[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-649709-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-649709-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","drawing-detail-checklist-site-plan-and-building-plans-checklist","DRAWING DETAIL CHECKLIST - Site Plan and Building Plans Checklist","","Comprehensive drawing detail checklist for legal survey and site planning, covering scaled depictions of existing and proposed structures, setbacks, sewage system clearances, and lot coverage calculations, along with service utility hook-ups location. Specifies required foundation (basement/crawlspace) layouts, plumbing, footing, column/post details, main/second floor framing and plumbing fixtures, heat loss calculations and duct design. Also includes roof plan requirements, building cross-sections with insulation and barrier values, engineered system layouts with engineer seals, and mechanical details such as ductwork and furnace size.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/drawing-detail-checklist-site-plan-and-building-plans-checklist/649709/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/drawing-detail-checklist-site-plan-and-building-plans-checklist/649709.png","ImageObject",300,407,{"name":42,"@type":43},"Dewi_Sukmawati","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",5,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"When is a legal survey and site plan required, and what must it include?","Question",{"text":63,"@type":64},"It applies only if the project is outside the site plan control area; contact the planning department to confirm requirements. The checklist requires scaled size and location of structures, setbacks and sewage clearances, lot coverage percentage, and locations of all site service utilities/hook-ups.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What information is required for the foundation (basement) plan?",{"text":68,"@type":64},"The basement layout must show plumbing fixtures and include structural footing details with width/diameter by depth, structural column/post attachment and spacing, and main floor framing details as seen above the basement. It must also specify whether the basement is finished/unfinished and, if only a crawlspace exists, whether it is heated or unheated.",{"name":70,"@type":61,"acceptedAnswer":71},"What mechanical and thermal documentation must be submitted?",{"text":72,"@type":64},"Heat loss calculations and duct design drawings are required, along with ductwork drawings and furnace size and specifications.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},649709,1792804311,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":55,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":22,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":80,"read_time":30},962094243415,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","DRAWING DETAIL CHECKLIST  \n􀀀 LEGAL SURVEY AND/OR SITE PLAN:  \nThis is only applicable if you are not within our site plan control area, please contact our planning department to determine if you are within that area and what will be required foryour approval.  \n- Size and location of all existing and proposed site structures, this drawing must be to scale (including any deck-porch-pool-shed areas)  \n- Provide all setbacks on existing and proposed structures, and sewage system clearances  \n- Calculate proposed lot coverage percent (%)  \n- All site service utilities/hook-ups to be located (septic or sewer/ well or waterline)  \n􀀀 FOUNDATION (BASEMENT) PLAN:  \n- Any existing/new basement layout (finished/unfinished) must show all plumbing fixtures  \n- All structural footing details (width or diameter by depth) including deck footings  \n- All structural column and/or post details (means of attachment and spacing)  \n- All main floor framing details, as seen above basement  \n- Identify finished or unfinished basement, if finished or partially finished provide detail  \n- If there is just a crawlspace, is it heated or unheated? details  \n􀀀 MAIN (GROUND) AND/OR SECOND (UPPER) FLOOR PLANS:  \n- Any existing floor layout details including all plumbing fixtures  \n- All structural beam, post and lintel sizes over all openings (specifications)  \n- All plumbing fixtures and all room names (ie. bedroom, bathroom, living room)  \n- All roof and ceiling framing details above main floor or second floor framing details  \n- Submit heat loss calculations and duct design drawings  \n􀀀 ROOF PLAN:  \n- Any existing roof layout details  \n- All roof lines to be drawn over profile of building below (indicate roof pitch)  \n- Conventional roof or engineered truss’ (truss layout/components require an approved engineered stamp)  \n􀀀 BUILDING CROSS SECTION(S):  \n- Any existing construction details as it relates to the new construction  \n- Detail full-height building cross section(s) (dimensions floor-to-floor & building height)  \n- Detail foundation, exterior wall & roof construction (insulation values/ air and vapour barriers)  \n􀀀 BUILDING DETAILS:  \n- Any engineered system (floor, lintels, beams, post and roof) requires approved layout/components & engineer seal  \n􀀀 MECHANICAL DETAILS  \n- Heat loss calculations  \n- Ductwork drawings  \n- Furnace size and specification","cbCaih40k6Le7Fbb","https://ap.wps.com/l/cbCaih40k6Le7Fbb","pdf",123890,"English","# Legal Survey and/or Site Plan\n## Foundation (Basement) Plan\n## Main and/or Second Floor Plans\n## Roof Plan\n## Building Cross Section(s)\n## Building Details\n## Mechanical Details","[{\"question\":\"When is a legal survey and site plan required, and what must it include?\",\"answer\":\"It applies only if the project is outside the site plan control area; contact the planning department to confirm requirements. The checklist requires scaled size and location of structures, setbacks and sewage clearances, lot coverage percentage, and locations of all site service utilities/hook-ups.\"},{\"question\":\"What information is required for the foundation (basement) plan?\",\"answer\":\"The basement layout must show plumbing fixtures and include structural footing details with width/diameter by depth, structural column/post attachment and spacing, and main floor framing details as seen above the basement. It must also specify whether the basement is finished/unfinished and, if only a crawlspace exists, whether it is heated or unheated.\"},{\"question\":\"What mechanical and thermal documentation must be submitted?\",\"answer\":\"Heat loss calculations and duct design drawings are required, along with ductwork drawings and furnace size and specifications.\"}]","DRAWING DETAIL CHECKLIST - Site Plan and Building Plans Checklist | PDF"]