[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646941-105":59,"doc-detail-646941-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","e-baltic-air-cooled-rooftop-packaged-units-installation-operating-maintenance-manual","e-BALTIC Air Cooled Rooftop Packaged Units - Installation, Operating & Maintenance Manual","","Installation, operating, and maintenance manual for e-BALTIC air cooled rooftop packaged units. Covers compliance with regulations and directives, safety codes, machine designation, and airflow limits, including EMC and F-GAS requirements. Includes warranty scope, key safety recommendations, delivery checks, rating plate guidance, storage and operating limits. Provides maintenance essentials such as condensate drains and handling of flammable gases, plus installation and electrical wiring procedures for units with gas burners, including R32 on-board safety and corrective maintenance.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/e-baltic-air-cooled-rooftop-packaged-units-installation-operating-maintenance-manual/646941/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/e-baltic-air-cooled-rooftop-packaged-units-installation-operating-maintenance-manual/646941.png","ImageObject",300,407,{"name":92,"@type":93},"Helloiii","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-09","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What regulations and directives does the manual cover for e-BALTIC units?","Question",{"text":113,"@type":114},"It covers compliance with regulations and directives, including safety codes, EMC directive compliance, and F-GAS regulation requirements.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What safety topics are addressed for units, especially when fitted with a gas burner?",{"text":118,"@type":114},"The manual provides main safety recommendations, notes for units fitted with a gas burner, label guidance, safety areas, and procedures related to powering up and intervention for flammable gas units.",{"name":120,"@type":111,"acceptedAnswer":121},"Which maintenance elements does the manual specify?",{"text":122,"@type":114},"It includes maintenance key guidance and maintenance procedures such as condensate drains, flammable gas handling, and corrective maintenance for R32 gas units.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},646941,1792811616,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":4},5909897196768,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","e-Baltic  \nAir cooled rooftop packaged units  \nInstallation, Operating and Maintenance  \ne-BALTIC-IOM-2022.02-EN  \nINSTALLATION, OPERATING & MAINTENANCE MANUAL  \nRef : e-BALTIC-IOM-2022.02-EN  \nINTRODUCTION................................................................................................................................................................... 1  \nGENERAL DESCRIPTION ........................................................................................................................................................... 1  \nCOMPLIANCE WITH REGULATIONS AND DIRECTIVES .............................................................................................................. 1  \nSAFETY CODES & REGULATIONS.............................................................................................................................................. 1  \nMACHINE DESIGNATION ......................................................................................................................................................... 2  \nAIRFLOW LIMITS...................................................................................................................................................................... 2  \nEMC DIRECTIVE COMPLIANCE ................................................................................................................................................. 3  \nF-GAS REGULATION .................................................................................................................................................................. 3  \nWARRANTY.............................................................................................................................................................................. 3  \nSAFETY .................................................................................................................................................................................... 4  \nNOTES FOR UNIT FITTED WITH GAS BURNER ........................................................................................................................... 5  \nLABELS ..................................................................................................................................................................................... 6  \nPED DIRECTIVE ........................................................................................................................................................................ 7  \nMAIN SAFETY RECOMMENDATIONS ....................................................................................................................................... 8  \nDELIVERY CHECKS.................................................................................................................................................................. 10  \nRATING PLATE ........................................................................................................................................................................ 10  \nSTORAGE ............................................................................................................................................................................... 10  \nOPERATING LIMITS................................................................................................................................................................ 11  \nMAINTENANCE KEY ............................................................................................................................................................... 12  \nCONDENSATE DRAINS............................................................................................................................................................ 12  \nFLAMMABLE GASES .......................................................................................................................................................... 13  \nLABELS OF A FLAMMABLE G","cbCailFlhHsBVKtP","https://ap.wps.com/l/cbCailFlhHsBVKtP","pdf",6105770,96,"English","# Introduction\n# General Description\n# Compliance with Regulations and Directives\n## Safety Codes & Regulations\n## EMC Directive Compliance\n## F-GAS Regulation\n# Warranty\n# Safety\n## Notes for Unit Fitted with Gas Burner\n## Labels\n# Delivery Checks\n# Storage\n# Operating Limits\n# Maintenance Key\n## Condensate Drains\n## Flammable Gases\n# Handling","[{\"question\":\"What regulations and directives does the manual cover for e-BALTIC units?\",\"answer\":\"It covers compliance with regulations and directives, including safety codes, EMC directive compliance, and F-GAS regulation requirements.\"},{\"question\":\"What safety topics are addressed for units, especially when fitted with a gas burner?\",\"answer\":\"The manual provides main safety recommendations, notes for units fitted with a gas burner, label guidance, safety areas, and procedures related to powering up and intervention for flammable gas units.\"},{\"question\":\"Which maintenance elements does the manual specify?\",\"answer\":\"It includes maintenance key guidance and maintenance procedures such as condensate drains, flammable gas handling, and corrective maintenance for R32 gas units.\"}]","e-BALTIC Air Cooled Rooftop Packaged Units - Installation, Operating & Maintenance Manual | PDF",1792777788,242]