[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-649151-105":59,"doc-detail-649151-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","e0-1-bel-electrical-symbols-legend-notes-for-electrical-installation","E0-1-BEL - Electrical Symbols Legend - Notes for Electrical Installation","","Electrical symbols legend and abbreviations list for electrical drawings, including panelboard and disconnect switch symbols, conduit and cable identification tags, and standard notation such as delta, phase, and conductor sizes. Provides electrical abbreviations (e.g., NEMA, NEC, UL-related terms) and tabulated legend items for low-voltage and power equipment identification. Includes 19 installation notes covering code compliance, equipment listing and approvals, diagrammatic drawing limitations, verification at jobsite, fire sealing at penetrations, grounding and conductor requirements, underground conduit specifications, seismic zone adherence, and equipment rating guidance.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/e0-1-bel-electrical-symbols-legend-notes-for-electrical-installation/649151/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/e0-1-bel-electrical-symbols-legend-notes-for-electrical-installation/649151.png","ImageObject",300,407,{"name":92,"@type":93},"Rainbow Cat","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-24","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What code standard is referenced for the electrical installation requirements?","Question",{"text":112,"@type":113},"The notes require the electrical installation to meet the minimum requirements of the 2017 National Electric Code as adopted by the State of Idaho and local building codes.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Are the drawings intended to show exact locations and materials?",{"text":117,"@type":113},"The drawings are described as diagrammatic only and show general intent. Exact locations and installation materials must be verified in the field with the actual installed equipment.",{"name":119,"@type":110,"acceptedAnswer":120},"What are the requirements for grounding conductors and conductor types?",{"text":121,"@type":113},"The notes specify equipment grounding conductors installed in conduit unless noted otherwise, using copper with green insulation for bonding and grounding. Power conductors must be THWN/THHN copper, with #10 and smaller solid and #8 and larger stranded, and Type NM cable is not permitted.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},649151,1792856671,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":52,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},962090769181,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","1  2  3  4  5  6  7  8  \nE0-1-BEL . DWG  \n\n| ELECTRICAL SYMBOLS LEGEND\u003Cbr>SURFACE MOUNTED PANELBOARD\u003Cbr> DISCONNECT SWITCH\u003Cbr>~~ ~~ ABOVE GRADE EXPOSED CONDUIT\u003Cbr>~~ ~~ ~~ ~~ ~~ ~~ ~~ ~~ ~~ ~~ UNDEGROUND CONDUIT\u003Cbr> CONDUITS IN/OUT OF EQUIPMENT\u003Cbr>DC1-1 CABLE/CIRCUIT TAG\u003Cbr>|  | ONE-LINE SYMBOLS LEGEND |  | ELECTRICAL ABBREVIATIONS LIST |  |  |  |  |  |  |  |  |  | HTHTGHTR HVHVAC\u003Cbr>HWP\u003Cbr>IC IGIMC | HEIGHT\u003Cbr>HEATING\u003Cbr>HEATER\u003Cbr>HIGH VOLTAGE\u003Cbr>HEATING, VENTILATING AND AIR CONDITIONING HYDRONIC WATER PUMP\u003Cbr>INTERRUPTING CAPACITY ISOLATED GROUND INTERMEDIATE METAL CONDUIT |  |  | | | NORMALLY CLOSED\u003Cbr>NATIONAL ELECTRICAL CODE\u003Cbr>NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION\u003Cbr>NON-FUSED SAFETY DISCONNECT SWITCH NOT IN CONTRACT NIGHT LIGHT NORMALLY OPEN NORMAL POWER FACTOR NOT TO SCALE\u003Cbr>OVERHEAD\u003Cbr>OVERLOADS\u003Cbr>PUBLIC ADDRESS\u003Cbr>PULL BOX OR PUSHBUTTON PNEUMATIC ELECTRIC PEDESTAL\u003Cbr>POWER FACTOR PHASE\u003Cbr>POST INDICATING VALVE POWER METER\u003Cbr>PANEL\u003Cbr>POWER POLE PAIR PRIMARY\u003Cbr>PROJECTION\u003Cbr>POWER ROOF VENTILATOR POTENTIAL TRANSFORMER POLYVINYL CHLORIDE (CONDUIT)\u003Cbr>POWER\u003Cbr>QUANTITY\u003Cbr>RECEPTACLE\u003Cbr>REQUIRED ROOM\u003Cbr>RIGID STEEL CONDUIT ROOF TOP UNIT SURFACE CONDUIT\u003Cbr>\u003Cbr>SCHEDULE\u003Cbr>SECONDARY SHEET SIMILAR SOLID NEUTRAL SPECIFICATION\u003Cbr>SPEAKER\u003Cbr>SPARE\u003Cbr>SURGE PROTECTION DEVICE SURFACE RACEWAY STAINLESS STEELSELECTOR SWITCH\u003Cbr>STOP/START PUSHBUTTONS STATION\u003Cbr>STANDARD\u003Cbr>SURFACE MOUNTED SUITABLE FOR USE AS |  |  | SWBD SYMSYSTEL\u003Cbr>SWITCHBOARD SYMMETRICAL\u003Cbr>SYSTEM TELEPHONE\u003Cbr>TEL/DATA TELEPHONE/DATA\u003Cbr>TERM TL\u003Cbr>TR\u003Cbr>T-STAT TTC TV TVTC TWPR\u003Cbr>\u003Cbr>TYP\u003Cbr>UCUEUG UHUT UTIL UV\u003Cbr>VVA VDT VERT VFD VOL\u003Cbr>WW/ WG WH W/O WP\u003Cbr>XFMRXFR\u003Cbr>TERMINAL\u003Cbr>TWIST LOCK\u003Cbr>TAMPER RESISTANT THERMOSTAT\u003Cbr>TELEPHONE TERMINAL CABINET TELEVISION\u003Cbr>TELEVISION TERMINAL CABINET TWISTED PAIR\u003Cbr>\u003Cbr>UNDER COUNTER\u003Cbr>UNDERGROUND ELECTRICAL\u003Cbr>UNDERGROUND\u003Cbr>UNIT HEATER UNDERGROUND TELEPHONE UTILITY\u003Cbr>UNIT VENTILATOR OR ULTRAVIOLET\u003Cbr>VOLT\u003Cbr>VOLT-AMPERES\u003Cbr>VIDEO DISPLAY TERMINAL VERTICAL\u003Cbr>VARIABLE FREQUENCY DRIVE VOLUME\u003Cbr>WATT WITH\u003Cbr>WIRE GUARD WATER HEATER WITHOUT WEATHERPROOF\u003Cbr>TRANSFORMER\u003Cbr>TRANSFER\u003Cbr>ANGLE @ AT\u003Cbr>'\u003Cbr>\"\u003Cbr>DELTA FEET INCHES\u003Cbr>\\# NUMBER Ø PHASE CL CENTER LINE PL PLATE |  | NOTES\u003Cbr>1. THE ELECTRICAL INSTALLATION SHALL MEET THE MINIMUM REQUIREMENTS OF THE 2017 NATIONAL ELECTRIC CODE AS ADOPTED BY THE STATE OF IDAHO AND LOCAL BUILDING CODES.\u003Cbr>2. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED AND APPROVED AND SUITABLE FOR THE INSTALLATION.\u003Cbr>3. DRAWINGS ARE DIAGRAMMATIC ONLY AND SHOW THE GENERAL INTENT OF LOCATIONS AND INSTALLATION REQUIREMENTS OF EQUIPMENT. EXACT LOCATIONSAND INSTALLATION MATERIALS REQUIRED SHALL BE VERIFIED IN FIELD WITH ACTUAL INSTALLED EQUIPMENT.\u003Cbr>4. ALL EXISTING CONDITIONS SHALL BE VERIFIED AT THE JOB SITE PRIOR TO BID SUBMITTALS.\u003Cbr>5. ALL WALL AND CEILING PENETRATIONS SHALL BE SEALED WITH MATERIALS APPROVED TO MAINTAIN FIRE RATINGS.\u003Cbr>6. EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSTALLED IN CONDUIT, UNLESS NOTED OTHERWISE.\u003Cbr>7. MULTIWIRED BRANCH CIRCUITS (SHARED NEUTRALS) SHALL NOT BE USED.\u003Cbr>8. PROVIDE PVC40 CONDUIT WITH PVC80 FITTINGS FOR ALL UNDERGROUND CONDUIT.\u003Cbr>9. PROVIDE EMT CONDUIT FOR ALL INDOOR AND OUTDOOR ABOVEGROUND CONDUIT PAINTED TO MATCH THE EXISTING CONDITIONS.\u003Cbr>10. PROVIDE THWN/THHN COPPER CONDUCTORS FOR ALL POWER CONDUCTORS. ALL CONDUCTORS \\#10 AND SMALLER SHALL BE SOLID; CONDUCTORS \\#8 AND LARGER SHALL BE STRANDED. TYPE NM CABLE IS NOT PERMITTED.\u003Cbr>11. ALL CABLE TERMINATIONS AND FITTINGS SHALL BE RATED FOR A MINIMUM OF 75C.\u003Cbr>12. PROVIDE BARE COPPER CONDUCTORS FOR BONDING. EQUIPMENT GROUNDING CONDUCTORS SHALL BE COPPER WITH GREEN INSULATION.\u003Cbr>13. ALL OUTDOOR EQUIPMENT SHALL BE NEMA TYPE-3R.\u003Cbr>14. PROVIDE CURRENT LIMITING FUSES FOR ALL FUSES IN ACCORDANCE WITH UL-4248 .\u003Cbr>15. ELECTRICAL SWITCHBOARDS SHALL HAVE A NEMA TYPE-1 RATINGS WITH COPPER BUSSING. THE CIRCUIT BREAKERS SHALL BE THE BOLT-ON TYPE.\u003Cbr>16. GROUND RODS SHALL BE CONE POINTED COPPER, 10' IN LENGTH, ","cbCaitQBKlyrYNOj","https://ap.wps.com/l/cbCaitQBKlyrYNOj","pdf",4276467,"English","# Electrical Symbols Legend\n## Electrical Abbreviations List\n## Electrical Installation Notes","[{\"question\":\"What code standard is referenced for the electrical installation requirements?\",\"answer\":\"The notes require the electrical installation to meet the minimum requirements of the 2017 National Electric Code as adopted by the State of Idaho and local building codes.\"},{\"question\":\"Are the drawings intended to show exact locations and materials?\",\"answer\":\"The drawings are described as diagrammatic only and show general intent. Exact locations and installation materials must be verified in the field with the actual installed equipment.\"},{\"question\":\"What are the requirements for grounding conductors and conductor types?\",\"answer\":\"The notes specify equipment grounding conductors installed in conduit unless noted otherwise, using copper with green insulation for bonding and grounding. Power conductors must be THWN/THHN copper, with #10 and smaller solid and #8 and larger stranded, and Type NM cable is not permitted.\"}]","E0-1-BEL - Electrical Symbols Legend - Notes for Electrical Installation | PDF",1792797505,25]