[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-466212-105":59,"doc-detail-466212-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","effect-of-underwear-materials-on-the-thermal-insulation-of-barrier-protective-clothing","Effect of Underwear Materials on the Thermal Insulation of Barrier Protective Clothing","","Medical personnel wearing barrier clothing to protect against infectious agents face heat stress driven by reduced heat exchange with the environment. This study evaluated how changing underwear alters thermal insulation, water vapor resistance, and the expected safe working time for protective clothing sets. A Newton thermal manikin assessed clothing combinations using three underwear types under two barrier suit types. Physiological simulations in Predicted Heat Strain (PHS) estimated time to reach 38°C core temperature at 22°C and 35°C. Results showed a 24% increase in safe working time at 22°C and up to 4% at 35°C.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/effect-of-underwear-materials-on-the-thermal-insulation-of-barrier-protective-clothing/466212/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/effect-of-underwear-materials-on-the-thermal-insulation-of-barrier-protective-clothing/466212.png","ImageObject",300,407,{"name":92,"@type":93},"Terk","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",15,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What was the aim of the study?","Question",{"text":113,"@type":114},"To assess how changing underwear affects the thermal parameters of barrier protective clothing and the expected safe working time.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How were thermal insulation and water vapor resistance measured?",{"text":118,"@type":114},"Thermal insulation and water vapor resistance were determined using a Newton thermal manikin for clothing sets combining three underwear types with two barrier suit types.",{"name":120,"@type":111,"acceptedAnswer":121},"How did underwear changes influence safe working time at 22°C and 35°C?",{"text":122,"@type":114},"At 22°C, replacing medical underwear with thermal underwear extended safe working time by 24%. At 35°C, the benefit was smaller, extending working time by up to 4%.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},466212,1790972066,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":46,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":31,"preview_page_count":19,"preview_urls":145},1099525198933,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Article  \nEffect of Underwear Materials on the Thermal Insulation of Barrier Protective Clothing  \nMagdalena Młynarczyk 1, *, Joanna Orysiak 1, Aleksandra Kopyt 1 and Szymon Ordysi ´nski 2  \nAcademic Editor: Antonio Caggiano  \nReceived: 3 December 2025  \nRevised: 22 December 2025  \nAccepted: 26 December 2025  \nPublished: 30 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 Laboratory of Thermal Load, The Department of Ergonomics, Central Institute for Labour Protection—National Research Institute, Czerniakowska St. 16, 00-701 Warsaw, Poland; [joanna.orysiak@ciop.pl](joanna.orysiak@ciop.pl) (J.O.); [alkop@ciop.pl](alkop@ciop.pl) (A.K.)  \n2 Laboratory of Working Conditions Research, The Department of Safety and Health Management, Central Institute for Labour Protection—National Research Institute, Czerniakowska St. 16, 00-701 Warsaw, Poland; [szord@ciop.pl](szord@ciop.pl)  \n* [Correspondence: m.mlynarczyk@ciop.pl](Correspondence: m.mlynarczyk@ciop.pl); Tel.: +48-22-623-32-76  \nAbstract  \nMedical personnel wearing barrier clothing protecting against infectious agents are at risk of heat stress resulting from limited heat exchange with the environment. The aim of the study was to assess the impact of changing underwear on the thermal parameters of protective clothing sets and on the expected safe working time. The study used a Newton thermal manikin to determine the thermal insulation and water vapor resistance of clothing sets consisting of three types of underwear (standard medical underwear and short and long thermal underwear) worn under two types of barrier suits. The obtained data were used to conduct physiological simulations in the Predicted Heat Strain (PHS) program, estimating the time it takes for core body temperature to rise to 38 ◦ C in conditions of 22 ◦ Cand 35 ◦ C. The results showed that replacing medical underwear with thermal underwear at 22 ◦ C extended safe working time by 24% . In hot conditions (35 ◦ C), the positive impact was smaller, extending working time by a maximum of 4% . Changing the inner layer is an effective method of improving comfort and safety in barrier clothing, especially in thermoneutral conditions.  \nKeywords: underwear; thermal comfort; barrier coverall; COVID-19; PPE  \n1. Introduction  \nThe heat load of medical workers is the result of three factors: environmental conditions (especially high temperature and high relative humidity), metabolic rate, also related to the work performed, and the protective clothing used.  \nEnvironmental conditions in many cases (e.g., operating room, patient room, staff rooms, sterilization room) are characterized by high temperatures. Examples collected by country and room type are included in Table 1.  \nTable 1. Mean values with standard deviation of temperature measured in selected hospital rooms indifferent countries.  \n\n| Place/Country | Range or Maximal Value of Air Temperature [ ◦ C] |\n| --- | --- |\n| patients’ room (Italy) [1] different wards at a hospital (Iran) [2] | 26–29 ◦ C\u003Cbr>29.9 ◦ C |\n\nTable 1. Cont.  \n\n| Place/Country | Range or Maximal Value of Air Temperature [ ◦ C] |\n| --- | --- |\n| dialysis storeroom at a hospital (Iran) [2] | 31.5 ◦ C |\n| nurse station (emergency hospitalization) at a hospital\u003Cbr>(Iran) [2] | 30 ◦ C |\n| patient rooms (Malaysia) [3] | 23.5 ◦ C |\n| visitors room (Malaysia) [3] | 23.2 ◦ C |\n| several departments at a hospital (Malaysia) [4] | 25.3–28.2 ◦ C |\n| patients’ room at a hospital (Thailand) [5] | 21.8–27.9 ◦ C |\n| visitors’ room at a hospital (Thailand) [5] | 22.0–27.1 ◦ C |\n| medical staff room at a hospital (Thailand) [5] | 24.1–25.6 ◦ C |\n| operating surgeon (Canada) [6] | 18.7–29.6 ◦ C |\n| patients’ room (Poland) [7] | 21.9–28.4 ◦ C |\n| nurse station at a hospital (UK) [8] | 27.7–29.3 ◦ C. |\n| patients’ room (multi-bad) at a hospital (UK)","cbCaijVwdZ2FJRsW","https://ap.wps.com/l/cbCaijVwdZ2FJRsW","pdf",3125835,"English","# Abstract\n# Keywords\n# 1. Introduction\n## Heat load factors\n## Environmental temperature examples\n## Metabolic rate and workload intensity\n## Barrier clothing and thermal parameters","[{\"question\":\"What was the aim of the study?\",\"answer\":\"To assess how changing underwear affects the thermal parameters of barrier protective clothing and the expected safe working time.\"},{\"question\":\"How were thermal insulation and water vapor resistance measured?\",\"answer\":\"Thermal insulation and water vapor resistance were determined using a Newton thermal manikin for clothing sets combining three underwear types with two barrier suit types.\"},{\"question\":\"How did underwear changes influence safe working time at 22°C and 35°C?\",\"answer\":\"At 22°C, replacing medical underwear with thermal underwear extended safe working time by 24%. At 35°C, the benefit was smaller, extending working time by up to 4%.\"}]","Effect of Underwear Materials on the Thermal Insulation of Barrier Protective Clothing | PDF",1790770804,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/f9e020ff419a0ac5684f31abc98f04e8.webp",983,1390,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/4728716ad9cc93503af2a2f31db504d9.webp",982,1388,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/d24d72f1b39744461f744776b8b34266.webp",981,1387,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/3ca2434f294e2176fb9a8c0c7ebaf443.webp",980,1385]