[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-665490-105":59,"doc-detail-665490-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","electrical-one-line-diagram","Electrical One-Line Diagram","","Electrical one-line diagram showing electrical distribution components and interconnections, including primary power conversion from 13,200V to 120/208V, utility metering, and transformer and feeder arrangements. The layout includes main switchboard (MSB) and multiple distribution panels (e.g., 1CDP1, XCRDP, 1ADP1, and XLS) with specified current ratings, phases, and spare breakers. General notes cover coordination for HVAC conductor sizes via a referenced schedule, alternate switchboard arrangements, CT location and meter mounting requirements, plus a feeder wire size schedule by quantity and conductor/ground combinations.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/electrical-one-line-diagram/665490/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/electrical-one-line-diagram/665490.png","ImageObject",300,407,{"name":92,"@type":93},"eBook King","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What voltage transformation is shown at the start of the one-line diagram?","Question",{"text":112,"@type":113},"The diagram indicates power company transformers converting 13,200V to 120/208V.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which equipment is identified as the main switchboard (MSB)?",{"text":117,"@type":113},"The main switchboard is labeled \"MSB\" and shown with a 3000A, 120Y/208V, 3PH, 4W configuration.",{"name":119,"@type":110,"acceptedAnswer":120},"What is included in the general notes section of the diagram?",{"text":121,"@type":113},"The general notes specify references for conductor sizing schedules, alternates for additional switchboard and solid-state breakers, coordination for CT and meter placement, and an aluminum feeder wire size schedule listing quantities and conductor/ground configurations.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},665490,1793304492,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},962088006270,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","11/14/20 13 12 : 1 1 :55 PM  \n\n| \u003Cbr>PRIMARY CABLE INSTALLED BY POWER CO.\u003Cbr>POWER CO. TRANSFORMER 13,200V TO 120/208V.\u003Cbr>CT'S BY POWER CO.\u003Cbr>1\u003Cbr>3000A\u003Cbr>1\u003Cbr>MAIN SWITCHBOARD \"MSB\"\u003Cbr>3000A 120Y/208V-3PH-4W\u003Cbr>9\u003Cbr>60A 200A 800A 1000A 1000A 225A 225A 400A 80A 60A 50A\u003Cbr>50A 200A 200A 200A\u003Cbr>SPARE SPARE SPARE\u003Cbr>2\u003Cbr>3\u003Cbr>4 4 5\u003Cbr>SERVICE\u003Cbr>300KW 208Y/120V\u003Cbr>3 3\u003Cbr>3P-200A\u003Cbr>1\u003Cbr>LIFE SAFETY ATS-2\u003Cbr>4-POLE\u003Cbr>3P-800A\u003Cbr>200A\u003Cbr>1\u003Cbr>2\u003Cbr>CRITICAL ATS-1 4-POLE\u003Cbr>1\u003Cbr>2\u003Cbr>800A\u003Cbr>2\u003Cbr>\"1B1\" \"1B2\" \"1KB\"\u003Cbr>RTU-1 RTU-2 RTU-5 RTU-6\u003Cbr>DISTRIBUTION PANEL \"1CDP1\"\u003Cbr>1000A 120Y/208V-3PH-4W\u003Cbr>225A 225A 300A 225A 300A 225A 100A 100A\u003Cbr>SPARE SPARE\u003Cbr>4 4 6 4 6 4\u003Cbr>DISTRIBUTION PANEL \"XCRDP\"\u003Cbr>800A 120Y/208V-3PH-4W\u003Cbr>200A 200A 200A 200A 400A 250A\u003Cbr>7 7 7 7 5 6\u003Cbr>90A 60A\u003Cbr>100A\u003Cbr>SPARE\u003Cbr>\"1C1\" \"1C3\"\u003Cbr>\"1C2\" \"1C4\"\u003Cbr>DISTRIBUTION PANEL \"1ADP1\"\u003Cbr>1000A 120Y/208V-3PH-4W\u003Cbr>\"2C1\"\u003Cbr>\"2C2\"\u003Cbr>225A 225A 225A 225A 225A 225A 225A 100A 100A\u003Cbr>SPARE SPARE\u003Cbr>4 4 4 4 4 4 4\u003Cbr>\"1XCRB1\" \"2XCRC1\"\u003Cbr>\"1XCRA1\" \"1XCRC1\"\u003Cbr>PANEL \"XLS\"\u003Cbr>200A 120Y/208V-3PH-4W\u003Cbr>\"2XCRA1\"\u003Cbr>ELEVATOR\u003Cbr>POWER SWITCH\u003Cbr>ELEVATOR\u003Cbr>RTU-4 RTU-3\u003Cbr>\"1A1\" \"1A3\"\u003Cbr>\"1A2\"\u003Cbr>\"1A4\"\u003Cbr>\"2A1\" \"2A3\"\u003Cbr>\"2A2\"\u003Cbr>100A 100A\u003Cbr>8 8\u003Cbr>\"1XLSC1\"\u003Cbr>\"1XLSA1\"\u003Cbr>\u003Cbr>POWER CO. SOURCE 12470Y/7200V\u003Cbr>POWER CO. METER4 \u003Cbr>\u003Cbr>\"2XLSC1\"\u003Cbr>1 ~~ ~~c1'c-0\"al~~ ~~One-Line~~ ~~Diagram~~ ~~\u003Cbr>\u003Cbr>GENERAL NOTES\u003Cbr>A. SEE MOTORS, STARTERS, DISCONNECTS AND CONTROLS SCHEDULE ON SHEET E602 FOR HVAC EQUIPMENT CONDUCTOR SIZES.\u003Cbr> NOTES\u003Cbr>1. ALTERNATE \\#3: PROVIDE 2000A SWITCHBOARD AND 2000A 100% RATED SOLID STATE MAIN BREAKER.\u003Cbr>2. ALTERNATE \\#3: PROVIDE 6 SETS OF 4- \\#600,\u003Cbr>\\#250GRD. , 4\"C.\u003Cbr>3. SECONDARY TERMINATION CABINET PROVIDE BY\u003Cbr>E.C. LOCATE CT'S IN TERMINATION CABINET. COORDINATE REQUIREMENTS WITH UTILITY CO.\u003Cbr>4. MOUNT METER ON TERMINATION CABINET. COORDINATE REQUIREMENTS WITH UTILITY CO.\u003Cbr>ALUMINUM FEEDER WIRE SIZE SCHEDULE 1 4- \\#250, 1- \\#6GRD. , 3\"C 2 3 SETS OF 4- \\#400, 1- \\#1/0GRD. , 3\"C 3 4 SETS OF 4- \\#400, 1- \\#2/0GRD. , 3\"C 4 4- \\#300, 1- \\#2GRD. , 3\"C 5 2 SETS OF 4- \\#250, 1- \\#3GRD. , 3\"C 6 4- \\#500, 1- \\#4GRD. , 3.5\"C 7 4- \\#250, 1- \\#6GRD. , 3\"C 8 4- \\#1, 1- \\#6GRD. , 2\"C 9 8 SETS OF 4- \\#750, 4\"C | \u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>ISSUANCE INDEX DATE: 7/24/13 PROJECT PHASE: CONSTRUCTION DOCUMENTS\u003Cbr>REVISION SCHEDULE NO. DESCRIPTION DATE City Submittal 9/18/13 2 ADDENDUM NO. 2 8/01/13 6 Issued for Construction 11/14/13\u003Cbr>Project Number 2012.02161\u003Cbr>ELECTRICAL ONE-LINE DIAGRAM\u003Cbr>E601 |\n| --- | --- |","cbCaieuaAKgUL8Kt","https://ap.wps.com/l/cbCaieuaAKgUL8Kt","pdf",319589,"English","# Electrical one-line diagram overview\n## Main switchboard and transformer ratings\n## Distribution panels and RTU/Life safety ATS\n## General notes and feeder wire size schedule","[{\"question\":\"What voltage transformation is shown at the start of the one-line diagram?\",\"answer\":\"The diagram indicates power company transformers converting 13,200V to 120/208V.\"},{\"question\":\"Which equipment is identified as the main switchboard (MSB)?\",\"answer\":\"The main switchboard is labeled \\\"MSB\\\" and shown with a 3000A, 120Y/208V, 3PH, 4W configuration.\"},{\"question\":\"What is included in the general notes section of the diagram?\",\"answer\":\"The general notes specify references for conductor sizing schedules, alternates for additional switchboard and solid-state breakers, coordination for CT and meter placement, and an aluminum feeder wire size schedule listing quantities and conductor/ground configurations.\"}]","Electrical One-Line Diagram | PDF"]