[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662892-105":59,"doc-detail-662892-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","dytran-6032a-coaxial-cable-specifications","Dytran 6032A - Coaxial Cable Specifications","","This technical document details the engineering specifications for the Dytran 6032A series coaxial cable. It provides comprehensive physical and electrical characteristics, including a single-conductor shielded design, 50-ohm impedance, 32 pF/ft capacitance, and 0.80 microH/ft inductance. The cable features a white PTFE jacket, silver-plated copper conductor and braid, and is rated for high-temperature operations up to 200 degrees Celsius. The document also includes strict cable length tolerance guidelines and a schematic wiring diagram. This specification sheet serves as a reference for integration and quality control in technical applications requiring precise signal transmission cables. It outlines standardized build materials, voltage ratings, and minimal bend radius requirements essential for industrial or laboratory-grade instrumentation cabling.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/dytran-6032a-coaxial-cable-specifications/662892/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/dytran-6032a-coaxial-cable-specifications/662892.png","ImageObject",300,407,{"name":92,"@type":93},"pixelkiddo","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the impedance of the Dytran 6032A cable?","Question",{"text":112,"@type":113},"The Dytran 6032A cable has a characteristic impedance of 50 ohms.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What is the maximum operating temperature for this cable?",{"text":117,"@type":113},"The wire is rated for temperatures up to 200 degrees Celsius.",{"name":119,"@type":110,"acceptedAnswer":120},"What material is used for the cable conductor and shield?",{"text":121,"@type":113},"Both the conductor and the shield are composed of silver-plated copper.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662892,1793223100,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},962090883892,"https://ap-avatar.wpscdn.com/avatar/e00115db34f3e0f11b?x-image-process=image/resize,m_fixed,w_180,h_180&k=1790152879550218658","1  \n2  \n3  \n\n| DMGHMD  \u003Cbr>127-6032A   |  |  | H1   | D   |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| REVISIONS   |  |  |  |  |  |  |  |  |  |\n| REV.   | ECN   | DESCRIPTION   |  |  |  |  | BY/DATE   | CHK   | APPR   |\n| D   | 12753   | REDRAWN ON SOLIDWORKS   |  |  |  |  | LA  \u003Cbr>06/20/16   | AS   | LN   |\n\nPROPRIETARY AND CONFIDENTIAL  \n\n| WITHOUT THE WRITTEN PERMISSIONOF DYTRAN INSTRUMENTS INC.IS PROHIBITED   |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| 1CABLE LENGTH TOLERANCE   |  |  |  |  |\n| ENGLISH   |  | [METRIC]   |  |  |\n| ≤1FT   | +1/-0 IN   | ≤0.3m   | +25mm-0mm   |  |\n| >1 FT-5FT   | +2/-0 IN   | .0.3 m-1.5m   | +50mm-0mm   |  |\n| >5 FT-10 FT   | +4/-0 IN   | >1.5m-3m   | +100mm -0mm   |  |\n| >10 FT-25FT   | +6/-0 IN   | >3m-7.5m   | +150mm-0mm   |  |\n|  |  |  |  |  |\n\nD  \nC  \n\n| ING,CLEAR-   |  |  |  | B   |\n| --- | --- | --- | --- | --- |\n|  |  | 2  \u003Cbr>SINGLE CONDUCTOR SHIELDED CABLE   |  |  |\n|  |  | AWG   | 30-7/38 SILVER PLATED COPPER   |  |\n|  |  | TEMP   | 200 DEG C WIRE RATED   |  |\n|  |  | DIAMETER   | 0.074±.006   |  |\n|  |  | WITHSTANDING VOLTAGE   | 2000 VAC   |  |\n|  |  | JACKET   | WHT PTFE WRAP.005-.010 WALL   |  |\n|  |  | CONDUCTOR INSULATION   | EXTRUDED PTFE,NATURAL,Ø.033±.002   |  |\n|  |  | CAPACITANCE(SHIELD TO  \u003Cbr>CONDUCTOR)   | 32 pF/FT   |  |\n|  |  | IMPEDANCE   | 50 OHMS   |  |\n|  |  | INDUCTANCE   | .80 microH/FT   |  |\n|  |  |  |  |  |\n|  |  | SHIELD   | 38 AWG SILVER PLATED COPPER BRAID,  \u003Cbr>95%MIN COVERAGE,.054 NOM   |  |\n|  |  | MINIMUM BEND RADIUS   | .38 IN   |  |\n| UINL ESS OTHERWISE SPECIFIED:   | MASTER   |  |  |  |\n\n# SHRINK TUB\n\nB  \n# SCHEMATIC DIAGRAM\n\nA","cbCaiio5fwj8XFKB","https://ap.wps.com/l/cbCaiio5fwj8XFKB","pdf",130348,"English","# Technical Specifications\n## Electrical Characteristics\n## Physical Dimensions and Materials\n## Cable Length Tolerances\n## Schematic Diagram","[{\"question\":\"What is the impedance of the Dytran 6032A cable?\",\"answer\":\"The Dytran 6032A cable has a characteristic impedance of 50 ohms.\"},{\"question\":\"What is the maximum operating temperature for this cable?\",\"answer\":\"The wire is rated for temperatures up to 200 degrees Celsius.\"},{\"question\":\"What material is used for the cable conductor and shield?\",\"answer\":\"Both the conductor and the shield are composed of silver-plated copper.\"}]","Dytran 6032A - Coaxial Cable Specifications | PDF"]