[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-460209-105":59,"doc-detail-460209-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","effect-of-laser-microtextured-collar-implants-on-soft-tissue-integration-and-crestal-bone-level","Effect of Laser Microtextured Collar Implants on Soft Tissue Integration and Crestal Bone Level","","Laser microtextured collar implants are evaluated for improving peri-implant soft tissue attachment and maintaining crestal bone levels to support long-term dental implant success. A randomized controlled clinical study recruited 40 systemically healthy patients needing single posterior mandibular implants, assigned into laser microtextured collar implants (n=20) and machined collar implants (n=20). Outcomes included probing depth, bleeding on probing, peri-implant mucosal thickness, and standardized digital radiographic crestal bone level changes assessed at baseline, 6 months, and 12 months. Results showed lower probing depth, reduced bleeding sites, and less crestal bone loss at 12 months with laser microtexturing.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/effect-of-laser-microtextured-collar-implants-on-soft-tissue-integration-and-crestal-bone-level/460209/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/effect-of-laser-microtextured-collar-implants-on-soft-tissue-integration-and-crestal-bone-level/460209.png","ImageObject",300,407,{"name":92,"@type":93},"Rainbow Cat","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":39},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What was the primary comparison between the two implant types?","Question",{"text":112,"@type":113},"The study compared laser microtextured collar implants with conventional machined collar implants regarding peri-implant soft tissue behavior and changes in crestal bone level.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which clinical parameters were evaluated during follow-up?",{"text":117,"@type":113},"Probing depth (PD), bleeding on probing (BOP), and peri-implant mucosal thickness were assessed at baseline, 6 months, and 12 months.",{"name":119,"@type":110,"acceptedAnswer":120},"What were the key findings at 12 months?",{"text":121,"@type":113},"At 12 months, the laser microtextured group showed significantly lower mean probing depth, fewer bleeding sites, and reduced crestal bone loss compared with the machined collar group.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},460209,1791153874,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":39,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":39,"preview_page_count":81,"preview_urls":144},962090769181,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Original Article  \nEffect of Laser Microtextured Collar Implants on Soft Tissue Integration and Crestal Bone Level  \nTanmay Srivastava1, Shruti Sinha1, Shivangi Pandey1, Anil Kumar Rodda2, Pratik Prakash Bumb3, Mrunal Dave4  \n1Department of Oral Medicine and Radiology, Saraswati Dental College and Hospital, Lucknow, Uttar Pradesh, India, 2Department of Periodonticsand Implantology, Government Dental College and Hospital, Hyderabad, Telangana, India, 3Department of Prosthodontics and Crown and Bridge, Teerthanker Mahaveer Dental College and Research Centre, Moradabad, Uttar Pradesh, India, 4Dentist Bethlehem Smile Design in Bethlehem, Pennsylvania, USA  \nSubmitted: 07‑Aug‑2025  \nRevised: 11‑Aug‑2025  \nAccepted: 19‑Aug‑2025  \nPublished: 17‑Dec‑2025  \nAbstract  \nBackground: The long-term success of dental implants is strongly influenced by peri‑implant soft tissue attachment and maintenance of crestal bone. Laser microtextured collar implants are designed to enhance epithelial and connective tissue adhesion, potentially improving biological seal, and reducing marginal bone loss. Materials and methods: A total of 40 patients requiring single posterior mandibular implants were recruited and randomly allocated into two groups (n = 20 each): Group A (laser microtextured collar implants) and Group B (machined collar implants) . Clinical parameters such as probing depth (PD), bleeding on probing (BOP), and peri‑implant mucosal thickness were assessed at baseline, 6 months, and 12 months. Radiographic assessment of crestal bone level changes was performed using standardized digital periapical radiographs. Data were analyzed using independent t‑tests and repeated measures ANOVA (α = 0.05) . Results: At 12 months, Group A showed significantly lower mean PD (2.1 ± 0.3 mm) compared to Group B (2.8 ± 0.4 mm, P \u003C 0.001) . BOP was observed in 10% of sites in Group A and 35% in Group B (P = 0.04) . The mean crestal bone loss in Group A was 0.39 ± 0.11 mm, significantly lower than 0.74 ± 0.14 mm in Group B (P \u003C 0.001) . Conclusion: Laser microtextured collar implants demonstrated superior soft tissue integration and reduced crestal bone loss compared to conventional implants, suggesting their potential benefit in enhancing peri‑implant tissue stability and implant longevity.  \nKeywords: Crestal bone loss, dental implants, laser microtextured collar, peri‑implant health, soft tissue integration   \nIntroduction  \nThe preservation of peri‑implant tissues is a critical  \nfactor in the long‑term success of dental implants.[1] While osseointegration ensures the mechanical stability of implants, the health and stability of surrounding soft and hard tissues are essential for preventing complications such as peri‑implantitis and marginal bone loss.[2,3]  \nThe design of the implant collar, particularly its surface characteristics, plays a pivotal role in determining the quality of soft tissue attachment and crestal bone response.[4] Traditional machined collars often present smooth surfaces that may limit soft tissue adhesion, potentially allowing apical migration of the junctional epithelium and crestal bone resorption.[5]  \n\n| Access this article online |  |\n| --- | --- |\n| Quick Response Code:\u003Cbr>| Website: [https://journals.lww.com/jpbs](https://journals.lww.com/jpbs) |\n|  | DOI: 10.4103/jpbs.jpbs_1412_25 |\n\nLaser microtexturing technology has emerged as a novel approach to modify the transmucosal collar of implants. By creating microgrooves of controlled depth and width, this surface is engineered to encourage perpendicular collagen fiber attachment and stable epithelial adhesion.[6,7] These histological features are hypothesized to form a more effective biological seal, reducing bacterial infiltration and inflammatory damage to the underlying bone.  \nSeveral animal and preliminary clinical studies suggest that laser microtextured collars may enhance soft  \n\n| Address for correspondence: Dr. Tanmay Srivastava, Department of Oral Medicine and Radiolog","cbCaimdUw2ee0dqA","https://ap.wps.com/l/cbCaimdUw2ee0dqA","pdf",564456,"English","# Abstract\n# Introduction\n## Peri-implant tissue preservation and implant collar surface design\n# Materials and Methods\n## Study design and participants\n## Group allocation\n## Inclusion criteria\n## Exclusion criteria\n# Results\n# Conclusion","[{\"question\":\"What was the primary comparison between the two implant types?\",\"answer\":\"The study compared laser microtextured collar implants with conventional machined collar implants regarding peri-implant soft tissue behavior and changes in crestal bone level.\"},{\"question\":\"Which clinical parameters were evaluated during follow-up?\",\"answer\":\"Probing depth (PD), bleeding on probing (BOP), and peri-implant mucosal thickness were assessed at baseline, 6 months, and 12 months.\"},{\"question\":\"What were the key findings at 12 months?\",\"answer\":\"At 12 months, the laser microtextured group showed significantly lower mean probing depth, fewer bleeding sites, and reduced crestal bone loss compared with the machined collar group.\"}]","Effect of Laser Microtextured Collar Implants on Soft Tissue Integration and Crestal Bone Level | PDF",1790758021,[145,149,153],{"page_no":8,"url":146,"width":147,"height":148},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/e9ceb9202674f48a1646ec2a3c680033.webp",983,1272,{"page_no":14,"url":150,"width":151,"height":152},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/43ce51df24b74c549f041df80643bb69.webp",982,1270,{"page_no":81,"url":154,"width":155,"height":156},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/be82706df0532dc2d3b799060f434193.webp",981,1269]