[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-460817-105":59,"doc-detail-460817-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","effect-of-tibial-tray-backside-design-on-stress-transfer-and-micromotion-in-uncemented-posterior-stabilized-tka-finite-element-study","Effect of Tibial Tray Backside Design on Stress Transfer and Micromotion in Uncemented Posterior-Stabilized TKA - finite element study","","This finite element study investigates how different tibial tray backside designs affect biomechanical fixation in uncemented posterior-stabilized total knee arthroplasty (PS-TKA). Motivated by higher lifetime and functional demands in younger, active patients, the work focuses on tibial implant–bone interface micromotion and stress transfer, factors linked to early tibial loosening. Three designs are modeled and compared under knee loading using von Mises stress and micromotion metrics.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/effect-of-tibial-tray-backside-design-on-stress-transfer-and-micromotion-in-uncemented-posterior-stabilized-tka-finite-element-study/460817/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/effect-of-tibial-tray-backside-design-on-stress-transfer-and-micromotion-in-uncemented-posterior-stabilized-tka-finite-element-study/460817.png","ImageObject",300,407,{"name":92,"@type":93},"Jake","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",15,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What problem does the study address in uncemented posterior-stabilized TKA?","Question",{"text":113,"@type":114},"Early tibial loosening risk is influenced by interface micromotion and stress transfer at the tibial implant–bone interface, especially under gait and deep-flexion activities.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How were the tibial tray backside designs evaluated?",{"text":118,"@type":114},"Finite element and micromotion models quantified tibial von Mises stress and interface micromotion under knee loading conditions.",{"name":120,"@type":111,"acceptedAnswer":121},"Which design performed best during squatting and why?",{"text":122,"@type":114},"The cylindrical stem with double serrated keel showed the highest proximal tibial stress and the lowest maximum micromotion, yielding the largest area suitable for bone ingrowth.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},460817,1790764170,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":52,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},962084928904,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","DOI: 10.1002/jeo2.70608  \nORIGINAL PA PER  \nEﬀect of tibial tray backside design on stress transfer and micromotion in uncemented posterior‐stabilized TKA: A ﬁnite element study  \nZhenxian Chen1 | Zhangwen Ma2  | Bo Liang 1  | Jianian Han1 | Jing Zhang 1 | Yinghu Peng3 | Zhongmin Jin4,5  \n1School of Construction Machinery, Chang' an University, Xi'an, Shaanxi, China 2Department of Bone Surgery, Aﬃliated Hospital of Yan’ an University, Yan'an,  \nShaanxi, China  \n3CAS Key Laboratory of Human‐Machine Intelligence‐Synergy Systems, Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences, Shenzhen, China 4Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK 5Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, Sichuan, China  \nCorrespondence  \nZhangwen Ma, Department of Bone Surgery, Aﬃliated Hospital of Yan’ an University, Yan'an, Shaanxi, China. [Email:](Email: mazhangwen2008@126.com)[ mazhangwen2008@126.com](Email: mazhangwen2008@126.com)  \nFunding information  \nNational Natural Science Foundation of China, Grant/Award Number: Grant number 12202074; Fundamental Research Funds for the Central Universities, CHD,  \nGrant/Award Number: Grant number 300102254205  \nAbstract  \nPurpose: The uncemented posterior‐stabilized total knee arthroplasty (PS‐TKA) gained increasing acceptance as younger and active patients have higher requirements for the lifespan and functionality of prostheses, because their frequent gait and deep‐ﬂexion activities may amplify tibialimplant–bone interface micromotion and increase the risk of early tibial loosening. The purpose of this study is to evaluate the biomechanical ﬁxation eﬀects of three diﬀerent tibial tray backside designs, with the aim of informing surgeons in selecting the most appropriate ﬁxation strategy for uncemented PS‐TKA.  \nMethods: The ﬁnite element and micromotion models were developed to quantify the tibial von Mises stress and interface micromotion under the knee loading conditions. The eﬀects of three common tibial tray backside designs, including a cylindrical stem with a triple ﬂat keel (CS‐TFK), a tapered stem with a double ﬂat keel (TS‐DFK) and a cylindrical stem with a double serrated keel (CS‐DSK), on stress transfer and interface micromotion were compared.  \nResults: During walking, all designs exhibited similar stress and micromotion patterns, with minimal risk for prostheses instability. During squatting, the cylindrical stem with double serrated keel design exhibited the highest proximal tibial stress (124.03 MPa) and the lowest maximum micromotion (361 .91 µm), resulting in the largest area suitable for bone ingrowth (42 .53%) . In contrast, the tapered stem with double ﬂat keel design had the lowest stress (90.70 MPa), and its area at risk for poor osseointegration (micromotion >150 µm) increased by 44.70% compared with the cylindrical stem with double serrates keel design.  \nDiscussion: The tibial tray backside design inﬂuenced its primary ﬁxation. Among the evaluated designs, the CS‐DSK balanced stress transfer and interface micromotion, suggesting it may be favored for uncemented PS‐ TKA in younger, active patients to lower the likelihood of early tibial aseptic loosening. CS‐DSK favored early ingrowth but produced higher local  \nAbbreviations: 3D, three‐dimensional; CoCrMo, cobalt‐chromium‐molybdenum; CT, computed tomography; FE, ﬁnite element; FEA, ﬁnite element analysis; KOA, knee osteoarthritis; PCSA, physiological cross‐sectional area; PS, posterior‐stabilized; TKA, total knee arthroplasty; UHMWPE, ultra‐high molecular weight polyethylene.  \nThis is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.  \n© 2026 The Author(s) . Journal of Experimental Orthopaedics published by John Wiley & Sons Ltd on behal","cbCait6NYgtPAisl","https://ap.wps.com/l/cbCait6NYgtPAisl","pdf",2321548,"English","# Abstract\n## Purpose\n## Methods\n## Results\n## Discussion\n# Introduction","[{\"question\":\"What problem does the study address in uncemented posterior-stabilized TKA?\",\"answer\":\"Early tibial loosening risk is influenced by interface micromotion and stress transfer at the tibial implant–bone interface, especially under gait and deep-flexion activities.\"},{\"question\":\"How were the tibial tray backside designs evaluated?\",\"answer\":\"Finite element and micromotion models quantified tibial von Mises stress and interface micromotion under knee loading conditions.\"},{\"question\":\"Which design performed best during squatting and why?\",\"answer\":\"The cylindrical stem with double serrated keel showed the highest proximal tibial stress and the lowest maximum micromotion, yielding the largest area suitable for bone ingrowth.\"}]","Effect of Tibial Tray Backside Design on Stress Transfer and Micromotion in Uncemented Posterior-Stabilized TKA - finite element study | PDF",1790759696,25,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/75f4d1dfa1c1d1d0093191f902695243.webp",983,1291,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/fb63e4016a37816fb6daa97c2910b4f7.webp",982,1290,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/add379c915a61c02522173b4b45f09bd.webp",981,1289,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ccc37069ef2409cbd516b8b32f833716.webp",980,1287]