[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663556-105":59,"doc-detail-663556-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","dwu-elevated-storage-tank-and-ground-storage-tank-design-standards-december-2012","DWU Elevated Storage Tank and Ground Storage Tank Design Standards - December 2012","","Manual defining minimum design criteria for elevated and ground storage tanks within the Dallas Water Utilities distribution and transmission network, dated December 2012. It is intended for engineering professionals involved in design and construction of DWU-owned and -operated tanks, and for ensuring facilities built by other entities meet DWU standards for future ownership and operation. The manual outlines guidance across siting, access, drainage, tank design, SCADA, disinfection, quality assurance, warranty, acceptance, and administrative requirements, emphasizing proper selection and appropriate application.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/dwu-elevated-storage-tank-and-ground-storage-tank-design-standards-december-2012/663556/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/dwu-elevated-storage-tank-and-ground-storage-tank-design-standards-december-2012/663556.png","ImageObject",300,407,{"name":92,"@type":93},"Dipper","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose of this manual for DWU tanks?","Question",{"text":112,"@type":113},"It outlines the minimum design criteria for elevated and ground storage tanks used within the Dallas Water Utilities network. It supports engineering work in design and construction and helps ensure compliance with DWU standards for future DWU ownership and operation.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Who is the manual intended to be used by?",{"text":117,"@type":113},"Engineering professionals responsible for designing and constructing DWU-owned and -operated storage tanks. It also applies to facilities built by non-DWU entities for DWU ownership later.",{"name":119,"@type":110,"acceptedAnswer":120},"Does the manual replace professional engineering judgment?",{"text":121,"@type":113},"No. The manual is a technical resource and does not substitute for the professional engineering judgment of the designer, who remains responsible for selection, reference, and appropriate application.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663556,1793229279,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},1374404997633,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","and ound  \nELEVATED STORAGE TANK & GROUND STORAGE TANK DESIGN MANUAL  \nDecember 2012  \nDWU Elevated Storage Tank and Ground Storage Tank Design Standards  \nDecember 2012  \nTABLE OF CONTENTS  \nPREFACE  \nACKNOWLEDGEMENTS ...................................................................................................... 3  \nINTRODUCTION .................................................................................................................. 4  \nCHAPTER 1 – ELEVATED STORAGE TANK DESIGN GUIDELINES  \nREFERENCES ...................................................................................................................... 5  \nFACILITY SITING ............................................................................................................... 7  \nVEHICULAR ACCESS ......................................................................................................... 7  \nSECURITY ACCESS AND SURVEILLANCE .............................................................................7  \nDRAINAGE .......................................................................................................................... 8  \nTANK DESIGN .................................................................................................................... 8  \nSCADA ............................................................................................................................ 15  \nDISINFECTION .................................................................................................................. 15  \nQUALITY ASSURANCE .......................................................................................................16  \nWARRANTY........................................................................................................................16  \nACCEPTANCE .................................................................................................................... 16  \nADMINISTRATIVE ..............................................................................................................17  \nCHAPTER 2 – GROUND STORAGE TANK DESIGN GUIDELINES  \nREFERENCES .................................................................................................................... 18  \nFACILITY SITING ............................................................................................................. 20  \nVEHICULAR ACCESS ....................................................................................................... 20  \nSECURITY ACCESS AND SURVEILLANCE .......................................................................... 20  \nDRAINAGE ........................................................................................................................ 21  \nTANK DESIGN .................................................................................................................. 21  \nSCADA ............................................................................................................................ 24  \nDISINFECTION .................................................................................................................. 24  \nQUALITY ASSURANCE .......................................................................................................24  \nDWU Elevated Storage Tank and Ground Storage Tank Design Standards  \nDecember 2012  \nWARRANTY........................................................................................................................25  \nACCEPTANCE .................................................................................................................... 25  \nADMINISTRATIVE ..............................................................................................................25  \nAPPENDIX  \nHYPOTHETICAL ELEVATED TANK SITE CONFIGURATION ............................... FIGURE \\#1  \nELEVATED STORAGE TANK VALVE CONFIGURATION ..................................... FIGURE \\#2  \nDWU Elevated Storage Tank De","cbCaigDVEoBOSLDi","https://ap.wps.com/l/cbCaigDVEoBOSLDi","pdf",295752,29,"English","# Preface\n## Acknowledgements\n# Introduction\n# Chapter 1 - Elevated Storage Tank Design Guidelines\n## References\n## Facility Siting\n## Vehicular Access\n## Security Access and Surveillance\n## Drainage\n## Tank Design\n## SCADA\n## Disinfection\n## Quality Assurance\n## Warranty\n## Acceptance\n## Administrative\n# Chapter 2 - Ground Storage Tank Design Guidelines\n## References\n## Facility Siting\n## Vehicular Access\n## Security Access and Surveillance\n## Drainage\n## Tank Design\n## SCADA\n## Disinfection\n## Quality Assurance\n## Warranty\n## Acceptance\n## Administrative\n# Appendix\n## Hypothetical Elevated Tank Site Configuration\n## Elevated Storage Tank Valve Configuration","[{\"question\":\"What is the purpose of this manual for DWU tanks?\",\"answer\":\"It outlines the minimum design criteria for elevated and ground storage tanks used within the Dallas Water Utilities network. It supports engineering work in design and construction and helps ensure compliance with DWU standards for future DWU ownership and operation.\"},{\"question\":\"Who is the manual intended to be used by?\",\"answer\":\"Engineering professionals responsible for designing and constructing DWU-owned and -operated storage tanks. It also applies to facilities built by non-DWU entities for DWU ownership later.\"},{\"question\":\"Does the manual replace professional engineering judgment?\",\"answer\":\"No. The manual is a technical resource and does not substitute for the professional engineering judgment of the designer, who remains responsible for selection, reference, and appropriate application.\"}]","DWU Elevated Storage Tank and Ground Storage Tank Design Standards - December 2012 | PDF",73]