[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-203521-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-203521-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","e-frm-dc-regulatory-pm-sampler-single-event-filter-sampler-for-pm25pm10-ambient-air","E-FRM-DC REGULATORY PM SAMPLER - single-event filter sampler for PM2.5/PM10 ambient air","","E-FRM-DC regulatory PM sampler is a single-event filter sampler designed to determine daily PM2.5 or PM10 particulate concentrations in ambient air. Built for versatile fixed-site long-term monitoring or frequent relocations as an audit sampler, it supports straightforward setup and deployment with a full-color 4.3-inch touchscreen interface. The system meets current U.S. EPA PM2.5 Federal Reference Method requirements and can be configured with optional PM10/TSP/PM1 accessories for environmental, perimeter, and industrial monitoring.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/e-frm-dc-regulatory-pm-sampler-single-event-filter-sampler-for-pm25pm10-ambient-air/203521/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/e-frm-dc-regulatory-pm-sampler-single-event-filter-sampler-for-pm25pm10-ambient-air/203521.png","ImageObject",300,407,{"name":42,"@type":43},"นรินทร์","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-09-18","2026-09-04",true,{"@type":52,"interactionType":53,"userInteractionCount":22},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What is the purpose of the Met One E-FRM-DC sampler?","Question",{"text":62,"@type":63},"It determines daily PM2.5 or PM10 particulate concentrations in ambient air using a single-event filter sampling approach.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"How can the E-FRM-DC be deployed for different monitoring needs?",{"text":67,"@type":63},"It supports fixed permanent long-term sampling at a stationary site or relocation as an audit sampler for frequent moves.",{"name":69,"@type":60,"acceptedAnswer":70},"Which PM sampling configurations does the E-FRM-DC support?",{"text":71,"@type":63},"It can be configured for PM10 and also supports optional configurations for TSP, PM1, and PM2.5 using accessory components.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},203521,1788561642,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":107,"slug":108},7,40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":106,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":30,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":110},2336475104957,"https://ap-avatar.wpscdn.com/avatar/22000c4c6bd8a5076e1?x-image-process=image/resize,m_fixed,w_180,h_180&k=1787554080175789136","E-FRM-DC  \nREGULATORY PM SAMPLER  \nAPPLICATIONS:  \n• CRITERIA PM SAMPLING  \n• AUDIT SAMPLING  \n• REMOTE SAMPLING  \n• HEALTH STUDIES  \n• PERIMETER SAMPLING  \n• REGULATORY ENFORCEMENT  \nThe NEW and improved Met One Instruments, Inc. E-FRM-DC sampler is a single-event filter sampler to determine daily PM2.5 or PM10 particulate concentrations in ambient air.  \nThe E-FRM-DC has an innovative design and unique features that provide a versatile, reliable, and simple platform for your ambient air sampling needs. This versatile instrument is used for fixed or portable ambient particulate sampling applications. The E-FRMDC sampler is designed for easy setup and deployment, which allows it to be used for either permanent long-term sampling at a fixed site or as an audit sampler for frequent relocation.  \nThe E-FRM-DC can be configured for PM10 as well as TSP, PM1, and PM2.5 as optional accessories. Featuring modern components paired with innovative design and state-of-the-art manufacturing practices, the EFRM-DC is the premier single event sampler in the industry of particulate collection. The E-FRM-DC is ideal for Environmental Monitoring, Perimeter Sampling, and Industrial Monitoring.  \nThe E-FRM-DC user interface is a full-color, 4.3\"graphical touchscreen which utilizes intuitive control. The touchscreen was developed specifically to satisfy the recommendations of instrumentation operators. Data can be retrieved through any serial compatible data acquisition system or easily downloaded and transported with the filter on a USB drive.  \nMet One Instruments, Inc. | Phone: [541.471.7111 | Web: www.metone.com | Sales:](541.471.7111 | Web: www.metone.com | Sales:) [sales@metone.com | Service:](sales@metone.com | Service:) [service@metone.com](service@metone.com) MARCH 2021  \nFEATURES:  \n• Designed and tested to meet all current EPA PM2.5 Federal Reference Method specifications.  \n• Accommodates one EPA PM2.5 reference method 47mm sample filter cassette.  \n• Compatible with the VSCCTM cyclone or the classic WINS Impactor for PM2.5 sampling.  \n• Manufactured and supported in the United States at our ISO-9001 certified facilities.  \nINCLUDED ACCESSORIES:  \n􀀹 BX-802 EPA PM 10 Inlet  \n􀀹 BX-305 Leak Test Valve  \n􀀹 81210 PM 10 Adapter  \n􀀹 460128 FRM Filter Cassette (1 included with sampler)  \n􀀹 460122 FRM 47mm PTFE Filters  \n􀀹 80866-1 Ambient Temperature Sensor  \n􀀹 82537-2 Aluminum Stand  \n􀀹 Operator's Manual  \n􀀹 Software  \nOPTIONAL ACCESSORIES:  \no BX-808 PM2.5 VSCC™  \no Cyclone BX-804 PM2.5 WINS Impactor  \no BX-811 PM1 Cyclone  \no BX-803 TSP Inlet  \no BX-307 Flow Calibrator  \nMet One Instruments, Inc. | Phone: [541.471.7111 | Web: www.metone.com | Sales:](541.471.7111 | Web: www.metone.com | Sales:) [sales@metone.com | Service:](sales@metone.com | Service:) [service@metone.com](service@metone.com) MARCH 2021  \nSPECIFICATIONS  \nE-FRM-DC  \nMeasurement Principle Resulting Data Units  \nDesign Specifications  \nU.S. EPA Designations Main Inlet Type  \nPM2.5 Separator Type  \nPM10 Sampling Configuration Other Configurations Filter Type  \nFilter Holder  \nFilter Temperature Control Operating Temperature Operating Pressure Sample Events  \nFlow Rate  \nFlow Accuracy  \nFlow Records Vacuum Pump Data Collection  \nMemory Capacity Compatible Software User Interface Enclosure Type Deployed Dimensions Footprint Dimensions Weight  \nExternal Power Supply E-FRM-DC Power  \nProgrammable-event filter sampler for determination of particulate matter concentrations Micrograms per actual or standard cubic meter μg/m3 . Calculated from lab filter weights and actual or standard sampled volumes.  \nTitle 40 CFR, Part 50 Appendix L  \nRFPS-0315-221, RFPS-0216-231, RFPS-0316-232  \nEPA-pattern PM10 size-selective louvered inlet standard (MOI part no. BX-802)  \nOptions: BX-808 Very Sharp Cut Cyclone or BX-804 WINS Impactor Pass-through tube (used in place of cyclone) included for PM10 sampling.  \nCompatible with PM2.5 or PM1 SCC cyclones. TSP inlet available.  \n47mm PTFE disc filters ","cbCaic1rJleyJUcy","https://ap.wps.com/l/cbCaic1rJleyJUcy","pdf",4995488,"English","# Applications\n## Criteria PM sampling\n## Audit sampling\n## Remote sampling\n## Health studies\n## Perimeter sampling\n## Regulatory enforcement\n# Features and accessories\n## Key features\n## Included accessories\n## Optional accessories\n# Specifications overview","[{\"question\":\"What is the purpose of the Met One E-FRM-DC sampler?\",\"answer\":\"It determines daily PM2.5 or PM10 particulate concentrations in ambient air using a single-event filter sampling approach.\"},{\"question\":\"How can the E-FRM-DC be deployed for different monitoring needs?\",\"answer\":\"It supports fixed permanent long-term sampling at a stationary site or relocation as an audit sampler for frequent moves.\"},{\"question\":\"Which PM sampling configurations does the E-FRM-DC support?\",\"answer\":\"It can be configured for PM10 and also supports optional configurations for TSP, PM1, and PM2.5 using accessory components.\"}]","E-FRM-DC REGULATORY PM SAMPLER - single-event filter sampler for PM2.5/PM10 ambient air | PDF"]