[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-355710-105":59,"doc-detail-355710-en":135},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":128,"head_meta":130,"extra_data":132,"updated_unix":134},105,"en","effect-of-multi-leaf-collimator-angle-optimization-on-the-planning-parameters-in-intensity-modulated-radiotherapy-for-thoracic-tumors","Effect of Multi-Leaf Collimator Angle Optimization on the Planning Parameters in Intensity-Modulated Radiotherapy for Thoracic Tumors","","Investigates how multi-leaf collimator (MLC) angle optimization affects planning parameters in intensity-modulated radiotherapy (IMRT) for thoracic tumors. A retrospective cohort of 42 patients with esophageal or lung cancer received two Eclipse-generated IMRT plans: MLC angle at 0° to trigger automatic field splitting versus an adjusted angle limiting X-jaw aperture below 13.8 cm to avoid splitting. Compared target homogeneity/conformity, OAR doses, monitor units, and treatment time, with dose verification performed. Results show similar target coverage and dose distributions, while adjusted MLC angles significantly reduce MUs and treatment time without compromising safety. Concludes the approach can improve efficiency while maintaining OAR protection.",{"@graph":69,"@context":127},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/effect-of-multi-leaf-collimator-angle-optimization-on-the-planning-parameters-in-intensity-modulated-radiotherapy-for-thoracic-tumors/355710/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/effect-of-multi-leaf-collimator-angle-optimization-on-the-planning-parameters-in-intensity-modulated-radiotherapy-for-thoracic-tumors/355710.png","ImageObject",300,407,{"name":92,"@type":93},"Nguyễn Văn Học","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-03","2026-09-22",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119,123],{"name":110,"@type":111,"acceptedAnswer":112},"What was the goal of optimizing the multi-leaf collimator (MLC) angle in this study?","Question",{"text":113,"@type":114},"To determine how MLC angle optimization changes planning parameters in IMRT for thoracic tumors, especially regarding target coverage, organ-at-risk (OAR) doses, and efficiency metrics like monitor units and treatment time.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How were the two IMRT plans designed for each patient?",{"text":118,"@type":114},"In Eclipse, one plan set the MLC angle to 0° to trigger automatic field splitting due to excessive X-jaw aperture, and the other adjusted the MLC angle to keep the X-jaw aperture below 13.8 cm to avoid field splitting.",{"name":120,"@type":111,"acceptedAnswer":121},"What outcomes differed most between the MLC 0° plan and the adjusted-angle plan?",{"text":122,"@type":114},"The adjusted-angle plans significantly reduced the number of monitor units and treatment time for both esophageal and lung cancer cases, while maintaining similar target dose distributions and meeting clinical requirements.",{"name":124,"@type":111,"acceptedAnswer":125},"Did dose verification show differences between the two planning approaches?",{"text":126,"@type":114},"Dose verification reported no significant difference between the two methods, supporting that the adjusted-angle strategy maintained delivery accuracy.","https://schema.org",{"og:url":83,"og:type":129,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":131,"canonical":83},"index,follow",{"doc_id":133,"site_id":62},355710,1790248213,{"code":4,"msg":5,"data":136},{"doc_id":133,"user_id":137,"nickname":92,"user_avatar":138,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":139,"file_id":140,"file_url":141,"file_type":142,"file_size":143,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":105,"language":144,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":145,"faqs":146,"seo_title":147,"seo_description":67,"update_tm":148,"read_time":41,"preview_page_count":19,"preview_urls":149},1374402739827,"https://ap-avatar.wpscdn.com/avatar/14000c97e7351f1a627?x-image-process=image/resize,m_fixed,w_180,h_180&k=1787885694763230660","Effect of Multi-Leaf Collimator Angle Optimization on the Planning Parameters in Intensity-Modulated Radiotherapy for Thoracic Tumors  \nTechnology in Cancer Research & Treatment Volume 25: 1–12 © The Author(s) 2026 Article reuse guidelines:  \n[sagepub.com/journals-permissions](sagepub.com/journals-permissions)  \n[DOI: 10.1177/15330338261452644](DOI: 10.1177/15330338261452644)  \n[journals.sagepub.com/home/tct](journals.sagepub.com/home/tct)  \nChun-Yan Deng, MS1,*, Jia-Huan Cai, MS1,*, Ji-Yong Zhang, MS1, and Jia-Yang Lu, MS1   \nAbstract  \nIntroduction: To investigate the effect of multi-leaf collimator (MLC) angle optimization on the planning parameters in intensity-modulated radiotherapy (IMRT) for thoracic tumors. Methods: Forty-two patients (21 esophageal cancer, 21 lung cancer) were retrospectively enrolled. For each patient, two IMRT plans were designed in Eclipse treatment planning system: one with the MLC angle set to 0°, which triggered automatic field splitting due to excessive X-jaw aperture; the other with the MLC angle adjusted to keep the X-jaw aperture below 13.8 cm, thereby avoiding field splitting. The homogeneity index (HI) and conformity index (CI) of target volume, doses of organs at risk (OARs), monitor units (MUs) and treatment time were compared. Dose verification was performed. Results: For both esophageal and lung cancer patients, the two groups of plans met the clinical requirements and the dose distribution of target volume was similar. Compared with the plan of the MLCat 0°, the number of MUs and the treatment time were significantly reduced by adjusting the MLC angle to avoid automatic field splitting by the planning system. The average number of MUs in esophageal cancer and lung cancer patients was reduced from 1015.7 ± 162.8 and 1122.0 ± 315.3 to 853.3 ± 113.0 and 886.5 ± 264.8, respectively, and the average treatment time was shortened from 1.6 ± 0.3 min and 1.8 ± 0.6 minto 1.4 ± 0.2 min and 1.5 ± 0.5 min, respectively. The Dmean, V5Gy and V10Gy of the lung in patients with esophageal cancer and the Dmean, V10Gy and V20Gy of the lung in patients with lung cancer were significantly reduced (P \u003C 0.05) . Dose verification showed no significant difference between the two methods. Conclusions: For thoracic tumors with a large transverse range, the method of adjusting the MLC angle to prevent automatic field splitting may effectively reduce MUs and treatment time while maintaining target coverage and OAR safety.  \nKeywords  \nmulti-leaf collimator (MLC), thoracic tumors, intensity-modulated radiotherapy (IMRT), monitor unit (MU), treatment time Received: 10 December 2025; Revised: 15 April 2026; Accepted: 27 April 2026  \nIntroduction  \nLung cancer and esophageal cancer are two kinds of cancers with high incidence worldwide, 1 and they are very common malignant thoracic tumors in China, with high morbidity and mortality.2,3 Concurrent chemoradiotherapy is a commonly  \n1Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, China  \n*These authors contributed equally to this work.  \nCorresponding author:  \nJia-Yang Lu, MS, Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, No.7, Raoping Road, Shantou, Guangdong, 515000, China.  \nEmail: [lujam@163.com](lujam@163.com)  \nCreative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons  \nAttribution-NonCommercial 4.0 License ([https://creativecommons.org/licenses/by-nc/4.0/](https://creativecommons.org/licenses/by-nc/4.0/)) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages ([https://us.sagepub.com/en-us/nam/open-access-at-sage](https://us.sagepub.com/en-us/nam/open-access-at-sage)).  \nused treatment, especially for patients with inoperable advanced tumors.4-7 At present, in the radiotherapy plan des","cbCaifnkHDGgZzOZ","https://ap.wps.com/l/cbCaifnkHDGgZzOZ","pdf",3342698,"English","# Abstract\n# Introduction\n## Thoracic radiotherapy context and challenges\n## IMRT planning strategies for large targets\n# Methods and comparative plan design\n# Results\n# Conclusions","[{\"question\":\"What was the goal of optimizing the multi-leaf collimator (MLC) angle in this study?\",\"answer\":\"To determine how MLC angle optimization changes planning parameters in IMRT for thoracic tumors, especially regarding target coverage, organ-at-risk (OAR) doses, and efficiency metrics like monitor units and treatment time.\"},{\"question\":\"How were the two IMRT plans designed for each patient?\",\"answer\":\"In Eclipse, one plan set the MLC angle to 0° to trigger automatic field splitting due to excessive X-jaw aperture, and the other adjusted the MLC angle to keep the X-jaw aperture below 13.8 cm to avoid field splitting.\"},{\"question\":\"What outcomes differed most between the MLC 0° plan and the adjusted-angle plan?\",\"answer\":\"The adjusted-angle plans significantly reduced the number of monitor units and treatment time for both esophageal and lung cancer cases, while maintaining similar target dose distributions and meeting clinical requirements.\"},{\"question\":\"Did dose verification show differences between the two planning approaches?\",\"answer\":\"Dose verification reported no significant difference between the two methods, supporting that the adjusted-angle strategy maintained delivery accuracy.\"}]","Effect of Multi-Leaf Collimator Angle Optimization on the Planning Parameters in Intensity-Modulated Radiotherapy for Thoracic Tumors | PDF",1790120603,[150,154,158,162],{"page_no":8,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/290f4e9814c6d069cfa8ec8f63f00b91.webp",983,1310,{"page_no":14,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/eddb703b3da8610e83007f4d0b9c392e.webp",982,1309,{"page_no":81,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/5fb3ccb7a6e88ee897f5e82009056363.webp",981,1308,{"page_no":19,"url":163,"width":164,"height":165},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/ed4104d5afd6dba7b770b816b9a83402.webp",980,1306]