[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-462941-105":59,"doc-detail-462941-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","electric-field-driven-melt-jetting-polycaprolactone-rotational-printing-of-fully-degradable-vascular-stents-abstract","Electric Field-Driven Melt Jetting Polycaprolactone Rotational Printing of Fully Degradable Vascular Stents - Abstract","","Electric field-driven melt jetting rotational printing enables fabrication of polycaprolactone (PCL) biodegradable vascular scaffolds (Ø3–8 mm) aimed at personalized fabrication and mechanical regulation. Multiscale characterization shows a rhombic mesh macrostructure with uniform fibers and fusion-enhanced nodal junctions controlled by electrohydrodynamic forces and surface tension during microfiber deposition. Tensile testing reveals triphasic behavior and size-dependent strength, while fractography distinguishes brittle initiation at stress-concentrated nodes from ductile dominance in straight segments. Compression results confirm load-holding-recovery behavior with improved load capacity and elastic recovery, supporting structure–property optimization for degradable vascular implants and clinical compatibility.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/electric-field-driven-melt-jetting-polycaprolactone-rotational-printing-of-fully-degradable-vascular-stents-abstract/462941/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/electric-field-driven-melt-jetting-polycaprolactone-rotational-printing-of-fully-degradable-vascular-stents-abstract/462941.png","ImageObject",300,407,{"name":92,"@type":93},"Bulrr","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-12","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",13,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What technique does the study introduce for fabricating degradable vascular scaffolds?","Question",{"text":113,"@type":114},"The study pioneers an electric field-driven melt jetting rotational printing technique to fabricate polycaprolactone (PCL) scaffolds with diameters of Ø3–8 mm.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does multiscale characterization describe the scaffold structure?",{"text":118,"@type":114},"It confirms a rhombic mesh macrostructure with uniform fibers and fusion-enhanced nodal junctions, linked to synergistic control of electrohydrodynamic forces and surface tension during deposition.",{"name":120,"@type":111,"acceptedAnswer":121},"What mechanical and fracture behaviors are observed in tensile testing?",{"text":122,"@type":114},"Mechanical testing shows triphasic tensile behavior, with 5 mm scaffolds displaying a higher peak load due to better interfacial bonding and denser geometry, while 8 mm scaffolds fail prematurely. Fractography indicates brittle fracture initiation at stress-concentrated nodes and ductile dominance in straight segments.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},462941,1790813203,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},5909892115043,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Article  \nElectric Field-Driven Melt Jetting Polycaprolactone Rotational Printing of Fully Degradable Vascular Stents and Mechanical Characterization  \nYanpu Chao 1, *, Fulai Cao 1, Hao Yi 2, *, Shuai Lu 1, Chengyan Zhang 1, Hui Cen 1, Zhongfu Liu 1, Yihang Yao 1 and Xiaobo Zhao 1  \nAcademic Editor: Yi-JeJuang  \nReceived: 26 November 2025  \nRevised: 22 December 2025  \nAccepted: 24 December 2025  \nPublished: 26 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 School of Mechatronics Engineering, Xuchang University, Xuchang 461000, China  \n2 State Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing 400044, China  \n* Correspondence: [12014026@xcu.edu.cn](12014026@xcu.edu.cn) (Y.C.); [haoyi@cqu.edu.cn](haoyi@cqu.edu.cn) (H.Y.)  \nAbstract  \nAddressing technical challenges in personalized fabrication and mechanical regulation of bioresorbable vascular scaffolds, this study pioneers an electric field-driven melt jetting rotational printing technique to fabricate polycaprolactone (PCL) scaffolds (Ø3–8 mm) . Multiscale characterization confirms a rhombic mesh macrostructure with uniform fibers and fusion-enhanced nodal junctions, demonstrating synergistic control of electrohydrodynamic forces and surface tension over microfiber deposition. Mechanical testing reveals triphasic tensile behavior (elastic-plastic-fracture), where 5 mm scaffolds exhibit 38% enhanced peak load due to superior interfacial bonding and densified geometry, while 8 mm counterparts suffer premature failure from structural weakening. Fractography identifies brittle fracture initiation at stress-concentrated nodes versus ductile dominance in straight segments, confirming co-regulation by intrinsic material properties and architecture. Compression tests demonstrate characteristic load-holding-recovery behavior, with 20% increased load-bearing capacity and enhanced elastic recovery in larger scaffolds. This work establishes a structure–property correlation framework for optimizing degradable vascular implants, providing novel methodologies and theoretical foundations for clinical compatibility.  \nKeywords: vascular scaffolds; electric field-driven; rotational deposition; mechanical behavior; fracture mechanisms  \n1. Introduction  \nCoronary artery disease (CAD), among the most prevalent cardiovascular pathologies, primarily stems from atherosclerosis—the accumulation of cholesterol-rich plaques within arterial walls [1] . This process induces arterial narrowing and stiffening, which restricts or even blocks blood flow [2,3], ultimately causing myocardial damage. Current therapeutic interventions include pharmacotherapy, surgery, and catheter-based stent implantation. Percutaneous coronary intervention (PCI) with stenting is recognized as the most effective technique for CAD management, widely adopted due to its minimally invasive nature and enhanced procedural safety [4,5] . During PCI, a vascular stent is deployed at the lesionsite to dilate stenotic/occluded vessels and scaffold the arterial wall, thereby restoring physiological blood perfusion [6] .  \nBiodegradable polymeric vascular scaffolds (BPVS), representing the fourth-generation endovascular implants [7], offer distinct advantages over conventional bare-metal stents  \n(BMS) [8] and drug-eluting stents (DES) [9] . These include low mass, transient radial support, exceptional biocompatibility, superior processability, and controllable biodegradation [10] . Critically, BPVS eliminate complications associated with permanent metallic implants while minimizing physiological impact, establishing them as a promising alternative for safer interventional strategies.  \nAn ideal biodegradable polymeric vascular scaffold (BPVS) must possess essential biomechanical properties including sufficient radial strength, longitudinal fle","cbCaiqWSR52bfmod","https://ap.wps.com/l/cbCaiqWSR52bfmod","pdf",5936744,23,"English","# Abstract\n# Keywords\n# 1. Introduction","[{\"question\":\"What technique does the study introduce for fabricating degradable vascular scaffolds?\",\"answer\":\"The study pioneers an electric field-driven melt jetting rotational printing technique to fabricate polycaprolactone (PCL) scaffolds with diameters of Ø3–8 mm.\"},{\"question\":\"How does multiscale characterization describe the scaffold structure?\",\"answer\":\"It confirms a rhombic mesh macrostructure with uniform fibers and fusion-enhanced nodal junctions, linked to synergistic control of electrohydrodynamic forces and surface tension during deposition.\"},{\"question\":\"What mechanical and fracture behaviors are observed in tensile testing?\",\"answer\":\"Mechanical testing shows triphasic tensile behavior, with 5 mm scaffolds displaying a higher peak load due to better interfacial bonding and denser geometry, while 8 mm scaffolds fail prematurely. Fractography indicates brittle fracture initiation at stress-concentrated nodes and ductile dominance in straight segments.\"}]","Electric Field-Driven Melt Jetting Polycaprolactone Rotational Printing of Fully Degradable Vascular Stents - Abstract | PDF",1790765833,58,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/a1b66734493e7aa3a327f1963d0f7f72.webp",983,1390,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/3d07d62f854e13ebe4588713ec22a31c.webp",982,1388,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/69718efb5d077b87b9fe8c363a3c0714.webp",981,1387,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/d7bec29279f09789335e92592a9901b7.webp",980,1385]