[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-457775-105":59,"doc-detail-457775-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","effect-of-anodization-on-metal-ceramic-bond-strength-of-titanium-manufactured-by-selective-laser-melting-an-in-vitro-study","Effect of anodization on metal-ceramic bond strength of titanium manufactured by selective laser melting: an in vitro study","","Titanium is used in metal-ceramic restorations for biocompatibility and cost efficiency, but veneering ceramic debonding remains a concern. The risk is linked to titanium’s high elasticity and a thick oxide layer with poor adhesion to ceramic. This in vitro study compares anodized 3D-printed titanium with non-anodized titanium and cobalt–chromium (CoCr) to assess metal-ceramic bond strength, using standardized veneering and mechanical testing with SEM-EDS analysis.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/effect-of-anodization-on-metal-ceramic-bond-strength-of-titanium-manufactured-by-selective-laser-melting-an-in-vitro-study/457775/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/effect-of-anodization-on-metal-ceramic-bond-strength-of-titanium-manufactured-by-selective-laser-melting-an-in-vitro-study/457775.png","ImageObject",300,407,{"name":92,"@type":93},"RuangKosong","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-19","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What was the main aim of the study?","Question",{"text":112,"@type":113},"To evaluate how anodization affects the metal-ceramic bond strength of 3D-printed titanium compared with non-anodized titanium and cobalt–chromium.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How were the titanium samples prepared and evaluated?",{"text":117,"@type":113},"Thirty metal plates (CoCr, non-anodized titanium, anodized titanium) were fabricated by selective laser melting. SEM-EDS assessed surface composition and morphology, followed by veneering and mechanical bond testing under ISO 9693-1:2019.",{"name":119,"@type":110,"acceptedAnswer":120},"What were the key findings on bond strength?",{"text":121,"@type":113},"Anodized titanium achieved higher bond strength than non-anodized titanium, but CoCr showed the highest strength. The anodization increase reached statistical significance, while the absolute difference was suggested to be unlikely to be clinically meaningful.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},457775,1790830151,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":19,"preview_urls":145},962090883219,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Mühl etal. BMCOral Health (2026) 26:33 BMC Oral Health  \n[https://doi.org/10.1186/s12903-025-07295-2](https://doi.org/10.1186/s12903-025-07295-2)  \nRESEARCH Open Access  \nEffect of anodization on metal-ceramic bond strength of titanium manufactured by selective laser melting: an in vitro study  \nAttila Mühl 1, János Kónya2, Iván Mandel 1*, KingaTurzó 1, Adél Németh 1, Péter Szabó3,4, Roland Told5,6, Ákos Nagy 1 and Gyula Marada 1  \nAbstract  \nBackground Titanium is used in metal-ceramic restorations due to its biocompatibility and cost-effectiveness, yet concerns persist regarding veneering ceramic debonding. This is largely attributed to titanium’s high elasticity and the formation of a thick, poorly adherent oxide layer. Anodization and additive manufacturing (SLM) have been proposed to improve titanium’s surface characteristics and bonding performance. This in vitro study aimed to evaluate the effect of anodization on the metal-ceramic bond strength of 3D-printed titanium compared to non-anodized titanium and cobalt–chromium (CoCr) alloy.  \nMethods Thirty metal plates (10 CoCr, 10 non-anodized titanium, 10 anodized titanium) were fabricated using selective laser melting (SLM) . SEM-EDS analysis was performed on the metal plates to evaluate surface composition and morphology. Veneering process and the subsequent mechanical testing followed ISO 9693-1:2019 standards. Bond strength was measured using a universal testing machine, and data were statistically analyzed via one-way ANOVA and Tukey HSD post hoc test (α = 0 . 05) .  \nResults The anodized group showed higher bond strength (59 .26 ± 4.19 MPa; 95% CI: 56 .9–61. 6) compared with non-anodized titanium (54 .37 ± 4.13 MPa; 95% CI: 52 .6–56. 1; p = 0 . 034, mean difference 4.89 MPa, Cohen’s d = 1 . 18) . Cobalt–chromium outperformed both titanium groups (86 .81 ± 3.72 MPa; 95% CI: 84 .8–88. 8; p \u003C 0. 001) . Although the anodization effect reached statistical significance, the ≈ 5 MPa difference is unlikely to be clinically meaningful according to ISO 9693 and prior clinical benchmarks.  \nConclusions Anodization enhances the bonding performance of 3D-printed titanium but does not match the strength of conventional CoCr frameworks. When titanium is selected for metal-ceramic systems, especially in highload cases, a bulkier framework design is recommended to minimize the risk of framework flexibility and failure. Keywords Metal-ceramic dental restorations, Titanium-ceramic interface, Veneering ceramic bonding, Ceramic chipping, 3D printed dental frameworks, Anodized titanium  \n*Correspondence: Iván Mandel [mandel.ivan@pte.hu](mandel.ivan@pte.hu)  \n1Medical Faculty, University of Pécs, Tüzér. Str. 1, Pécs H-7633, Hungary 2Dent-Art-Technik Kft, Csokonai Str. 10, Győr H-9024, Hungary 3Szentágothai Research Center, Environmental Analytical and Geoanalytical Research Group, Ifjúság Str. 20, Pécs H-7624, Hungary  \n4Institute of Geography and Earth Sciences, University of Pécs, Ifjúság útja 6, Pécs H-7624, Hungary  \n53D Printing and Visualization Centre, University of Pécs, Boszorkány Str. 2, Pécs H-7624, Hungary  \n6Medical Skills Education and Innovation Centre, Medical School, University of Pecs, Szigeti Str. 12, Pecs H-7624, Hungary  \n© The Author(s) 2025. Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the arti","cbCaikMJjiPGYRRH","https://ap.wps.com/l/cbCaikMJjiPGYRRH","pdf",2218517,"English","# Abstract\n# Methods\n# Results\n# Conclusions\n# Introduction\n## Background and rationale\n## Surface modification approaches","[{\"question\":\"What was the main aim of the study?\",\"answer\":\"To evaluate how anodization affects the metal-ceramic bond strength of 3D-printed titanium compared with non-anodized titanium and cobalt–chromium.\"},{\"question\":\"How were the titanium samples prepared and evaluated?\",\"answer\":\"Thirty metal plates (CoCr, non-anodized titanium, anodized titanium) were fabricated by selective laser melting. SEM-EDS assessed surface composition and morphology, followed by veneering and mechanical bond testing under ISO 9693-1:2019.\"},{\"question\":\"What were the key findings on bond strength?\",\"answer\":\"Anodized titanium achieved higher bond strength than non-anodized titanium, but CoCr showed the highest strength. The anodization increase reached statistical significance, while the absolute difference was suggested to be unlikely to be clinically meaningful.\"}]","Effect of anodization on metal-ceramic bond strength of titanium manufactured by selective laser melting: an in vitro study | PDF",1790750446,18,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ced3a6e41e602b24e37caddd7112f87e.webp",983,1310,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/b35caafffda491d8238239456288cb91.webp",982,1309,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/cee3b965afc54877e51ac5e85d5a2237.webp",981,1308,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/9a87c2a5120dce7bf456769201bdfaa6.webp",980,1306]