[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-337822-105":59,"doc-detail-337822-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","electrical-lymph-node-scanning-els-system-for-real-time-intra-operative-detection-of-involved-axillary-lymph-nodes-in-adjuvant-breast-cancer-patients","Electrical lymph node scanning (ELS) system for real-time intra-operative detection of involved axillary lymph nodes in adjuvant breast cancer patients","","Lymph node status is a key prognostic factor in breast cancer and strongly influences surgical and therapeutic decision-making. A prospective blinded evaluation tested a real-time electrical lymph node scanning (ELS) system in non-chemo-treated patients, using permanent pathology as the gold standard and comparing ELS to intra-operative frozen-section pathology. Among 97 patients, 381 lymph nodes were scored, yielding high sensitivity for node-positive cases and significant diagnostic performance by ROC analysis. Increasing lymph node size correlated with higher ELS sensitivity, supporting clinical efficacy and potential reduction of unnecessary dissection.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/electrical-lymph-node-scanning-els-system-for-real-time-intra-operative-detection-of-involved-axillary-lymph-nodes-in-adjuvant-breast-cancer-patients/337822/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/electrical-lymph-node-scanning-els-system-for-real-time-intra-operative-detection-of-involved-axillary-lymph-nodes-in-adjuvant-breast-cancer-patients/337822.png","ImageObject",300,407,{"name":92,"@type":93},"Hazel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-09-21",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"How does the ELS system work in intra-operative axillary lymph node detection?","Question",{"text":112,"@type":113},"ELS provides real-time electrical scanning scores during surgery to assess lymph node involvement, which are calibrated and interpreted against pathological findings.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What gold standard was used to evaluate ELS accuracy?",{"text":117,"@type":113},"Permanent pathology served as the gold standard, while ELS and frozen-section results were generated intra-operatively for comparison.",{"name":119,"@type":110,"acceptedAnswer":120},"What were the main diagnostic performance findings of ELS?",{"text":121,"@type":113},"ELS showed high sensitivity for node-positive patients and significant ROC performance (AUC 0.878) versus the permanent pathology benchmark.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},337822,1790095422,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":52,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":19,"preview_urls":145},137441390410,"https://ap-avatar.wpscdn.com/avatar/2000252f4ab5702993?_k=1776741390130283984","[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nElectrical lymph node scanning (ELS) system for real‑time intra‑operative detection of involved axillary lymph nodes in adjuvant breast cancer patients  \nFereshteh Abbasvandi1,2,3,10, Reihane Mahdavi2,10, Mahdis Bayat2,  \nFarzane Hajighasemi2, Fahimeh Jahanbakhshi2, Faeze Aghaei2, Nafiseh Sami2,4, Batoul Khoundabi 5,6, Hossein Ataee2, Narges Yousefpour2, Parisa Hoseinpour1,7,  \nSeyed Mohamad Sadegh Mousavi Kiasary2, Maryam Omrani Hashemi3, Fatemeh Shojaeian2, AtiehAkbari3, Najmeh Bagherhosseini3, Afshin Moradi8, Mohammad Esmaeil Akbari3* & Mohammad Abdolahad2,9*  \nLymph node (LN) status is an essential prognostic factor in breast cancer (BC) patients, with an important role in the surgical and therapeutic plan. Recently, we have been developed a novel system for real‑time intra‑operative electrical LN scanning in BC patients. The ELS scores were calibrated by pathological evaluation ofthe LNs. Herein, we evaluated the efficacy of ELS in a prospective study for non‑chemo‑treated breast cancer patients. This is a prospective study in which ELS scores are blind for pathologists who declare the clearance or involvement of LNs based on permanent pathology asthe gold standard. ELS and frozen‑section (FS) pathology results were achieved intra‑operatively, and samples were sent for the permanent pathology. The score of ELS did not affect the surgeons’decision, and the treatment approach was carried out based on FS pathology and pre‑surgical data, such as imaging and probable biopsies. Patients were recruited from October 2021 through November 2022, and 381 lymph nodes of 97 patients were included in the study. In this study we recruited 38 patients (39.2%) with sentinel lymph node biopsy (SLNB) and 59 patients (60.8%) withALND. Of the 381 LNs scored by ELS, 329 sentinel LNs underwent routine pathology, while others (n = 52) underwent both FS and permanent pathology. ELS showed a sensitivity of 91.4% for node‑positive patients, decreasing to 84.8% when considering all LNs. Using ROC analysis, ELS diagnosis showed a significant AUC of 0.878 in relation to the permanent pathology gold standard. Comparison of ELS diagnosis for different tumor types and LN sizes demonstrated no significant differences, while increasing LN size correlated with enhanced ELS sensitivity. This study confirmed ELS’s efficacy in real‑time lymph node detection among non‑chemo‑treated breast cancer patients. The use of ELS’s pathological scoring for intra‑operative LN diagnosis, especially in the absence of FS pathology or for non‑sentinel LN involvement, could improve prognosis and reduce complications by minimizing unnecessary dissection.  \n1ATMP Department, Breast Cancer Research Center, Motamed Cancer Institute, ACECR, P.O. Box 1517964311, Tehran, Iran. 2Nano Bioelectronics Devices Lab, Cancer Electronics Research Group, School of Electrical and Computer Engineering, Faculty of Engineering, University of Tehran, Tehran, Iran. 3Cancer Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran. 4Student Research Committee, Faculty of Medicine, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran. 5Iran-Helal Institute of Applied Science and Technology, Red Crescent Society of Iran, Tehran, Iran. 6Research Center for Health Management in Mass Gathering, Red Crescent Society of the Islamic Republic of Iran, Tehran, Iran. 7SEPAS Pathology Laboratory, Tehran, Iran. 8Department of Pathology, Shohada Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran. 9Cancer Institute, Imam-Khomeini Hospital, Tehran University of Medical Sciences, Tehran, Iran. 10These authors contributed equally: Fereshteh Abbasvandi and Reihane Mahdavi. *[email: Me-akbari@sbmu.ac.ir](email: Me-akbari@sbmu.ac.ir); [m.abdolahad@ut.ac.ir](m.abdolahad@ut.ac.ir)  \n[www. nature.com/scientificreports/](www. nature.com/scientificreports/)  \nKeywords Breast cancer surgery, Nodal s","cbCaipUMK4PTHYfV","https://ap.wps.com/l/cbCaipUMK4PTHYfV","pdf",1353863,"English","# Introduction\n# Methods\n## Study design and patient cohort\n## ELS scoring and pathology comparison\n# Results\n## Diagnostic performance (sensitivity, ROC/AUC)\n## Effects of tumor type and lymph node size\n# Discussion\n## Clinical implications and potential to reduce morbidity","[{\"question\":\"How does the ELS system work in intra-operative axillary lymph node detection?\",\"answer\":\"ELS provides real-time electrical scanning scores during surgery to assess lymph node involvement, which are calibrated and interpreted against pathological findings.\"},{\"question\":\"What gold standard was used to evaluate ELS accuracy?\",\"answer\":\"Permanent pathology served as the gold standard, while ELS and frozen-section results were generated intra-operatively for comparison.\"},{\"question\":\"What were the main diagnostic performance findings of ELS?\",\"answer\":\"ELS showed high sensitivity for node-positive patients and significant ROC performance (AUC 0.878) versus the permanent pathology benchmark.\"}]","Electrical lymph node scanning (ELS) system for real-time intra-operative detection of involved axillary lymph nodes in adjuvant breast cancer patients | PDF",1790020800,25,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/0ce804953fd6f9c7f9bbf27683ea2024.webp",983,1291,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/462b0219ef56a07a13ada5cbd6f9b31a.webp",982,1290,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/3910e5c5bc512777c0068288c03a28eb.webp",981,1289,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/3e81545991e3166790e22d2cfed6908a.webp",980,1287]