[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-383821-105":59,"doc-detail-383821-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","effect-of-topical-agents-on-skin-surface-dose-in-volumetric-modulated-arc-therapy-for-head-and-neck-cancer","Effect of topical agents on skin surface dose in volumetric modulated arc therapy for head and neck cancer","","Volumetric modulated arc therapy (VMAT) may show minimal clinical impact from increased skin surface dose caused by topical agents, yet the bolus effect remains a concern. This study examined three topical agents with different thicknesses (0.1, 0.5, and 2 mm) in VMAT for head and neck cancer, measuring surface doses in anterior static field and VMAT with and without a thermoplastic mask. No significant differences appeared among agents; increases depended on thickness and mask use, and dosimetric simulation suggested 2% increase under clinical standard thickness (0.02 mm), indicating nonsignificant effects in clinical conditions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/effect-of-topical-agents-on-skin-surface-dose-in-volumetric-modulated-arc-therapy-for-head-and-neck-cancer/383821/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/effect-of-topical-agents-on-skin-surface-dose-in-volumetric-modulated-arc-therapy-for-head-and-neck-cancer/383821.png","ImageObject",300,407,{"name":92,"@type":93},"Sophia Brooks","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-24","2026-09-24",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What was the purpose of this study on topical agents in VMAT?","Question",{"text":112,"@type":113},"To evaluate the bolus effect of topical agents on skin surface dose in VMAT for head and neck cancer, including how agent thickness and use of a thermoplastic mask affect measured increases.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How were the topical agents and thicknesses designed for the measurements?",{"text":117,"@type":113},"Three types of topical agents were prepared with thicknesses of 0.1, 0.5, and 2 mm, then surface doses were measured for both an anterior static field and VMAT with and without a thermoplastic mask.",{"name":119,"@type":110,"acceptedAnswer":120},"Did the study find significant differences in skin surface dose among the topical agents?",{"text":121,"@type":113},"No significant differences were observed among the three topical agents, although the magnitude of dose increase varied with thickness and whether the thermoplastic mask was used.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},383821,1790576575,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":19,"preview_urls":145},962084925636,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Journal of Radiation Research, Vol. 64, No. 4, 2023, pp. 644–650 [https://doi.org/10.1093/jrr/rrad035](https://doi.org/10.1093/jrr/rrad035)  \nAdvance Access Publication: 6 June 2023  \nEffect of topical agents on skin surface dose in volumetric modulated arc therapy for head and  \nneck cancer  \nHikari Ueda 1, Yoshihiro Ueda 1, *, Toshiki Ikawa 1, Shingo Ohira 1, Masayoshi Miyazaki 1, Kazumi Enomoto2, Kayo Sakai2 and Koji Konishi 1  \n1Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69, Otemae, Chuo-ku, Osaka 537-8567, Japan  \n2Nursing Department, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 537-8567 Osaka, Japan  \n*Corresponding author. Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69, Otemae, Chuo-ku, Osaka 537-8567, Japan.  \n[Email: yoshihiro.ueda@oici.jp](Email: yoshihiro.ueda@oici.jp)  \nPresentation at a Conference: A portion of this study was presented at the 34th Annual Meeting of the Japanese Society for Radiotherapy held in November 2021.  \n(Received 12 December 2022; revised 27 February 2023; editorial decision 6 April 2023)  \nABSTRACT  \nIn volumetric modulated arc therapy (VMAT), the effect of an increase in skin surface dose due to topical agents might be negligible. We investigated the bolus effects of three types of topical agents in VMAT for head and neck cancer (HNC). Topical agents of different thicknesses (0.1, 0.5 and 2 mm) were prepared. When each topical agent was set, the surface doses were measured for the anterior static field and VMAT, with and without a thermoplastic mask. No significant differences were observed among the three topical agents. For topical agent thicknesses of 0.1, 0.5 and 2 mm, the increases in surface dose for the anterior static field without the thermoplastic mask were 7–9, 30–31 and 81–84%, respectively. With the thermoplastic mask, the corresponding increases were 5, 12–15 and 41– 43%, respectively. The increases in surface dose for VMAT without the thermoplastic mask were 5–8, 16–19 and 36–39%, respectively, and those with the thermoplastic mask were 4, 7–10 and 15–19%, respectively. The rate of increase in surface dose with the thermoplastic mask was smaller than that without the thermoplastic mask. The increase in surface dose with topical agents of clinical standard thickness (0.02 mm) was estimated to be 2% with the thermoplastic mask. The increase in surface dose with topical agents in dosimetric simulation, compared with control situation, is not significant in clinical conditions for HNC patients.  \nKeywords: volumetric modulated arc therapy; topical agent; radiation dermatitis; skin surface dose  \nINTRODUCTION  \nRadiation dermatitis is a common side effect of radiotherapy for head and neck cancer (HNC). Approximately 90% of patients receiving radiotherapy for HNC develop radiation dermatitis. It can become severe in ∼25% of these patients [1]. The severity of radiation dermatitis is closely related to the radiation dose received by the skin [2, 3]. Among patients with radiation dermatitis, mild patients showslight redness and itching. Severe patients experience severe pain and infections resulting from severe desquamation [4–6]. Radiation dermatitis can impair patients’ quality of life and even cause treatment discontinuation [7, 8].  \nTo prevent exacerbation of radiation dermatitis, it is important to take care of the skin during radiotherapy by using topical agents such as ointments, creamsand lotions[5, 8, 9]. However, Baumannetal. conducted anonymous online surveys on a non-profit educational website  \nand reported that 91% of the respondent medical staff advise patients to avoid applying topical agents just before or within a few hours of radiotherapy [ 10]. The medical staff advises against applying topical agents because they are worried that topical agents may act as a bolus, which could increase the skin surface dose and accelerate skin damage. This advice may make patients hesitate ","cbCaigXnKUfpjHpz","https://ap.wps.com/l/cbCaigXnKUfpjHpz","pdf",924840,"English","# Abstract\n# Introduction","[{\"question\":\"What was the purpose of this study on topical agents in VMAT?\",\"answer\":\"To evaluate the bolus effect of topical agents on skin surface dose in VMAT for head and neck cancer, including how agent thickness and use of a thermoplastic mask affect measured increases.\"},{\"question\":\"How were the topical agents and thicknesses designed for the measurements?\",\"answer\":\"Three types of topical agents were prepared with thicknesses of 0.1, 0.5, and 2 mm, then surface doses were measured for both an anterior static field and VMAT with and without a thermoplastic mask.\"},{\"question\":\"Did the study find significant differences in skin surface dose among the topical agents?\",\"answer\":\"No significant differences were observed among the three topical agents, although the magnitude of dose increase varied with thickness and whether the thermoplastic mask was used.\"}]","Effect of topical agents on skin surface dose in volumetric modulated arc therapy for head and neck cancer | PDF",1790259454,18,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/aa0aa3220f4d57f372b2844c9c485aea.webp",983,1269,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/62a8c7405754a0ee57a3fd379d7eb9ae.webp",982,1268,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/d1da5d5a489fe841f0cfc78d206cf611.webp",981,1266,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/ba313bfc521b950ca1202cbd1a771347.webp",980,1265]