[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-460297-105":59,"doc-detail-460297-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","effect-of-two-wavelengths-of-diode-laser-on-the-efficacy-of-teeth-whitening-of-stained-teeth-using-three-different-teeth-whitening-agents-an-in-vitro-study","Effect of Two Wavelengths of Diode Laser on the Efficacy of Teeth Whitening of Stained Teeth Using Three Different Teeth Whitening Agents: An In Vitro Study","","Objective: Pilot in vitro study assesses and compares how two diode laser wavelengths (810 nm and 450 nm) activate three whitening agents—40% hydrogen peroxide (HP), 20% carbamide peroxide (CP), and 12% phthalimido-peroxy caproic acid (PAP)—by quantifying posttreatment color change (ΔE). Methods: Thirty extracted human teeth stained with standardized tea solution were allocated to agent-based groups and further treated with either 810 nm or 450 nm diode lasers. Spectrophotometric color evaluation occurred at baseline (T0), post-staining (T1), and post-whitening (T2). Results: All groups showed ΔE reduction after whitening, with 20% CP plus 450 nm achieving the greatest improvement (P\u003C0.05). Conclusion: A 450 nm diode laser combined with 20% CP yields the most effective teeth whitening outcome. Laser wavelength significantly affects activation efficacy.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/effect-of-two-wavelengths-of-diode-laser-on-the-efficacy-of-teeth-whitening-of-stained-teeth-using-three-different-teeth-whitening-agents-an-in-vitro-study/460297/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/effect-of-two-wavelengths-of-diode-laser-on-the-efficacy-of-teeth-whitening-of-stained-teeth-using-three-different-teeth-whitening-agents-an-in-vitro-study/460297.png","ImageObject",300,407,{"name":92,"@type":93},"kopisore","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-20","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":39},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Which diode laser wavelengths and whitening agents were compared in the study?","Question",{"text":112,"@type":113},"The study compared diode laser wavelengths of 810 nm and 450 nm, using three whitening agents: 40% hydrogen peroxide (HP), 20% carbamide peroxide (CP), and 12% PAP (phthalimido-peroxy caproic acid).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How was tooth staining and color change (ΔE) measured?",{"text":117,"@type":113},"Extracted non-carious human teeth were stained with a standardized tea solution, then baseline (T0), post-staining (T1), and post-whitening (T2) color were measured using a spectrophotometer. ΔE quantified the color change between time points.",{"name":119,"@type":110,"acceptedAnswer":120},"What combination showed the best whitening effect?",{"text":121,"@type":113},"The 20% CP group activated with the 450 nm diode laser showed the most significant improvement, with the highest ΔE reduction from T1 to T2 (P \u003C 0.05).","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},460297,1790758170,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":39,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":39,"preview_page_count":81,"preview_urls":143},962090880963,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Original Research  \nEffect of Two Wavelengths of Diode Laser on the Efficacy of Teeth Whitening of Stained Teeth Using Three Different Teeth Whitening Agents: An In Vitro Study  \nAnjana D S, Rakesh R. Rajan, Anju Varughese, Sapna C. Mudappa, Kaushik Haridas  \nDepartment of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India  \nSubmitted: 28‑Jul‑2025  \nRevised: 09‑Aug‑2025  \nAccepted: 19‑Aug‑2025  \nPublished: 17‑Dec‑2025  \nAbstract  \nObjective: This pilot study evaluates and compares the effectiveness of two diode laser wavelengths (810 nm and 450 nm) in activating three tooth whitening agents—40% hydrogen peroxide (HP), 20% carbamide peroxide (CP), and 12% phthalimido‑peroxy caproic acid (PAP), by analyzing the posttreatment color change (ΔE) . Methods: Thirty extracted human teeth were stained using a standardized tea solution and divided into three groups based on the whitening agent used. Each group was subdivided and treated with either 810 nm or 450 nm diode lasers. Color change was evaluated using a spectrophotometer at three stages: baseline (T0), post‑staining (T1), and post‑whitening (T2) . Results: All groups exhibited a decrease in ΔE post‑whitening. Group 2B (20% CP+450 nm laser) showed the most significant improvement, with the highest ΔE reduction from T1 to T2 (P \u003C 0.05) . Conclusion: 450 nm diode laser in combination with 20% CP provided the most effective teeth whitening result. Laser wavelength significantly influenced the activation efficacy of teeth whitening agents.  \nKeywords: Diode lasers, discoloration, extrinsic, spectrophotometer, teeth  \nwhitening   \nIntroduction  \nBoth internal and  \ndiscoloration.[1]  \nexternal factors can cause tooth Among the commonly used  \nteeth whitening agents, hydrogen peroxide (HP) and carbamide peroxide (CP) whitening agents are limited by instability, potential enamel erosion, reduced microhardness, and adverse effects like dentinal hypersensitivity and mucosal irritation with prolonged use. Recently, phthalimido‑peroxy caproic acid (PAP) has emerged as a non‑peroxide alternative to minimize sensitivity and soft tissue irritation.[2] FDA‑approved diode lasers (800–980 nm) are effective for whitening, with lower wavelengths targeting pigments and higher ones absorbed by water to reduce heat and penetration. With increase in interest in laser‑assisted teeth whitening, various laser systems, including KTP, argon, Er: YAG, and diode lasers (810 nm and 450 nm), are being explored to enhance the performance of both peroxide and non‑peroxide agents.[3] Therefore, the current study aimed to measure and compare the efficacy of two diode  \n\n| Access this article online |  |\n| --- | --- |\n| Quick Response Code:\u003Cbr>| Website: [https://journals.lww.com/jpbs](https://journals.lww.com/jpbs) |\n|  | DOI: 10.4103/jpbs.jpbs_1298_25 |\n\nlaser wavelengths (810 nm and 450 nm) in activating three teeth whitening agents, 40% HP, 20% CP, and 12% PAP by analyzing posttreatment color change (∆E) .  \nMethodology  \nAn in vitro pilot study was conducted after approval by the Institutional Ethics Committee of Amrita Institute of Medical Sciences, Kochi (ECASM‑AIMS‑2024‑078) . Thirty freshly extracted, non‑carious human incisors were sterilized and stored in distilled water for seven days. Baseline color (T0) was measured using a Vita Easyshade V spectrophotometer. CIE Lab* values were recorded, and then, the ΔE value (color change) was  \nAddress for correspondence: Dr. Rakesh R. Rajan, Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry,  \nAmrita Vishwa Vidyapeetham, Kochi - 682 041, Kerala, India.  \nE-mail: [drrakeshrajan@gmail.com](drrakeshrajan@gmail.com)  \nThis is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License (CC BY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be c","cbCailZdxRey21T4","https://ap.wps.com/l/cbCailZdxRey21T4","pdf",577694,"English","# Abstract\n# Introduction\n# Methodology","[{\"question\":\"Which diode laser wavelengths and whitening agents were compared in the study?\",\"answer\":\"The study compared diode laser wavelengths of 810 nm and 450 nm, using three whitening agents: 40% hydrogen peroxide (HP), 20% carbamide peroxide (CP), and 12% PAP (phthalimido-peroxy caproic acid).\"},{\"question\":\"How was tooth staining and color change (ΔE) measured?\",\"answer\":\"Extracted non-carious human teeth were stained with a standardized tea solution, then baseline (T0), post-staining (T1), and post-whitening (T2) color were measured using a spectrophotometer. ΔE quantified the color change between time points.\"},{\"question\":\"What combination showed the best whitening effect?\",\"answer\":\"The 20% CP group activated with the 450 nm diode laser showed the most significant improvement, with the highest ΔE reduction from T1 to T2 (P \\u003c 0.05).\"}]","Effect of Two Wavelengths of Diode Laser on the Efficacy of Teeth Whitening of Stained Teeth Using Three Different Teeth Whitening Agents: An In Vitro Study | PDF",[144,148,152],{"page_no":8,"url":145,"width":146,"height":147},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/fd72604a79a875ebbb1e5954c98143dd.webp",983,1272,{"page_no":14,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/2ee2d54be67369ff3a6c748d1df6646f.webp",982,1270,{"page_no":81,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/3aae275850ae3081d73d807724fa248c.webp",981,1269]