[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-665576-105":59,"doc-detail-665576-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","doorways-gates-hallways-and-entrances-sections-11b-2064-11b-403-and-11b-404","Doorways, Gates, Hallways and Entrances - Sections 11B-206.4, 11B-403, and 11B-404","","Defines accessibility requirements for doorways, gates, hallways, and entrances into a voting area, including connection by accessible routes from transit stops, accessible parking, and public streets/sidewalks. Specifies maximum door opening/push-pull forces (5 pounds), minimum clear door widths (32 inches) and landing dimensions, strike/latch-side clearances, door sequence spacing, and wheelchair maneuvering slopes. Covers threshold height limits, beveled edges, smooth continuous door surfaces, and accessible hand-activated hardware placement and operation. Includes corridor clear width (44 inches minimum) and passing spaces for long hallways.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":20,"@type":76,"position":81},"https://docshare.wps.com/document/exam/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/doorways-gates-hallways-and-entrances-sections-11b-2064-11b-403-and-11b-404/665576/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/doorways-gates-hallways-and-entrances-sections-11b-2064-11b-403-and-11b-404/665576.png","ImageObject",300,407,{"name":92,"@type":93},"Dusta123","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the maximum force allowed to open or operate accessible doors?","Question",{"text":112,"@type":113},"The maximum effort to pull or push open a door must not exceed 5 pounds of force. The force required to operate door hardware (including the door handle) must also not exceed 5 pounds, measured separately.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What clear widths and landing dimensions apply to doors on an accessible route?",{"text":117,"@type":113},"Doors on the accessible route need a clear width of at least 32 inches measured between the door face and the stop with the door open 90 degrees. Door landings require 60 inches perpendicular to the door on the pull side and 48 inches on the push side.",{"name":119,"@type":110,"acceptedAnswer":120},"What corridor width and passing-space requirements apply when hallways are long?",{"text":121,"@type":113},"Corridors must have a clear width of at least 44 inches. If hallways exceed 200 feet, passing spaces of 60 inches by 60 inches are required at intervals no more than 200 feet apart, with a “T” intersection of two corridors or walks acceptable as a passing place.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},665576,1793305020,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":19,"category_name":20,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":39,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":46},962093541925,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","3. Doorways, Gates, Hallways and Entrances  \nSections 11B-206.4, 11B-403, and 11B-404  \nDoorways, gates, hallways, and entrances into the voting area shall be connected by an accessible route from public transportation stops, from accessible parking, and passenger loading zones, and from public streets and sidewalks if these routes are provided. (CCR, Section 11B-206 .4. )  \nThe maximum effort to pull or push open a door shall not exceed 5 pounds of force so that voters with disabilities and elderly voters will be able to enter the voting area. The force required to operate any door hardware such as a door handle shall also not exceed 5 pound of force. These two measurements should be taken separately. (CCR, Section 11B-404 .2.9. ) All doors on the accessible route shall have a clear width of at least 32 inches measured between the face of the door and the stop, with the door open 90 degrees. (CCR, Section 11B-404 .2.3. )  \nThe “Strike-side” or “Latch side” of the door is located at the edge of the door opposite the hinges. The strike-side requires a clear space on the pull side of the door that extends 18 inches beyond the edge of the door for interior doors and 24 inches for exterior doors. Some doors have an automatic closing device. If a door has a closer and the door hardware latches shut, the push side of the door requires a clear space that extends 12 inches beyond the edge of the door. (CCR, Sections 11B-404.2.4.1 and 11B-404 .3. ) All doors shall have a 60 inch landing perpendicular to the door on the pull-side of the door. On the push side, there shall be a 48 inch landing perpendicular to the door. See Figure 7a.  \nFigure 7a: Person using a wheelchair at a doorway illustrating doorway clear space for push side and pull side front approaches.  \nEntrances require landings with a maximum slope of 2.08 percent in all directions for the entire landing on each side of the door to allow a voter to open and maneuver around a door.  \nWhen two doors are in series, the distance between the two doors in series shall be at least 48 inches plus the width of the door when swinging into the space. (CCR, Sections 11B-404.2.4.1 and 11B-404 .2.6. ) See Figure 7B.  \nFigure 7b: Diagram showing different configurations of the maneuvering  \nclearance for doors in a series.  \nAll doors shall have a smooth, uninterrupted surface that is a minimum 10 inches high measured from the floor on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (CCR, Section 11B-404 .2.10. )  \nThe threshold at the bottom of a doorway may not exceed ½ inch in height. Any vertical surface at the threshold ¼ inch to ½ inch high shall be beveled. (CCR, Section 11B- 404.2.5.)  \n*Note – All measurements are inches.  \nFigure 8: Figure of ¼ inch vertical change in level and a ½ inch change in level  \nthat is beveled.  \nHand-activated door opening hardware, such as handles, pulls, latches, locks, and other operating devices shall be easy to operate with one hand without tight grasping, pinching, or twisting of the wrist. The force required to operate hand-activated door hardware shall be 5 pounds or less. The operable part of the door hardware shall be placed between 34 inches and 44 inches above the floor. Latching and locking doors that are hand-activated and are located on the accessible route shall be operable with one hand without requireing tight grasping pinching, or twisting of the wrist. (CCR, Sections 11B-404.2.7 and 11B-309 .4. ) See Figure 8.  \nFigure 9: Hand-activated door opening hardware including handles, pulls, and  \nlatches.  \nThe clear width for walking surfaces in corridors shall be 44 inches wide minimum. (CCR, Section 11B-403.5.1 Exception 2) . When hallways exceed 200 feet in length, there shall be passing spaces 60 inches by 60 inches, at intervals no more than 200 feet apart. A “T”intersection of two corridors or walks is an acceptable passing place. (CCR, Section 11B- 403.5.3. ) Se","cbCairNNVHLMG9dK","https://ap.wps.com/l/cbCairNNVHLMG9dK","pdf",642588,"English","# Doorways, Gates, Hallways and Entrances\n## Accessible routes to the voting area\n## Door operation and clearance measurements\n## Entrances, landings, and door sequences\n## Corridor widths and passing spaces","[{\"question\":\"What is the maximum force allowed to open or operate accessible doors?\",\"answer\":\"The maximum effort to pull or push open a door must not exceed 5 pounds of force. The force required to operate door hardware (including the door handle) must also not exceed 5 pounds, measured separately.\"},{\"question\":\"What clear widths and landing dimensions apply to doors on an accessible route?\",\"answer\":\"Doors on the accessible route need a clear width of at least 32 inches measured between the door face and the stop with the door open 90 degrees. Door landings require 60 inches perpendicular to the door on the pull side and 48 inches on the push side.\"},{\"question\":\"What corridor width and passing-space requirements apply when hallways are long?\",\"answer\":\"Corridors must have a clear width of at least 44 inches. If hallways exceed 200 feet, passing spaces of 60 inches by 60 inches are required at intervals no more than 200 feet apart, with a “T” intersection of two corridors or walks acceptable as a passing place.\"}]","Doorways, Gates, Hallways and Entrances - Sections 11B-206.4, 11B-403, and 11B-404 | PDF"]