[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-648688-105":59,"doc-detail-648688-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","electrical-list-of-drawings-electrical-package-general-notes","ELECTRICAL LIST OF DRAWINGS - Electrical Package - General Notes","","Electrical list of drawings for the MoL Nursery project, defining the electrical package scope and general installation requirements. Includes project and drawing identifiers (design, scale, date) and provides coordinated guidelines across architectural, structural, mechanical, and interior design disciplines. Covers conduit sizing, minimum conduit diameter, weatherproofing for outlets and switches, socket outlet specifications, routing rules for concealed and exposed conduits, equipment and lighting fixture coordination, earthing and grounding conductor requirements, and junction box provisions. Specifies approvals, shop drawing submissions, coordination with HVAC equipment, and electrical protection ratings such as MCB/ELCB/MCCB capacity and ACB interrupting capacity.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/electrical-list-of-drawings-electrical-package-general-notes/648688/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/electrical-list-of-drawings-electrical-package-general-notes/648688.png","ImageObject",300,407,{"name":92,"@type":93},"Stanford","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-24","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What coordination requirements are specified for the electrical drawings?","Question",{"text":112,"@type":113},"The document requires electrical drawings to be read together with relevant architectural, structural, mechanical, and interior design drawings and specifications, and states that conduit and equipment locations must be coordinated with other services.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the stated conduit and routing rules?",{"text":117,"@type":113},"It specifies conduit sizing in accordance with relevant B.S and local regulations, a minimum conduit size of Ø20mm, and routing rules such as concealed rising conduits running in walls or columns and exposed conduits being GI type.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the document address grounding and earthing?",{"text":121,"@type":113},"It requires an insulated green grounding conductor carried in all raceways, connection via suitable grounding lugs, earth continuity for cable trays using 6mm² copper wire, and connection of equipment to the ring earth system in accordance with relevant B.S requirements.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},648688,1792878106,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},2336477552062,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","MoL NURSERY PROJECT  \nElectrical Package  \n| | NOTES :\u003Cbr>1. Contractor shall submit shop drawings and materials submittals to the supervision team for their approval before installation and execution.\u003Cbr>2. The appearance of all visible items is applied to architect's approval.\u003Cbr>3. All dimensions are from structure to structure unless indicated otherwise. Elements of services indicated for coordination purposes. For full services layouts refer to Services Engineers drawings. Elements of structure indicated for coordination purposes. For full structure layouts refer to Structural Engineers drawings. Do not scale directly from drawing. All dimension to be checked on site prior to construction or fabrication of any elements. Any discrepancies between figured dimensions to be reported to architect for clarification prior to commencing work. |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  |  |  |  |\n|  | Purpose Of Issue |  | Rev. | Date Approved |  |  |\n|  | |  |  |  |  |  |\n|  | |  |  |  |  |  |\n|  | Project:\u003Cbr>MoL NURSERY |  |  |  |  |  |\n|  | Title:\u003Cbr>ELECTRICAL LIST OF DRAWINGS |  |  |  |  |  |\n|  | Design: MEPJO | Drawn by: MEPJO |  |  | Checked: MEPJO |  |\n|  | Scale / SIZE:\u003Cbr>1:50 / A1 | Date:\u003Cbr>APR. 2022 |  |  | Approved: MEPJO |  |\n|  | \u003Cbr>M E T E R S |  |  |  |  |  |\n|  | Drawing Number: E-001 |  |  |  |  | Rev.: |\n\n\n| GENERAL NOTES: 01- THE ELECTRICAL DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURAL, STRUCTURAL, MECHANICAL AND INTERIOR DESIGN DRAWINGS AND SPECIFICATIONS.\u003Cbr>02- DO NOT SCALE FROM THE ELECTRICAL DRAWING LAYOUTS, WORK ACCORDING TO ARCHITECTURAL AND ELECTRICAL DETAILS.\u003Cbr>03- CONDUIT SIZES SHALL BE SELECTED IN ACCORDANCE WITH THE RELEVANT B.S REGULATIONS AND LOCAL REGULATIONS.\u003Cbr>04- MINIMUM CONDUIT SIZE TO BE Ø20mm.\u003Cbr>05- ALL OUTLETS, SWITCHES, BOXES, ISOLATING SWITCHES AND FITTINGS IN PLANT ROOMS AND/OR EXPOSED TO EXTERNAL ENVIRONMENT SHALL BE WEATHER PROOF.\u003Cbr>06- ALL SOCKET OUTLETS SHALL BE 3-PIN SWITCHED COMBINED TYPE WITH INDICATION LAMP UNLESS OTHERWISE INDICATED.\u003Cbr>07- ALL SOCKET OUTLETS SHALL BE MINIMUM OF 13 AMPERE RATED UNLESS OTHERWISE INDICATED.\u003Cbr>08- ALL CONCEALED RISING CONDUITS SHALL RUN IN THE WALLS OR COLUMNS, CONDUITS SHALL NOT RUN IN PLASTER, ALL RECESSED CONDUITS SHALL BE PVC TYPE ALL SURFACE/ EXPOSED CONDUITS SHALL BE GI TYPE.\u003Cbr>09- EXACT LOCATION OF ALL MECHANICAL / HVAC EQUIPMENT AND ASSOCIATED DISCONNECTING SWITCHES AND OUTLETS SHALL BE COORDINATED WITH THE MECHANICAL DRAWINGS.\u003Cbr>10- CONTRACTOR SHALL ESTABLISH EXACT LOCATION OF LIGHTING FIXTURES, SMOKE DETECTORS, CABLE TRAYS, CABLE ROUTES, CONDUIT ROUTES ...etc. IN FULL COORDINATION WITH OTHER SERVICES AND TO THE ENGINEER APPROVAL.\u003Cbr>11- LOCATION OF EARTH ELECTRODES AND DOWN CONDUCTORS SHALL BE COORDINATED WITH MANHOLES & SERVICES FOR OTHER TRADES.\u003Cbr>12- ALL LIGHT FIXTURES SHALL BE SUPPLIED COMPLETE WITH CONTROL GEAR INCLUDING POWER FACTOR CAPACITORS WHERE NECESSARY AND LAMP WHETHER EXPLICITLY MENTIONED OR NOT.\u003Cbr>13- LIGHTING FIXTURE IN MECHANICAL ROOMS, SUBSTATION, GENERATOR ROOM ... etc. THE MINIMUM SIZE ALLOWED BY THE CODES AND MAY BE PURPOSELY OVERSIZED TO CONDUIT ...etc. AND BE SUSPENDED WHERE REQUIRED.\u003Cbr>14- CONDUIT SIZES CALLED OUT ON THE DRAWINGS ARE NOT NECESSARILY BASED ON THE MINIMUM SIZE ALLOWED BY THE CODES AND MAY BE PURPOSELY OVERSIZED TO AVOID EXCESS CONDUIT HEATING AND VOLTAGE DROP.\u003Cbr>15- ALL CIRCUITS SHALL INCLUDE AN INSULATED GREEN GROUNDING CONDUCTOR. THIS CONDUCTOR SHALL BE CARRIED IN ALL RACEWAYS INCLUDING THOSE INSTALLED FOR SWITCH LUGS AND SHALL BE CONNECTED TO THE DEVICE, LUMINARIES, SOCKET OUTLET OR EQUIPMENT HOUSING USING A SUITABLE GROUNDING LUG.\u003Cbr>16- THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL JUNCTION BOXES REQUIRED FOR EQUIPMENT, WHETHER OR NOT SPECIFICALLY INDICATED ON THE PLANS.\u003Cbr>17- ALL FLUSH MOUNTED PANELS IN THE PROJECT SHALL HAVE THE REQUIRED NUMBER OF Ø 25mm CONDUITS EXTENDED TO ABOVE AN ACCESSIBLE CEILING FOR FUTURE USE.\u003Cbr>18","cbCaiop4OaMuvoZf","https://ap.wps.com/l/cbCaiop4OaMuvoZf","pdf",1992080,"English","# General Notes\n## Project and drawing information\n## Coordination requirements\n## Conduit, outlets, and wiring rules\n## Lighting, equipment, and approvals\n## Earthing, cables, and electrical ratings","[{\"question\":\"What coordination requirements are specified for the electrical drawings?\",\"answer\":\"The document requires electrical drawings to be read together with relevant architectural, structural, mechanical, and interior design drawings and specifications, and states that conduit and equipment locations must be coordinated with other services.\"},{\"question\":\"What are the stated conduit and routing rules?\",\"answer\":\"It specifies conduit sizing in accordance with relevant B.S and local regulations, a minimum conduit size of Ø20mm, and routing rules such as concealed rising conduits running in walls or columns and exposed conduits being GI type.\"},{\"question\":\"How does the document address grounding and earthing?\",\"answer\":\"It requires an insulated green grounding conductor carried in all raceways, connection via suitable grounding lugs, earth continuity for cable trays using 6mm² copper wire, and connection of equipment to the ring earth system in accordance with relevant B.S requirements.\"}]","ELECTRICAL LIST OF DRAWINGS - Electrical Package - General Notes | PDF",1792794616,18]