[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-339986-105":59,"doc-detail-339986-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","dose-tracking-assessment-for-magnetic-resonance-guided-adaptive-radiotherapy-of-rectal-cancers","Dose tracking assessment for magnetic resonance guided adaptive radiotherapy of rectal cancers","","Magnetic resonance-guided adaptive radiotherapy (MRgART) on MR-Linac optimizes treatment plans using MR-based synthetic CT images and adapts target and organs-at-risk to each day’s anatomy. Conventional linac image-guided radiotherapy (IGRT) applies rigid realignment to daily anatomy and delivers the reference CT plan. This retrospective study evaluates MRgART versus IGRT for rectal cancer short-course radiotherapy and examines dose accumulation to support treatment accuracy.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/dose-tracking-assessment-for-magnetic-resonance-guided-adaptive-radiotherapy-of-rectal-cancers/339986/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/dose-tracking-assessment-for-magnetic-resonance-guided-adaptive-radiotherapy-of-rectal-cancers/339986.png","ImageObject",300,407,{"name":92,"@type":93},"Levi","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-14","2026-09-21",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the goal of comparing MRgART with IGRT in this study?","Question",{"text":112,"@type":113},"The study evaluates how MRgART performs versus IGRT for rectal cancer short-course radiotherapy, and it assesses the dose accumulation process to determine its value for improving treatment accuracy.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How were the IGRT-equivalent plans generated for comparison?",{"text":117,"@type":113},"For each adapted plan on daily MR-based sCT images, a second plan was created by recalculating the reference CT plan on the daily MR-based sCT images after rigid registration to simulate the IGRT workflow.",{"name":119,"@type":110,"acceptedAnswer":120},"What were the main findings regarding target coverage and dose discrepancies?",{"text":121,"@type":113},"All MRgART fractions met clinical target requirements, while IGRT failed to achieve expected target coverage in most fractions. Dose accumulation showed that IGRT produced significant variations and notable dosimetric differences, whereas MRgART was consistent between single fractions and accumulated doses.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},339986,1790690116,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":39,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":46,"preview_page_count":19,"preview_urls":144},7971461740909,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Xin et al. Radiation Oncology (2024) 19:114 [https://doi.org/10.1186/s13014-024-02508-4](https://doi.org/10.1186/s13014-024-02508-4)  \nRadiation Oncology  \nRESEARCH Open Access  \nDose tracking assessment for magnetic resonance guided adaptive radiotherapy of rectal cancers  \nXin Xin 1,2, Bin Tang2*, Fan Wu2, Jinyi Lang2, Jie Li2, Xianliang Wang2, Min Liu2, Qingxian Zhang 1, Xiongfei Liao2, Feng Yang 1,2 and Lucia Clara Orlandini2  \nAbstract  \nBackground Magnetic resonance-guided adaptive radiotherapy (MRgART) at MR-Linac allows for plan optimisation on the MR-based synthetic CT (sCT) images, adjusting the target and organs at risk according to the patient’s daily anatomy. Conversely, conventional linac image-guided radiotherapy (IGRT) involves rigid realignment of regions of interest to the daily anatomy, followed by the delivery of the reference computed tomography (CT) plan. This study aims to evaluate the effectiveness of MRgART versus IGRT for rectal cancer patients undergoing shortcourse radiotherapy, while also assessing the dose accumulation process to support the findings and determine its usefulness in enhancing treatment accuracy.  \nMethods Nineteen rectal cancer patients treated with a 1.5 Tesla MR-Linac with a prescription dose of 25 Gy (5 Gy x 5) and undergoing daily adapted radiotherapy by plan optimization based on online MR-based sCT images, were included in this retrospective study. For each adapted plan (TPadap), a second plan (TPIGRT) was generated by recalculating the reference CT plan on the daily MR-based sCT images after rigid registration with the reference CT images to simulate the IGRT workflow. Dosimetry of TPadap and TPIGRTwas compared for each fraction. Cumulative doses on the first and last fractions were evaluated for both workflows. The dosimetry per single fraction and the cumulative doses were compared using dose-volume histogram parameters.  \nResults Ninety-five fractions delivered with MRgART were compared to corresponding simulated IGRT fractions. All MRgART fractions fulfilled the target clinical requirements. IGRT treatments did not meet the expected target coverage for 63 out of 94 fractions (67 . 0%), with 13 fractions showing a V95 median point percentage decrease of 2. 78%(range, 1.65-4. 16%), and 55 fractions exceeding the V107% threshold with a median value of 15.4 cc (range, 6.0- 43.8 cc) . For the bladder, the median D 􀀞cc values were 18.18 Gy for the adaptive fractions and 19.60 Gy for the IGRT fractions. Similarly the median D cc values for the small bowel were 23.40 Gy and 25.69 Gy, respectively. No statistically significant differences were observed in the doses accumulated on the first or last fraction for the adaptive workflow, with results consistent with the single adaptive fractions. In contrast, accumulated doses in the IGRT workflow showed significant variations mitigating the high dose constraint, nevertheless, more than half of the patients still did not meet clinical requirements.  \n*Correspondence: Bin Tang [jackytang86@163.com](jackytang86@163.com)  \nFull list of author information is available at the end of the article  \n© The Author(s) 2024. Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or e","cbCaidfC09VBwokf","https://ap.wps.com/l/cbCaidfC09VBwokf","pdf",1723063,"English","## Background\n## Methods\n## Results\n## Conclusions\n## Keywords","[{\"question\":\"What is the goal of comparing MRgART with IGRT in this study?\",\"answer\":\"The study evaluates how MRgART performs versus IGRT for rectal cancer short-course radiotherapy, and it assesses the dose accumulation process to determine its value for improving treatment accuracy.\"},{\"question\":\"How were the IGRT-equivalent plans generated for comparison?\",\"answer\":\"For each adapted plan on daily MR-based sCT images, a second plan was created by recalculating the reference CT plan on the daily MR-based sCT images after rigid registration to simulate the IGRT workflow.\"},{\"question\":\"What were the main findings regarding target coverage and dose discrepancies?\",\"answer\":\"All MRgART fractions met clinical target requirements, while IGRT failed to achieve expected target coverage in most fractions. Dose accumulation showed that IGRT produced significant variations and notable dosimetric differences, whereas MRgART was consistent between single fractions and accumulated doses.\"}]","Dose tracking assessment for magnetic resonance guided adaptive radiotherapy of rectal cancers | PDF",1790033538,[145,149,153,157],{"page_no":8,"url":146,"width":147,"height":148},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/2e7b22e079b6bf6b33af400cb1372292.webp",983,1310,{"page_no":14,"url":150,"width":151,"height":152},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/d81c1eb610f7de3d16ecb8bf8f70b5ed.webp",982,1309,{"page_no":81,"url":154,"width":155,"height":156},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/ad6703a2e23bf37854cc3ad2f8889ee1.webp",981,1308,{"page_no":19,"url":158,"width":159,"height":160},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/fd633602312aa3fae9668e06b6550738.webp",980,1306]