[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663785-105":59,"doc-detail-663785-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","drawings-fire-alarm-sprinkler-installation-notes-and-symbol-legend","Drawings - Fire Alarm - Sprinkler - Installation Notes and Symbol Legend","","Installation and wiring guidance for fire alarm and related life-safety systems across electrical, mechanical, and architectural spaces. Specifies coordination with other trades for layout clearances, limits on flexible conduit use, mounting height practices, cable routing requirements, and underground conduit sealing. Includes rules for outlet box enclosure in smoke and fire-rated walls, conduit sizing minimums for main runs and device drops, and speaker placement for sound distribution. Provides a symbol legend for devices, barriers, and fire alarm components, plus renovation storage and NFPA 72 strobe coverage requirements.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/drawings-fire-alarm-sprinkler-installation-notes-and-symbol-legend/663785/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/drawings-fire-alarm-sprinkler-installation-notes-and-symbol-legend/663785.png","ImageObject",300,407,{"name":92,"@type":93},"Danger Angel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the key coordination and clearance requirements?","Question",{"text":112,"@type":113},"Coordinate with all trades for space requirements in mechanical rooms, corridors, shafts, and above ceilings. Maintain required clearances in front of devices and ensure no pipes/conduits are placed in the spaces above cabinets.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Are there restrictions on flexible conduit usage?",{"text":117,"@type":113},"Flexible conduit is permitted only for 6-foot devices or notification appliances. Flexible conduit must be provided for conduits passing through expansion joints.",{"name":119,"@type":110,"acceptedAnswer":120},"What rules apply to outlet boxes in smoke and fire walls?",{"text":121,"@type":113},"Outlet boxes over 16 square inches in smoke and fire walls must be enclosed with a five-sided enclosure using the same construction as the wall system. Boxes on opposite sides of a fire-rated wall require 12 inches horizontal separation or UL-listed fire resistant protection on five sides.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663785,1793231758,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},962090769052,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","F  \nAIM  \nAOM  \nANN  \nFACP  \nNAP  \nABBREVIATIONS / ACRONYMS  \n1. SEE ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR MATERIAL AND METHOD REQUIREMENTS FOR ELECTRICAL BOXES, CONDUITS, FITTINGS, MOUNTINGS, ETC.  \n2. FLEXIBLE CONDUIT IS ONLY PERMITTED FOR A 6-FOOT DEVICES OR NOTIFICATION APPLIANCES.  \n3. COORDINATE WITH ALL TRADES FOR SPACE REQUIREMENTS IN MECHANICAL ROOMS, CORRIDORS, SHAFTS, ABOVE CEILINGS, ETC. SPACES ABOVE CABINETS SHALL NOT HAVE PIPES AND/OR CONDUITS IN THEM. DO NOT RUN CONDUITS IN THE BOTTOM HALF OF PANELS TO ALLOW ROOM FOR BATTERIES.  \n4. FOR LOCATIONS OF MECHANICAL EQUIPMENT, SEE MECHANICAL PLANS. FOR EXACT LOCATIONS OF ELECTRICAL EQUIPMENT, SEE ELECTRICAL PLANS.  \n5. THE LOCATION OF DEVICES IN MECHANICAL ROOMS, ELECTRICAL ROOMS, MACHINE ROOMS, ETC. ARE SHOWN DIAGRAMATICALLY ONLY. DEVICES SHALL BE INSTALLED SO AS TO COORDINATE WITH ALL TRADES.  \n6. PLACE SPEAKERS IN MECHANICAL AND ELECTRICAL ROOMS FOR MAXIMUM SOUND DISTRIBUTION.  \n7. PROVIDE FLEXIBLE CONDUIT FOR ALL CONDUITS PASSING THROUGH  \nEXPANSION JOINTS. SEE ARCHITECTURAL DRAWINGS FOR ANY EXPANSION JOINTS.  \n8. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF ALL  \nCEILING MOUNTED EQUIPMENT.  \n9. CONTRACTOR SHALL VERIFY AND COORDINATE ALL MOUNTING HEIGHTS OF ALL DEVICES MOUNTED IN CASEWORK OR IN OR ABOVE COUNTERS WITH SPECIFIC EQUIPMENT FURNISHED.  \nOUTLET BOXES (MANUAL PULL STATIONS, TELEPHONE OUTLETS, SPEAKERS, ETC.) OVER 16 SQUARE INCHES IN SMOKE AND FIRE WALLS MUST BE  \nENCLOSED WITH A FIVE SIDED ENCLOSURE WITH SAME CONSTRUCTION AS WALL SYSTEM. WHERE OUTLET BOXES ARE ON OPPOSITE SIDES OF A FIRE RATED  \nWALL THERE MUST BE A 12 INCH HORIZONTAL SEPARATION BETWEEN THEM OR BOXES SHALL BE PROTECTED WITH UL LISTED FIRE RESISTANT MATERIAL ON 5 SIDES.  \n11. CONDUITS FOR MAIN RUNS SHALL BE 3/4 INCH MINIMUM. CONDUITS FOR  \nDEVICE DROPS SHALL BE 1/2 INCH MINIMUM.  \nMAINTAIN N. E.C. MINIMUM CLEARANCE IN FRONT OF ALL DEVICES AND OTHER FIRE ALARM EQUIPMENT. DETERMINE PROPER CLEARANCE BEFORE  \nINSTALLATION. DIMENSIONS OF EQUIPMENT SHOWN ARE BASED ONA  \nPARTICULAR MANUFACTURER. IF DIMENSIONS OF EQUIPMENT  \nFURNISHED DIFFER FROM THOSE ON THE DRAWINGS THEN CONTRACTORSHALL BE RESPONSIBLE FOR ENSURING THAT ALL EQUIPMENT FITS IN THE ROOM OR SPACE ALLOCATED WITH PROPER CLEARANCES.  \nALL UNDERGROUND CONDUIT RUNS ENTERING THE BUILDING SHALL BE  \nSEALED TO PREVENT THE ENTRANCE OF MOISTURE AND GASES.  \n14. CONTRACTOR SHALL VERIFY AND COORDINATE ALL CONNECTIONS TO  \nEQUIPMENT WITH SPECIFIC EQUIPMENT FURNISHED.  \nCONDUIT FOR FIRE ALARM SYSTEM SHALL BE RUN OVERHEAD UNLESS NOTED OTHERWISE.  \nTHE VERBIAGE \"SEE TYPICAL\" USED IN NOTES SHALL MEAN TO PROVIDE ALL ELECTRICAL ITEMS AT EACH SIMILAR LOCATION.  \nALL RECESSED MOUNTED CABINETS SHALL HAVE FOUR 3/4 INCH EMPTY  \nCONDUITS STUBBED ABOVE THE ACCESSIBLE CEILINGS.  \nCONNECTIONS TO MECHANICAL ARE BASED ON A PARTICULAR  \nMANUFACTURER. IF CONNECTIONS TO EQUIPMENT DIFFER FROM THAT SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING CONNECTIONS AS REQUIRED.  \nMOUNTING HEIGHTS OF WALL OUTLETS ABOVE FINISHED FLOOR SHALL BE AS INDICATED IN THE LEGEND AND IN THE FOLLOWING TABLE UNLESS NOTED OTHERWISE ON THE PLANS (MOUNTING HEIGHTS ARE TO CENTERLINE OF DEVICE):  \nWALL AUDIBLE NOTIFICATION APPLIANCES  \nWALL VISUAL NOTIFICATION APPLIANCES  \nWALL COMBINATION AUDIO/ VISUAL  \nNOTIFICATION APPLIANCE CONTROL EQUIPMENT CABINETS ADDRESSABLE INTERFACE MODULES (SURFACE MOUNTED) ADDRESSABLE INTERFACE MODULES  \n(FLUSH MOUNTED) SHUTDOWN RELAY NOTIFICATION APPLIANCE CIRCUIT  \n66 INCHES TO TOP OF DISPLAYS  \n56 INCHES  \n56 INCHES  \n66 INCHES TO TOP OF CABINET  \nEXTENDER PANEL  \nALL CONDUIT SHALL BE CONCEALED IN FINISHED WALLS OR ABOVE FINISHED CEILINGS UNLESS OTHERWISE INDICATED.  \nALL FIRE ALARM CABLE MUST BE INSTALLED IN CONDUIT. MC CABLE IS NOT ALLOWED.  \nSYMBOLS DESCRIPTION  \nLINETYPE-NEW WORK  \nLINETYPE-EXISTING TO REMAIN  \nLINETYPE-EXISTING TO BE REMOVED / RELOCATED  \nLINETYPE-EXTENT OF WORK BOUNDARY  \n1-HOUR FIRE RATED BARRIER","cbCaiifulxTdZkoQ","https://ap.wps.com/l/cbCaiifulxTdZkoQ","pdf",5278618,18,"English","# Abbreviations / Acronyms\n# Installation Notes\n## Coordination, Clearances, and Routing\n## Conduit, Boxes, and Cable Requirements\n## Mounting Heights and Device Placement\n# Outlet Box and Wall Protection Requirements\n# Conduit Sizing Minimums and Underground Sealing\n# Symbols Description (Device and Barrier Legend)","[{\"question\":\"What are the key coordination and clearance requirements?\",\"answer\":\"Coordinate with all trades for space requirements in mechanical rooms, corridors, shafts, and above ceilings. Maintain required clearances in front of devices and ensure no pipes/conduits are placed in the spaces above cabinets.\"},{\"question\":\"Are there restrictions on flexible conduit usage?\",\"answer\":\"Flexible conduit is permitted only for 6-foot devices or notification appliances. Flexible conduit must be provided for conduits passing through expansion joints.\"},{\"question\":\"What rules apply to outlet boxes in smoke and fire walls?\",\"answer\":\"Outlet boxes over 16 square inches in smoke and fire walls must be enclosed with a five-sided enclosure using the same construction as the wall system. Boxes on opposite sides of a fire-rated wall require 12 inches horizontal separation or UL-listed fire resistant protection on five sides.\"}]","Drawings - Fire Alarm - Sprinkler - Installation Notes and Symbol Legend | PDF",45]