[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-detail-227624-en":3,"doc-seo-227624-105":31,"detail-sidebar-cat-0-en-105":91},{"code":4,"msg":5,"data":6},0,"success",{"doc_id":7,"user_id":8,"nickname":9,"user_avatar":10,"doc_module":4,"category_id":11,"category_name":12,"doc_title":13,"doc_description":14,"doc_content":15,"file_id":16,"file_url":17,"file_type":18,"file_size":19,"view_count":20,"is_deleted":4,"is_public":21,"is_downloadable":21,"audit_status":21,"page_count":22,"language":23,"language_code":24,"site_id":25,"html_lang":24,"table_of_contents":26,"faqs":27,"seo_title":28,"seo_description":14,"update_tm":29,"read_time":30},227624,962084925782,"Chloe Bennett","https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc",6,"Technology","Electro-Optical Absolute Encoders with PROFIBUS-DP-Interface - KBD 58 and KRD 58 series - Issue 01 / 2005","Electro-Optical Absolute Encoders with PROFIBUS-DP interface from the KBD 58 and KRD 58 series provide singleturn (360°) and multiturn (4096 revolutions) absolute position measurement with 12 to 16 bit resolutions. The device supports PROFIBUS-DP slave station operation via an SPC3 Siemens controller, with selectable configuration for Class 1/2 diagnostics and optional functions. Two physical variants are offered (L with round connector, Z with connecting cap) including addressing, termination handling, LED diagnostics, and preset control. Electrical and mechanical specifications cover RS-485 line driving, supply voltage range, power consumption, max speed, and EMC standards.","| | Electro-Optical Absolute Encoders\u003Cbr>with PROFIBUS-DP-Interface\u003Cbr>KBD 58 and KRD 58 series | KRD 10941 FE |\n| --- | --- | --- |\n|  |  | 01 / 2005 |\n\n! Series KBD 58: Singleturn Measuring range 360°   \n! Series KRD 58: Multiturn Measuring range 4096 revolutions  \n! Resolutions: 12 to 16 Bits / 360°\u003C)(4096 to 65.536 positions / 360°\u003C) )  \n! Total capacity: 228 (28 Bits)  \n! Transmission rate: 12 MBaud max.  \n! Option: Preset function  \n! Model 58-S with synchro flange Model 58-K with clamping flange  \n! Variant \"L\" with round connector Variant \"Z\" with connecting cap  \n! Protection grades: IP 65 or IP 66  \n\n| | | \u003Cbr>Model 58 Variant \" | -S\u003Cbr>Z\" |\n| --- | --- | --- | --- |\n\nConstruction  \nFlange and housing of aluminium - shaft of stainless steel- 12 mm ball-bearings with Nilos ring seal or radial packing ring seal-code disk of deformation resistant plastic-GaAlAs diodes - photo-transistor array with comparator and trigger circuits for long-term stabilization of the sensor systems gate array-SMD technology.  \nGeneral features and modes of connection  \nThe CRD encoders are designed for connecting directly to PROFIBUS-DP buses as slave stations. The interface is realized with the SPC3 Siemens PROFIBUS controller. The protocol is executed in accordance with DP-slave class 2 functionality as laid down in Profibus-Profile for Encoders, No.  \n3.062 and is described in detail in the user manual KRD 11109. Compared to the CRD series KBD and KRD items provide additional optional functions, i.e. a 32-Bits velocity signal and short dignostic functionality.  \n(For detailes [ref. to](ref. to) table page 4) .  \nBlock diagram  \nMult i-functional ASIC µControl ler-System  \nPROFIBUS Controller  \nVariant L with RS 25 round connector:  \n\" The encoder is connected tothebuswitha cable (connector arrangement in accordance with profile description for encoders) .  \n\" The default address is changed via the service for changing the station address of a DP slave, namely DDLM_Set_Slave_Add. The bus-termination resistors have to be installed externally.  \n\" For stub connection refer to PROFIBUS-DP / FMS instruction (PNO-order no. 2. 111)  \nVariant Z with connecting cap  \n(T-coupler functionality with integrated addressing)  \nThis variant is designed for the following connection cablesand provides the following functions:  \n\" DIP- switches to set the station address and the termination resistances  \n\" Diagnosis LED's showing ON, SRD, Class and Error  \n\" Preset touch button  \n\" 1 cable for the supply voltage  \n(+ VS = 24 VDC, -VS = 0 VDC), PG 7 cable gland  \n\" 1 cable for Bus In ( A, B ), PG 9 cable gland  \n\" 1 cable for Bus Out (A', B'), PG 9 cable gland  \n\" The station address and bus-termination resistors are set with DIP switches in the connecting cap.  \nTWK-ELEKTRONIK GmbH · PB. 10 50 63 · D-40041 Düsseldorf · Tel.: +49/211/63 20 67 · Fax: +49/211/63 77 05 · [info@twk.de](info@twk.de) · [www.twk.de](www.twk.de)  \n Electro-Optical Absolute Encoders KBD / KRD 58-S/K  \nElectrical data  \n! Sensor system: GaAlAs diodes, photo-transistor array  \n! Resolution: 65536 positions / 360° max.  \n! Measuring range: 4096 revolutions  \n! Total number of KBD: 216 (16 Bits) positions: KRD: 228 (16 + 12 Bits)  \n! Output code: Natural binary  \n! Max. position variance: ≤ 2' 38\" at 4096 positions/360°  \n≤ ±1'59 at 8192 positions/360°  \n! Code sense: CW or CCW; (programmable)  \n! Supply voltage range: + 13,5 VDC to + 30 VDC  \n! Power consumption: PD ≤ 3,5 W  \n(Inrush current ≤ 300 mA)  \n! Interface: Line driver in acc. with RS 485; galvanic separation is achieved with an opto-coupler (data lines A, B) . Supply voltage galvanic separation is achieved with DC/ DC-converter  \n! Electromagnetic  \ncompatibility (EMC): EN 50081-2, EN 50082-2  \nMechanical data  \n! Operating speed: 6000 rpm max.  \n! Angular acceleration: 105 rad/s² max.  \n! Moment of inertia (rotor): 45 gcm²  \n! Operating torque: ≤ 5 Ncm (8 Ncm-KBD-K, KRD-K)(at 1000 rpm)  \n! Starting torque: ≤ 1 Ncm (4 Ncm-KBD","cbCaicatmNlAykNl","https://ap.wps.com/l/cbCaicatmNlAykNl","pdf",134374,3,1,4,"English","en",105,"# Electro-Optical Absolute Encoders with PROFIBUS-DP-Interface\n## Series overview and key features\n## Variants and connection methods (L and Z)\n## Construction and system stabilization\n## General connection features and PROFIBUS protocol\n## Electrical data and interface\n## Mechanical data\n## Bus data, diagnostics, and configuration\n## Diagnosis LED indicators and operating modes","[{\"question\":\"What measurement ranges and resolutions are supported by the KBD 58 and KRD 58 series?\",\"answer\":\"KBD 58 provides singleturn absolute measurement with a 360° range. KRD 58 supports multiturn absolute measurement up to 4096 revolutions, with total position capacity stated as 228 (28 bits) and resolutions from 12 to 16 bits.\"},{\"question\":\"How does the encoder connect to a PROFIBUS-DP bus and what protocol class is supported?\",\"answer\":\"The encoders are designed to connect directly as PROFIBUS-DP slave stations, implemented with a SPC3 Siemens PROFIBUS controller. The protocol follows DP-slave class 2 functionality as described for encoders in the referenced Profibus profile.\"},{\"question\":\"What differences exist between variant L and variant Z regarding addressing and bus termination?\",\"answer\":\"Variant L uses a round connector, and the default station address is changed via the DDLM_Set_Slave_Add service, with bus-termination resistors installed externally. Variant Z uses a connecting cap with DIP switches to set station address and termination resistances, and it also provides integrated addressing via T-coupler functionality.\"}]","Electro-Optical Absolute Encoders with PROFIBUS-DP-Interface - KBD 58 and KRD 58 series - Issue 01 / 2005 | PDF",1789010951,10,{"code":4,"msg":32,"data":33},"ok",{"site_id":25,"language":24,"slug":34,"title":13,"keywords":35,"description":14,"schema_data":36,"social_meta":86,"head_meta":88,"extra_data":90,"updated_unix":29},"electro-optical-absolute-encoders-with-profibus-dp-interface-kbd-58-and-krd-58-series-issue-01-2005","",{"@graph":37,"@context":85},[38,53,68],{"@type":39,"itemListElement":40},"BreadcrumbList",[41,45,49,51],{"item":42,"name":43,"@type":44,"position":21},"https://docshare.wps.com","Home","ListItem",{"item":46,"name":47,"@type":44,"position":48},"https://docshare.wps.com/document/","Document",2,{"item":50,"name":12,"@type":44,"position":20},"https://docshare.wps.com/document/technology/",{"item":52,"name":13,"@type":44,"position":22},"https://docshare.wps.com/document/electro-optical-absolute-encoders-with-profibus-dp-interface-kbd-58-and-krd-58-series-issue-01-2005/227624/",{"url":52,"name":13,"@type":54,"author":55,"headline":13,"publisher":57,"fileFormat":60,"inLanguage":24,"description":14,"dateModified":61,"datePublished":62,"encodingFormat":60,"isAccessibleForFree":63,"interactionStatistic":64},"DigitalDocument",{"name":9,"@type":56},"Person",{"url":42,"name":58,"@type":59},"DocShare","Organization","application/pdf","2026-09-11","2026-09-10",true,{"@type":65,"interactionType":66,"userInteractionCount":20},"InteractionCounter",{"@type":67},"ViewAction",{"@type":69,"mainEntity":70},"FAQPage",[71,77,81],{"name":72,"@type":73,"acceptedAnswer":74},"What measurement ranges and resolutions are supported by the KBD 58 and KRD 58 series?","Question",{"text":75,"@type":76},"KBD 58 provides singleturn absolute measurement with a 360° range. KRD 58 supports multiturn absolute measurement up to 4096 revolutions, with total position capacity stated as 228 (28 bits) and resolutions from 12 to 16 bits.","Answer",{"name":78,"@type":73,"acceptedAnswer":79},"How does the encoder connect to a PROFIBUS-DP bus and what protocol class is supported?",{"text":80,"@type":76},"The encoders are designed to connect directly as PROFIBUS-DP slave stations, implemented with a SPC3 Siemens PROFIBUS controller. The protocol follows DP-slave class 2 functionality as described for encoders in the referenced Profibus profile.",{"name":82,"@type":73,"acceptedAnswer":83},"What differences exist between variant L and variant Z regarding addressing and bus termination?",{"text":84,"@type":76},"Variant L uses a round connector, and the default station address is changed via the DDLM_Set_Slave_Add service, with bus-termination resistors installed externally. Variant Z uses a connecting cap with DIP switches to set station address and termination resistances, and it also provides integrated addressing via T-coupler functionality.","https://schema.org",{"og:url":52,"og:type":87,"og:title":13,"og:site_name":58,"og:description":14},"article",{"robots":89,"canonical":52},"index,follow",{"doc_id":7,"site_id":25},{"code":4,"msg":5,"data":92},[93,97,101,105,110,113,118,123,128,131,134],{"id":21,"doc_module":4,"doc_module_name":47,"category_name":94,"show_sort_weight":95,"slug":96},"Story & Novel",90,"story-novel",{"id":48,"doc_module":4,"doc_module_name":47,"category_name":98,"show_sort_weight":99,"slug":100},"Literature",80,"literature",{"id":22,"doc_module":4,"doc_module_name":47,"category_name":102,"show_sort_weight":103,"slug":104},"Exam",70,"exam",{"id":106,"doc_module":4,"doc_module_name":47,"category_name":107,"show_sort_weight":108,"slug":109},5,"Comic",60,"comic",{"id":11,"doc_module":4,"doc_module_name":47,"category_name":12,"show_sort_weight":111,"slug":112},50,"technology",{"id":114,"doc_module":4,"doc_module_name":47,"category_name":115,"show_sort_weight":116,"slug":117},7,"Healthcare",40,"healthcare",{"id":119,"doc_module":4,"doc_module_name":47,"category_name":120,"show_sort_weight":121,"slug":122},8,"Research & Report",30,"research-report",{"id":124,"doc_module":4,"doc_module_name":47,"category_name":125,"show_sort_weight":126,"slug":127},9,"Religion & Spirituality",20,"religion-spirituality",{"id":126,"doc_module":4,"doc_module_name":47,"category_name":129,"show_sort_weight":126,"slug":130},"World Cup","world-cup",{"id":30,"doc_module":4,"doc_module_name":47,"category_name":132,"show_sort_weight":30,"slug":133},"Lifestyle","lifestyle",{"id":135,"doc_module":4,"doc_module_name":47,"category_name":136,"show_sort_weight":106,"slug":137},19,"General","general"]