[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-513243-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-513243-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","effect-of-temperature-on-the-electrical-resistance-and-voltage-departures-errors-of-glass-electrodes-upon-the-hygroscopicity-of-glass","Effect of Temperature on the Electrical Resistance and Voltage Departures (Errors) of Glass Electrodes - Upon the Hygroscopicity of Glass","","Investigation examines how temperature influences the electrical resistance and pH response of glass electrodes made from Pyrex 7740, commercial soft-glass tubing, and Corning 015, spanning low to high hygroscopicity. Results show electrical resistance is generally not the controlling factor behind voltage departures from theoretical behavior, including failures to follow Nernst equation expectations. Pyrex electrodes can show little or no significant pH response even at resistance as low as 12 megohms. Corning 015 produces voltage departures that cannot be explained by electrode resistance.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/effect-of-temperature-on-the-electrical-resistance-and-voltage-departures-errors-of-glass-electrodes-upon-the-hygroscopicity-of-glass/513243/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/effect-of-temperature-on-the-electrical-resistance-and-voltage-departures-errors-of-glass-electrodes-upon-the-hygroscopicity-of-glass/513243.png","ImageObject",300,407,{"name":42,"@type":43},"AfterMidnight","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-16","2026-10-06",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",10,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the main purpose of the study?","Question",{"text":63,"@type":64},"To determine how hygroscopicity of glass and electrical resistance of the glass membrane affect whether glass electrodes can act as indicators of hydrogen-ion activity in aqueous solutions across a temperature range from 20°C to near boiling.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How were voltage performance changes measured?",{"text":68,"@type":64},"The voltage change was observed when a cell using the experimental electrode and a reference electrode was transferred from a buffer at pH 4.1 to a buffer at pH 8.2, with the reference electrode calibrated for elevated temperatures.",{"name":70,"@type":61,"acceptedAnswer":71},"What do the results indicate about the role of electrical resistance?",{"text":72,"@type":64},"Electrical resistance is not the determinant in most cases of voltage departures, and poor pH response in many glasses is not due to high resistance or lack of sensitivity of the measuring electrometers.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},513243,1791436131,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":55,"slug":125},"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":102,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":144,"preview_page_count":33,"preview_urls":145},962090896061,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","# Effect of Temperature on the Electrical Resistance andVoltage Departures(Errors)of Glass Electrodes,andUpon the Hygroscopicity of Glass\n\nDonald Hubbard  \nThe effect of temperature upon the electrical resistance and pH response has beenstudied on electrodes prepared from three types of glasses:Pyrex 7740,commercial soft-glass tubing,and Corning,015;glasses of low,intermediate,and high hygroscopicity,re-spectively.The results show that electrical resistance is not the determinant in mostcases of voltage departure from the theoretical,and in the inherent failure of many glassesto act as satisfactory indicators of hydrogen-ion activity of aqueous solutions.For example,the electrodes prepared from Pyrex glass gave no significant pH response even when theresistance was as low as 12 megohms.The results of electrodes from glasses of intermediatehygroscopicity gave a pseudo-correspondence of pH response with resistance,whereaselectrodes of Corning 015 gave voltage departures that could in no way be attributed to theelectrical resistance of the electrode.  \n## 1.Introduction\n\nConsiderable confusion exists in the general con-cept as to what part the electrical resistance of aglass electrode plays in its voltage response to hydro-gen-ion activity of aqueous solutions,the voltagedepartures(errors)that appear at high alkalinitiesand in the\"superacid\"region,and particularly in thefailure of electrodes from many glasses to followthe simple dictates of the Nernst equation,△E=  \n0.000198T△pH.For example,the difference inperformance shown between electrodes from Pyrex7740 and a satisfactory pH-responsive glass(fig.1)is presumed to be related somehow to a difference inresistance of the glass membranes forming the effec-tive portion of the electrode.With the electrometertubes available requiring grid currents of only 10-12to 10-15amp,a glass electrode having a resistance asgreat as 1,000 megohms would exhibit an IR drop(error)ranging from 10-³to 10-⁶v[1,pages 47 and89 to 92].Such errors are small,and for mostpractical pH measurements can be disregarded.Itis obvious that glass electrodes exhibiting largevoltage departures,pH errors,but having resistancesless than 1,000 megohms,are failing to show fullpH response not because of their high electricalresistance nor because of a lack of sensitivity of theavailable indicating electrometers.  \nThe present investigation was undertaken to as-certain what individual parts the hygroscopicity(water sorption)of the glass and the electrical resist-ance of the glass membrane play in the over-allpicture of the ability,or lack of ability,of electrodesfrom various glasses to act as indicators of hydrogen-ion activity of aqueous solutions over the temperaturerange 20°℃ to near the boiling point of water.  \n## 2.Experimental Procedures\n\nThe bygroscopicity values were obtained in theapparatus described in previous publications [2].  \nThe experiments at elevated temperatures werecarried out by immersing the humidity chamber in athermostated water bath.Although no mechanicaldifficulties were encountered,this procedure forobtaining hygroscopicity was not entirely satisfac-tory,because of excessive condensation on the wallsof the chamber at the elevated temperatures for thehigh humidity(approximately 98 percent)requiredfor the experiments.However,the results appearedto be qualitatively acceptable.The hygroscopicityvalues reported are those obtained for 1-hour ex-posures.  \nThe voltage performance of any experimentalelectrode was determined by the voltage change thatappeared when the cell consisting of the experimentalelectrode and a reference electrode was transferredfrom a buffer solution at pH4.1 to a buffer at pH8.2.The reference electrode employed was either a hydro-gen electrode or a glass electrode calibrated at theelevated temperatures.Thus if the experimentalelectrode gave full pH response,no change in voltageappeared in the two buffers at any temperatures.Typical examples of the data obtained by this pro-cedure","cbCaiv14g1I2RIrg","https://ap.wps.com/l/cbCaiv14g1I2RIrg","pdf",7291447,"English","# 1. Introduction\n# 2. Experimental Procedures","[{\"question\":\"What is the main purpose of the study?\",\"answer\":\"To determine how hygroscopicity of glass and electrical resistance of the glass membrane affect whether glass electrodes can act as indicators of hydrogen-ion activity in aqueous solutions across a temperature range from 20°C to near boiling.\"},{\"question\":\"How were voltage performance changes measured?\",\"answer\":\"The voltage change was observed when a cell using the experimental electrode and a reference electrode was transferred from a buffer at pH 4.1 to a buffer at pH 8.2, with the reference electrode calibrated for elevated temperatures.\"},{\"question\":\"What do the results indicate about the role of electrical resistance?\",\"answer\":\"Electrical resistance is not the determinant in most cases of voltage departures, and poor pH response in many glasses is not due to high resistance or lack of sensitivity of the measuring electrometers.\"}]","Effect of Temperature on the Electrical Resistance and Voltage Departures (Errors) of Glass Electrodes - Upon the Hygroscopicity of Glass | PDF",1791282219,15,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c0e124f018a23545458bafc4e793f8f7.webp",983,1330,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/7b1886a00143f0ff247d3ddbed481c6b.webp",982,1328,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/1f2d25374a28afb9cecc7fe7e7ce60e6.webp",981,1326,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/2784835fb71de01a77160166f6a2fe8a.webp",980,1325]