[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-detail-150164-en":3,"doc-seo-150164-105":30,"detail-sidebar-cat-0-en-105":91},{"code":4,"msg":5,"data":6},0,"success",{"doc_id":7,"user_id":8,"nickname":9,"user_avatar":10,"doc_module":4,"category_id":11,"category_name":12,"doc_title":13,"doc_description":14,"doc_content":15,"file_id":16,"file_url":17,"file_type":18,"file_size":19,"view_count":4,"is_deleted":4,"is_public":20,"is_downloadable":20,"audit_status":20,"page_count":21,"language":22,"language_code":23,"site_id":24,"html_lang":23,"table_of_contents":25,"faqs":26,"seo_title":27,"seo_description":14,"update_tm":28,"read_time":29},150164,962085662650,"Dozel","https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0",6,"Technology","Electro-Mechanical Diaphragm Dosing Pumps - EMD Series - Technical Specifications - Overview","Electro-Mechanical Diaphragm dosing pumps for transferring defined liquids between containers or into process lines, including open containers, closed containers, and pressure piping. AnTech solutions use microcontroller control and solenoid technology to achieve dosing precision below 0.1 ml, with flow options up to 25 L/h at 5 bar counter pressure and up to 3.5 L/h at 20 bar. The EMD series includes mechanical diaphragm models for broader flow ranges under varying counter pressure, plus configurable pump-head materials and dosing capacity control via manual settings and 4–20 mA input.","Electro-Mechanical Diaphragm  \nDosing Pumps  \n[www.](www.enelsa.com)[enelsa](www.enelsa.com)[.com](www.enelsa.com)  \nDosing Pumps  \nDosing pumps are used for the transfer of an identified liquid. This transfer is usually provided from one container to another container or process. Dosing pumps allow transfers to open containers, closed containers and pressure lines.  \nWith its high-precision microcontroller control and solenoid technology, AnTech dosing pumps offer models that can provide dosing with a precision of less than 0.1 ml. The models are available which can provide dosing up to 25 liters per hour at a counter pressure of 5 bars for high dosing needs and up to 3.5 liters per hour at a counter pressure of 20 bars for high-pressure dosing needs.  \nFor mechanical diaphragm dosing pumps, it offers a wide range of products which can provide dosing up to between 1.4-14 and 4.9-49 liters per hour at a counter pressure of 5 bars and up to between 5-50 and 15-150 liters per hour ata counter pressure of 7 bars.  \nEMD Series  \nEMD Series  \n[www.](www.enelsa.com)[enelsa](www.enelsa.com)[.com](www.enelsa.com)   \nElectro-Mechanical Diaphragm Dosing Pumps EMD Series  \nEMD-P  \nElectro-Mechanical Diaphragm Dosing Pump with Plastic Body  \n• Ideal solution for precise dosing of large quantities of liquid chemicals  \n• PP, SS 316 and PVDF pump head, couplings and check valves which can be selected according to the chemicals want to be dosed  \n• Manual 0-100% capacity setting when running or stopping.  \n• Ability to adjust capacity with the 4-20mA signal input motor driver  \nStock Code Model Lt/H  \nMax. Counter Pressure/Bar  \nPackage Sizes/cm  \nW-L-H  \nPacked Weight/Kg  \n\n| 311014005241(XXX)  EMD P14L/5B 380 (XXX) | 14 | 5 | 31 x 38 x 23 |\n| --- | --- | --- | --- |\n\n\n| 311032005251(XXX)  EMD P32L/5B 380 (XXX)\u003Cbr>32\u003Cbr>5\u003Cbr>31 x 38 x 23 |  |  |  |\n| --- | --- | --- | --- |\n| 311049005261(XXX)  EMD P49L/5B 380 (XXX) | 49 | 5 | 31 x 38 x 23 |\n\n5,90 (PCP)  \n5,95 (PSS)  \n6,10 (PVCCP)  \n6,00 (PVDFCP)  \n7,40 (SSS)  \nSpare Parts-Options  \nIncluded in  \nStock Code Stock Name Description Package  \n|  | 600112000440000 | CONNECTION KIT EMD 44 (PVCCP) | 9X12 mm And 20 mm Connection Parts Of The Emd Pump Head. For All Pvccp Models. | |\n| --- | --- | --- | --- | --- |\n\n410160011100001  \nCONNECTION KIT EMD 9X12 PP  \nPp Suction And Injection Kit For 9X12 mm Connection. For All Pcp Models  \n|  | 410160012200001 | CONNECTION KIT EMD 20MM PP | Pp Suction And Injection Kit For 20 mm Connection. For All Pcp Models | |\n| --- | --- | --- | --- | --- |\n\n410160021100001  \nCONNECTION KIT EMD PVC 9X12MM  \nPp Suction And Injection Kit For 9X12 mm Connection. For All Pvccp Models  \n|  | 410160022200001 | CONNECTION KIT EMD 20MM PVC | Pp Suction And Injection Kit For 20 mm Connection. For All Pvccp Models | |\n| --- | --- | --- | --- | --- |\n\n410160031300001  \nCONNECTION KIT EMD PVDF 9X12MM  \nPp Suction And Injection Kit For 9X12 mm Connection. For All Pvdf Models  \n|  | 410160032300001 | CONNECTION KIT EMD PVDF 20MM PVC | Pp Suction And Injection Kit For 20 mm Connection. For All Pvdf Models | |\n| --- | --- | --- | --- | --- |\n\n\n|  | 600112000110000 | CONNECTION KIT EMD 11 (PCP) | 9X12 mm And 20 mm Connection Parts Of The Emd Pump Head. For All Pcp Models. | |\n| --- | --- | --- | --- | --- |\n\n600112000330000  \nCONNECTION KIT EMD 33 (PVDFCP)  \n9X12 mm And 20 mm Connection Parts Of The Emd Pump Head. For All Pvdfcp Models.  \n| 410170011100001 | PIPE KIT 9X12 PE 10M | 9X12 mm Polyethylene Hose 10 Meters |\n| --- | --- | --- |\n\nElectro-Mechanical Diaphragm Dosing Pumps EMD Series  \nEMD-P TECHNICAL SPECIFICATIONS  \n| EMD P14L/5B 380 (XXX)  66 | 42 | 50 | 0,23 | 0,28 | 14 | 17 | 5 | 72,5 | 4 | 0,09 | 3/4” |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n\n\n| EMD P32/5B 380 (XXX)  66\u003Cbr>85\u003Cbr>102\u003Cbr>0,53\u003Cbr>0,64\u003Cbr>32\u003Cbr>38\u003Cbr>5\u003Cbr>72,5\u003Cbr>4\u003Cbr>0,09\u003Cbr>3/4” |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | ","cbCaimA6WGCAlobq","https://ap.wps.com/l/cbCaimA6WGCAlobq","pdf",1332205,1,8,"English","en",105,"# Dosing Pump Applications\n# EMD Series Overview\n## Control Precision and Dosing Capability\n# EMD-P Models and Features\n## Materials and Capacity Adjustment\n# EMD-M Models and Features\n# Spare Parts and Options\n## Connection Kits\n# Technical Specifications\n## Dimensions and Codes","[{\"question\":\"What liquids can EMD dosing pumps transfer and where are they used?\",\"answer\":\"EMD dosing pumps transfer identified liquids between containers or into process lines. They support transfers to open containers, closed containers, and pressure lines.\"},{\"question\":\"How precise is the dosing control in the EMD series?\",\"answer\":\"The described AnTech dosing pumps provide precision of less than 0.1 ml using microcontroller control and solenoid technology.\"},{\"question\":\"How is dosing capacity adjusted on the EMD pumps?\",\"answer\":\"Capacity can be set manually from 0–100% during running or stopping, and it can also be adjusted using a 4–20 mA signal input motor driver.\"}]","Electro-Mechanical Diaphragm Dosing Pumps - EMD Series - Technical Specifications - Overview | PDF",1787815036,20,{"code":4,"msg":31,"data":32},"ok",{"site_id":24,"language":23,"slug":33,"title":13,"keywords":34,"description":14,"schema_data":35,"social_meta":86,"head_meta":88,"extra_data":90,"updated_unix":28},"electro-mechanical-diaphragm-dosing-pumps-emd-series-technical-specifications-overview","",{"@graph":36,"@context":85},[37,54,68],{"@type":38,"itemListElement":39},"BreadcrumbList",[40,44,48,51],{"item":41,"name":42,"@type":43,"position":20},"https://docshare.wps.com","Home","ListItem",{"item":45,"name":46,"@type":43,"position":47},"https://docshare.wps.com/document/","Document",2,{"item":49,"name":12,"@type":43,"position":50},"https://docshare.wps.com/document/technology/",3,{"item":52,"name":13,"@type":43,"position":53},"https://docshare.wps.com/document/electro-mechanical-diaphragm-dosing-pumps-emd-series-technical-specifications-overview/150164/",4,{"url":52,"name":13,"@type":55,"author":56,"headline":13,"publisher":58,"fileFormat":61,"inLanguage":23,"description":14,"dateModified":62,"datePublished":62,"encodingFormat":61,"isAccessibleForFree":63,"interactionStatistic":64},"DigitalDocument",{"name":9,"@type":57},"Person",{"url":41,"name":59,"@type":60},"DocShare","Organization","application/pdf","2026-08-27",true,{"@type":65,"interactionType":66,"userInteractionCount":4},"InteractionCounter",{"@type":67},"ViewAction",{"@type":69,"mainEntity":70},"FAQPage",[71,77,81],{"name":72,"@type":73,"acceptedAnswer":74},"What liquids can EMD dosing pumps transfer and where are they used?","Question",{"text":75,"@type":76},"EMD dosing pumps transfer identified liquids between containers or into process lines. They support transfers to open containers, closed containers, and pressure lines.","Answer",{"name":78,"@type":73,"acceptedAnswer":79},"How precise is the dosing control in the EMD series?",{"text":80,"@type":76},"The described AnTech dosing pumps provide precision of less than 0.1 ml using microcontroller control and solenoid technology.",{"name":82,"@type":73,"acceptedAnswer":83},"How is dosing capacity adjusted on the EMD pumps?",{"text":84,"@type":76},"Capacity can be set manually from 0–100% during running or stopping, and it can also be adjusted using a 4–20 mA signal input motor driver.","https://schema.org",{"og:url":52,"og:type":87,"og:title":13,"og:site_name":59,"og:description":14},"article",{"robots":89,"canonical":52},"index,follow",{"doc_id":7,"site_id":24},{"code":4,"msg":5,"data":92},[93,97,101,105,110,113,118,122,126,129,133],{"id":20,"doc_module":4,"doc_module_name":46,"category_name":94,"show_sort_weight":95,"slug":96},"Story & Novel",90,"story-novel",{"id":47,"doc_module":4,"doc_module_name":46,"category_name":98,"show_sort_weight":99,"slug":100},"Literature",80,"literature",{"id":53,"doc_module":4,"doc_module_name":46,"category_name":102,"show_sort_weight":103,"slug":104},"Exam",70,"exam",{"id":106,"doc_module":4,"doc_module_name":46,"category_name":107,"show_sort_weight":108,"slug":109},5,"Comic",60,"comic",{"id":11,"doc_module":4,"doc_module_name":46,"category_name":12,"show_sort_weight":111,"slug":112},50,"technology",{"id":114,"doc_module":4,"doc_module_name":46,"category_name":115,"show_sort_weight":116,"slug":117},7,"Healthcare",40,"healthcare",{"id":21,"doc_module":4,"doc_module_name":46,"category_name":119,"show_sort_weight":120,"slug":121},"Research & Report",30,"research-report",{"id":123,"doc_module":4,"doc_module_name":46,"category_name":124,"show_sort_weight":29,"slug":125},9,"Religion & Spirituality","religion-spirituality",{"id":29,"doc_module":4,"doc_module_name":46,"category_name":127,"show_sort_weight":29,"slug":128},"World Cup","world-cup",{"id":130,"doc_module":4,"doc_module_name":46,"category_name":131,"show_sort_weight":130,"slug":132},10,"Lifestyle","lifestyle",{"id":134,"doc_module":4,"doc_module_name":46,"category_name":135,"show_sort_weight":106,"slug":136},19,"General","general"]