[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-653204-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-653204-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","econo-blast-portable-operating-instructions-single-chamber-blasters-p-100-p-150-p-300","Econo-Blast Portable Operating Instructions - Single Chamber Blasters - P-100 - P-150 - P-300","","Operating instructions for Econo-Blast single chamber blasters with manual and remote controls covering models P-100, P-150, and P-300. Includes an index-led guide to set-up, operation, daily and weekly maintenance, monthly maintenance guidance, troubleshooting, suggested spare parts by blasting hours, nozzle mounting assemblies, figures, and a parts list. Provides warranty terms, safety requirements for U.S. users, and step-by-step setup and operating procedures with protective equipment and control-hose wiring details.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/econo-blast-portable-operating-instructions-single-chamber-blasters-p-100-p-150-p-300/653204/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/econo-blast-portable-operating-instructions-single-chamber-blasters-p-100-p-150-p-300/653204.png","ImageObject",300,407,{"name":42,"@type":43},"Quinn Holloway","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":30},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What does the booklet cover for the P-100, P-150, and P-300 blasters?","Question",{"text":62,"@type":63},"It covers operation and general maintenance, including setup with manual and remote controls, daily/weekly maintenance, monthly guidance for certain piping, troubleshooting, and parts-related sections such as nozzle mounting and parts lists.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What safety requirements are emphasized for U.S. users?",{"text":67,"@type":63},"Protective equipment is required, including an air-fed hood with purifier and remote controls, canvas jacket, pants, and leather gloves. It also recommends using a carbon monoxide monitor and always using safety wires when joining blast hose or air hose couplings.",{"name":69,"@type":60,"acceptedAnswer":70},"How should the P-100 be prepared before blasting in manual operation?",{"text":71,"@type":63},"Fill with dry grit through the 2” top opening without overfilling above the sealing plunger area, connect the air hose with safety wires if quick disconnect couplings are used, ensure protective clothing, close main air valve and grit valve before opening compressor air valve, then open the main air valve when ready and gradually open the bottom grit valve for the proper air/grit mix.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},653204,1793141461,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":30,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":127,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":144},2336474466712,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","OPERATING INSTRUCTIONS  \nSINGLE CHAMBER BLASTERS  \nWITH MANUAL CONTROLS  \nP-100  \nP-150  \nP-300  \nWITH REMOTE CONTROL  \nP-150  \nP-300  \nINDEX  \n1.0 Set-up of P-100 with Manual Controls……………………………… Page 2  \n1.1 Set-up P-150 and P-300 with Manual Controls……………………… Page 2  \n1.2 Set-up of P-150 and P-300 with 680 Remote Controls……………… Page 3  \n2.0 Operation of P-100 with Manual Controls………………..………… Page 3  \n2.1 Operation of P-150 and P-300 with Manual Controls…….………… Page 4  \n2.2 Operation of P-150 and P-300 with 680 Pneumatic or Electric Remote Controls…………………………………………………………….. Page 5  \n3.0 Daily Maintenance………………………………………………….. Page 6  \n4.0 Weekly Schedule…………………………………………………… Page 6  \n4.1 Monthly Maintenance (for blasters with 1” piping only)…………… Page 7  \n5.0 Trouble Shooting……………………………………………….…… Page 8-10  \nto 9.0 10.0 Suggested Spare Parts for 1500 Blasting Hours……………………. Page 11  \n11.0 Nozzle Mounting Assemblies………………………………………. Page 12-14  \n12.0 Figures 1-2-3-3A………………………………………………….... Page 15-16  \n13.0 Parts List……………………………………………………………. Page 17-18  \nINTRODUCTION  \nThis booklet covers the operation and general maintenance of the P-100, P-150 and P-300 blasters. Read it carefully and keep it handy for future reference. If you have any questions regarding the operation and maintenance of your equipment, please contact your Empire representative who is qualified to assist you with service and offers a complete stock of replacement parts.  \nNOTE: Accessories such as optional air-fed hoods and purifiers have separate installation and operating instructions and are not included in this booklet.  \nWARRANTY  \nAll parts and equipment are guaranteed against defects in material and workmanship under normal use and service for one year from the date of installation. Material found to be defective within this one-year period will be replaced at no charge. This warranty does not apply to the normal wear items such as nozzles, blast hoses or other components exposed to or in direct contact with the blasting operation.  \nIMPORTANT NOTICE FOR U.S.A. USERS:  \nFor maximum safety, use protective equipment. NIOSH requires the use of an air-fed hood with purifier, remote controls, canvas jacket, pants and leather gloves. It is recommended that a (Carbon Monoxide) monitor be used. Always use “Safety Wires” when joining blast hose or air hose couplings. Make sure there is adequate air supply to both the operator’s hood and the blaster.  \n1.0  SET-UP P-100 WITH MANUAL CONTROLS (FIGURE 1-pg. 15)  \nA. Attach handle (1) and wheel bracket (16) with hardware provided.  \nB. Install side piping, grit valve, and attach air hose as shown on Figure 1. Use pipe connections.  \nC. Install pressure gauge (11) onto tee as shown.  \nD. Attach blast hose (22) to tank coupling (20) . Use coupling safety wires.  \nE. Insert nozzle (25) and nozzle washer (24) into adapter.  \nF. Attach nozzle adapter with nozzle and washer to hose coupling (23) .  \n1.1  SET-UP P-150 AND P-300 WITH MANUAL CONTROLS (FIGURE 2-pg. 15)  \nA. Attach handle (1) with hardware provided.  \nB. Attach blast hose (22) to tank coupling (20) . Use safety wires to secure coupling halves.  \nC. Install pressure gauge (11) onto TEE as shown.  \n1.2  SET-UP P-150 AND P-300 WITH 680 REMOTE CONTROLS  \nA. Attach handle (1) with hardware provided.  \nB. Located under your blaster is a manual Sure-Flo * grit valve (32) with tank coupling (20) installed. When connecting matching hose couplings be sure to use washer between couplings and safety wires.  \nC. Install washer (24) between nozzle (25) and nozzle coupling (23) . Thread nozzle into the threaded nozzle coupling on the end of the blast hose.  \nD. 680 Pneumatic Remote Control (Figure 3) is supplied with 30’ of dual line remote control hose (30). Connect one end to fittings on blast piping string. Connect black hose of dual line to fitting on elbow next to gauge. Connect yellow hose of dual line to fitting under ¼” pipe cross. Attach 77-SAF-STOP pneumatic control ","cbCaidx92GLLW4Ag","https://ap.wps.com/l/cbCaidx92GLLW4Ag","pdf",550048,"English","# Index\n## 1.0 Set-up of P-100 with Manual Controls\n## 1.1 Set-up P-150 and P-300 with Manual Controls\n## 1.2 Set-up P-150 and P-300 with 680 Remote Controls\n## 2.0 Operation of P-100 with Manual Controls\n## 2.1 Operation of P-150 and P-300 with Manual Controls\n## 2.2 Operation of P-150 and P-300 with 680 Pneumatic or Electric Remote Controls\n## 3.0 Daily Maintenance\n## 4.0 Weekly Schedule\n## 4.1 Monthly Maintenance (for blasters with 1” piping only)\n## 5.0 Trouble Shooting\n## 9.0 Suggested Spare Parts for 1500 Blasting Hours\n## 11.0 Nozzle Mounting Assemblies\n## 12.0 Figures 1-2-3-3A\n## 13.0 Parts List\n# Introduction\n# Warranty\n# Important Notice for U.S.A. Users\n# 1.0 Set-up P-100 with Manual Controls\n# 1.1 Set-up P-150 and P-300 with Manual Controls\n# 1.2 Set-up P-150 and P-300 with 680 Remote Controls\n# 2.0 Operation P-100 with Manual Controls","[{\"question\":\"What does the booklet cover for the P-100, P-150, and P-300 blasters?\",\"answer\":\"It covers operation and general maintenance, including setup with manual and remote controls, daily/weekly maintenance, monthly guidance for certain piping, troubleshooting, and parts-related sections such as nozzle mounting and parts lists.\"},{\"question\":\"What safety requirements are emphasized for U.S. users?\",\"answer\":\"Protective equipment is required, including an air-fed hood with purifier and remote controls, canvas jacket, pants, and leather gloves. It also recommends using a carbon monoxide monitor and always using safety wires when joining blast hose or air hose couplings.\"},{\"question\":\"How should the P-100 be prepared before blasting in manual operation?\",\"answer\":\"Fill with dry grit through the 2” top opening without overfilling above the sealing plunger area, connect the air hose with safety wires if quick disconnect couplings are used, ensure protective clothing, close main air valve and grit valve before opening compressor air valve, then open the main air valve when ready and gradually open the bottom grit valve for the proper air/grit mix.\"}]","Econo-Blast Portable Operating Instructions - Single Chamber Blasters - P-100 - P-150 - P-300 | PDF",1792886279,48]