[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-652750-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-652750-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","direct-expansion-compressed-air-dryers-operators-manual","DIRECT EXPANSION COMPRESSED AIR DRYERS - Operators Manual","","Operators manual for direct expansion compressed air dryers, covering functional description, safe dryer use, installation stages, start-up procedures, control panel operation, programming condensate discharge parameters, anomaly warnings, and remote signalling alarm. Includes guidance on before start-up checks, routine maintenance, troubleshooting, and decommissioning. Provides attachments such as refrigerant circuit, electric circuit diagram, technical data sheet, correction factors, dryer dimensions, and basic spare parts, plus symbols and labels used on the dryer and warranty terms.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/direct-expansion-compressed-air-dryers-operators-manual/652750/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/direct-expansion-compressed-air-dryers-operators-manual/652750.png","ImageObject",300,407,{"name":42,"@type":43},"Well Done","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",5,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What parts of the dryer are covered in the attachments to the manual?","Question",{"text":63,"@type":64},"The manual lists attachments including the refrigerant circuit, electric circuit diagram, technical data sheet, correction factors, dryer dimensions, and basic spare parts.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What safety and compliance guidance is provided before using the dryer?",{"text":68,"@type":64},"The manual recommends installation and maintenance/control activities be performed by qualified personnel and emphasizes following safety rules in the country where the system is used.",{"name":70,"@type":61,"acceptedAnswer":71},"What warranty coverage and exclusions are stated?",{"text":72,"@type":64},"The equipment is warranted to be free of defects for twelve months from placing in operation or eighteen months from shipment, whichever first occurs. It excludes corrosion, erosion, and normal wear and tear, and disclaims other warranties beyond title.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},652750,1793030458,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":55,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":107},5909892210082,"https://ap-avatar.wpscdn.com/avatar/56001069da27c9f41e8?x-image-process=image/resize,m_fixed,w_180,h_180&k=1789614185077863061","DIRECT EXPANSION COMPRESSED AIR DRYERS  \nOperators Manual  \nD12IN-A  \nD54IN-A  \nD144IN-A  \nD300IN-A  \nD600IN-A  \nD25IN-A  \nD72IN-AD180IN-A  \nD360IN-A  \nD780IN-A  \nD42IN-AD108IN-A  \nD225IN-A  \nD480IN-A  \nD950IN-A  \n- EN  \nCONTENTS  \n1. GENERAL INFORMATION  \n1.1 Functional description 2  \n1.2 Safe use of the dryer 2  \n2. INSTALLATION  \n2.1 Acceptance and transportation 3  \n2.2 Installation site 3  \n2.3Unpacking 3  \n2.4 Installation 4  \n3. START UP  \n3.1 Control panel 4  \n3.1.1 Keys function 5  \n3.1.2 Condensate discharge parameters programming 6  \n3.1.3 Anomaly warning 6  \n3.1.4 Remote signalling alarm 7  \n3.2 Before start up 7  \n3.3 Start up 7  \n4. MAINTENANCE, TROUBLESHOOTING AND DISMANTLING  \n4.1 Maintenance 8  \n4.2 Troubleshooting 8  \n4.3 Decommissioning 12  \nATTACHMENTS TO THIS MANUAL  \nA) Refrigerant circuit  \nB) Electric circuit diagram  \nC) Technical data sheet  \nD) Correction factors  \nE) Dryer dimensions  \nF) Basic spare parts  \n- EN  \nINTRODUCTION  \nThis manual is an integral part of the dryer you bought, and must remain with the machine even if this will be resold.  \nIt is highly recommended that the qualified*personnel for installation maintenance and/or control will fully comply with the contents of this manual and the prevention and safety rules in force in the country where the system will be used. In this way, not only the usage of the machine will be rational, but also the service will result cost effective.  \nIn case your dryer will present any kind of problem, please contact your local authorized Ingersoll Rand distributor.  \nPlease note that, when necessary, the use of original spare parts will ensure efficiency and long duration to your dryer.  \nDue to the continuous technological evolution, Ingersoll Rand reserves the right to modify the specifications contained in this manual without giving previous notice.  \nSYMBOLS AND LABELS USED IN THE MANUAL AND ON THE DRYER  \n\n| | |  |  | | Air inlet point. | | |  | |  | | Air outlet point. |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| |  | Read the Operators manual before attempt to start up the machine and to perform any service operation on the dryer. |  |  |  | |  | Pay particular attention to components or systems under pressure. |  |  |  |  |\n| |  | Pay particular attention to the indications preceded by these symbols. |  |  |  | |  | Pay particular attention to hot surfaces. |  |  |  |  |\n| |  | Installation, maintenance, and/or control operations preceded by these symbols must be performed exclusively by qualified personnel* . |  |  |  | |  | Pay particular attention to the risk of electric shock. |  |  |  |  |\n| |  | Condensate drain point. |  |  |  | |  | Rotation direction of the fan. |  |  |  |  |\n| |  | Pay particular attention to the risk of moving parts |  |  |  | |  | Explosion risk. |  |  |  |  |\n| |  | | Lifting point. |  |  | |  | |  | Don’t lift from this point. |  |  |\n| |  |  | Attention: Before performing any maintenance operation on this machine, do not forget to disconnect the electric supply, to completely discharge air pressure, and to refer to the Operators manual |  |  | |  | Pay particular attention to the risk of sharp edges |  |  |  |  |\n|  |  |  |  |  |  | |  |  |  |  |  |  |\n\n* Qualified personnel must be trained and certified in accordance with local laws and regulations.  \nWARRANTY  \nThe Company warrants that the equipment manufactured by it and delivered hereunder will be free of defects in material and workmanship for a period of twelve months from the date of placing the Equipment in operation or eighteen months from the date of shipment from the factory, whichever shall first occur. The Purchaser shall be obligated to promptly report any failure to conform to this warranty, in writing to the Company in said period, whereupon the Company shall, at its option, correct such nonconformity, by suitable repair to such equipment or, furnish a replacement part F.O. B. point of shipment, provided t","cbCaih28hC1rQhpU","https://ap.wps.com/l/cbCaih28hC1rQhpU","pdf",1587508,16,"English","# 1. GENERAL INFORMATION\n## 1.1 Functional description\n## 1.2 Safe use of the dryer\n# 2. INSTALLATION\n## 2.1 Acceptance and transportation\n## 2.2 Installation site\n## 2.3 Unpacking\n## 2.4 Installation\n# 3. START UP\n## 3.1 Control panel\n## 3.1.1 Keys function\n## 3.1.2 Condensate discharge parameters programming\n## 3.1.3 Anomaly warning\n## 3.1.4 Remote signalling alarm\n## 3.2 Before start up\n## 3.3 Start up\n# 4. MAINTENANCE, TROUBLESHOOTING AND DISMANTLING\n## 4.1 Maintenance\n## 4.2 Troubleshooting\n## 4.3 Decommissioning\n# ATTACHMENTS TO THIS MANUAL","[{\"question\":\"What parts of the dryer are covered in the attachments to the manual?\",\"answer\":\"The manual lists attachments including the refrigerant circuit, electric circuit diagram, technical data sheet, correction factors, dryer dimensions, and basic spare parts.\"},{\"question\":\"What safety and compliance guidance is provided before using the dryer?\",\"answer\":\"The manual recommends installation and maintenance/control activities be performed by qualified personnel and emphasizes following safety rules in the country where the system is used.\"},{\"question\":\"What warranty coverage and exclusions are stated?\",\"answer\":\"The equipment is warranted to be free of defects for twelve months from placing in operation or eighteen months from shipment, whichever first occurs. It excludes corrosion, erosion, and normal wear and tear, and disclaims other warranties beyond title.\"}]","DIRECT EXPANSION COMPRESSED AIR DRYERS - Operators Manual | PDF",1792882364]