dialog boxes, and explains how to use the software features.  \nWarnings, Cautions, and Notices  \nSafety advisories appear throughout this manual as required. Your personal safety and the proper operation of this machine depend upon the strict observance of these precautions.  \nThe three types of advisories are defined as follows:  \n\n| WARNING |\n| --- |\n|  |\n| CAUTIONs |\n|  |\n| NOTICE |\n\nIndicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.  \nIndicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It could also be used to alert against unsafe practices. Indicates a situation that could result in equipment or property-damage only accidents.  \n\n| WARNING |\n| --- |\n| Proper Field Wiring and Grounding Required!\u003Cbr>Failure to follow code could result in death or serious injury. All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state electrical codes. Failure to follow code could result in death or serious injury. |\n\n\n| WARNING |\n| --- |\n| Personal Protective Equipment (PPE) Required!\u003Cbr>Installing/servicing this unit could result in exposure to electrical, mechanical and chemical hazards.\u003Cbr>• Before installing/servicing this unit, technicians MUST put on all PPE required for the work being undertaken (Examples; cut resistant gloves/sleeves, butyl gloves, safety glasses, hard hat/bump cap, fall protection, electrical PPE and arc flash clothing) . ALWAYS refer to appropriate Material Safety Data Sheets (MSDS)/Safety Data Sheets (SDS) and OSHA guidelines for proper PPE.\u003Cbr>• When working with or around hazardous chemicals, ALWAYS refer to the appropriate MSDS/ SDS and OSHA/GHS (Global Harmonized System of Classification and Labelling of Chemicals) guidelines for information on allowable personal exposure levels, proper respiratory protection and handling instructions.\u003Cbr>• If there is a risk of energized electrical contact, arc, or flash, technicians MUST put on all PPEin accordance with OSHA, NFPA 70E, or other country-specific requirements for arc flash protection, PRIOR to servicing the unit. NEVER PERFORM ANY SWITCHING, DISCONNECTING, OR VOLTAGE TESTING WITHOUT PROPER ELECTRICAL PPE AND ARC FLASH CLOTHING. ENSURE ELECTRICAL METERS AND EQUIPMENT ARE PROPERLY RATED FOR INTENDED VOLTAGE.\u003Cbr>Failure to follow instructions could result in death or serious injury. |\n\n© 2020 Trane EMTX-SVX01M-EN  \nIntroduction  \nCopyright  \nThis document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission. Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change.  \nTrademarks  \nAll trademarks referenced in this document are the trademarks oftheir respective owners.  \nRevision History  \n• Updated for new branding  \nEMTX-SVX01M-EN 3  \nTable of Contents  \nTable of Contents ..............","cbCairW1cVKXvw9t","https://ap.wps.com/l/cbCairW1cVKXvw9t","pdf",2340304,68,"English","# Introduction\n## Safety Warnings and Advisories\n## Warnings, Cautions, and Notices\n# Rover Installation\n## Laptop Requirements\n## Rover Components\n## About Rover\n## Devices and Plug-ins\n## Rover Comm4\n## Rover LonTalk\n## Other Tools\n## Connecting to LonTalk Links\n## Connecting a Communication Key\n## Connecting Rover to a Device\n## Connecting to a Zone Sensor\n## Connecting Using Alligator Clips\n## Alternate Wiring\n## Verifying Network Communications\n# Copyright and Revision History","[{\"question\":\"Who is allowed to install and service the Rover Service Tool equipment?\",\"answer\":\"Only qualified personnel should install and service the equipment. Improper installation, adjustment, or alteration by unqualified persons can cause death or serious injury.\"},{\"question\":\"What PPE is required before installing or servicing the unit?\",\"answer\":\"Technicians must put on all required PPE for the work being undertaken, including appropriate electrical PPE and arc flash clothing when risk of energized electrical contact exists. Always follow MSDS/SDS and OSHA guidelines.\"},{\"question\":\"What field wiring and grounding requirements are emphasized?\",\"answer\":\"Proper field wiring and grounding are required. All field wiring must be performed by qualified personnel and must follow NEC and local/state electrical codes to avoid fire and electrocution hazards.\"}]","EMTX-SVX01M-EN - Installation, Operation, and Programming - Rover Service Tool | PDF",1792887308,171]