[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-653602-105":59,"doc-detail-653602-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","dimplex-ultra-slim-storage-heaters-installation-instructions","Dimplex Ultra-Slim Storage Heaters - Installation Instructions","","Installation instructions for Dimplex Ultra-Slim storage heaters, covering the XL12N/XL18N/XL24N and XLS12N/XLS18N/XLS24N automatic twin-sensor models. Guidance includes careful handling due to the heater’s weight, secure wall fixing on a firm level surface, correct tools and heat-resisting cable requirements, minimum clearances, safe positioning away from sockets, windows, and contact objects, and electrical connection rules for ring circuits and fused spurs. It also provides commissioning steps and assembly and wall-mount fixing procedures, including options for different wall types.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/dimplex-ultra-slim-storage-heaters-installation-instructions/653602/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/dimplex-ultra-slim-storage-heaters-installation-instructions/653602.png","ImageObject",300,407,{"name":92,"@type":93},"nayy☆","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-25",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is required to keep the heater stable during installation?","Question",{"text":112,"@type":113},"The heater must be fixed securely to a wall and the feet must be mounted on a firm, level surface. Avoid irregular surfaces that could affect safe positioning.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which electrical connections are permitted for these storage heaters?",{"text":117,"@type":113},"XLN/XLSN models should not be connected to a 30 amp ring circuit, and XL/XLS24N storage heaters should not be connected to a fused spur. A double pole switch with at least 3mm contact separation must be incorporated in the fixed wiring in accordance with IEE wiring regulations.",{"name":119,"@type":110,"acceptedAnswer":120},"What steps are recommended before using the heater after installation?",{"text":121,"@type":113},"After commissioning, set both controls to maximum and leave for at least 48 hours. Rooms must be well ventilated during commissioning, and young children, caged birds, or people with respiratory complaints must not remain close to the heater.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},653602,1792961490,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":39,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":46},962090893153,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Dimplex Ultra-Slim Storage HeatersModels XL12N,XL18N,XL24N  \nTwin Sensor Models XLS12N Automatic,XLS18N Automatic,XLS24N Automatic  \n# IMPORTANT\n\nThese instructions should be read carefully and retained for future reference.Note also the information given on the appliance.  \nThis heater is VERY HEAVY.In order to maintain stabilityand to ensure its future safety in use,it is essential thatthe heater is FIXED SOUNDLY TOA WALL and that thefeet are mounted on a FIRM,LEVEL SURFACE.Careshould be taken to avoid irregular surfaces,such as mayresult from tiled surrounds partially protruding under theheater.It is important that the following instructions arestrictly followed.  \nThe installation of this appliance should be carried out bycompetent personnel and be in accordance with the currentIEE wiring regulations.For the assembly of the heater toolsrequired are a No.2 pozidriver,an electrical screwdriverwith a 4mm wide blade and a 8mm AF open ended or boxspanner.A small mirror will aid insertion of the front panelretaining screws.  \nOnly Heat Resisting Cable (min.rating T85)should be used.DO NOT COVER OR OBSTRUCT the surfaces of theappliance.  \nIT IS IMPORTANT THAT THE FIXING DEVICE CHOSEN ISAPPROPRIATE TO THE WALL MATERIAL TOWHICH THEHEATER IS BEING FIXED.SOME MODERN INTERNALBUILDING MATERIALSARE VERY LOW DENSITY BLOCKAND REQUIRE SPECIALISED FIXING DEVICES TOPROVIDE A SAFE,SECURE INSTALLATION.  \nDO NOT INSTALL the heater immediately below a fixedsocket outlet.  \nDO NOT POSITION under windows where curtains maycontact the heater.(See minimum clearances,stage 6).  \nDO NOT PLACE OBJECTS in contact with the heater.  \nTHEHEATERMUSTBEINSTALLEDWHEREITISIMPOSSIBLEFOR SWITCHESANDOTHER CONTROLSTOBE TOUCHEDBYA PERSON USING A BATH OR SHOWER.  \nIf,during any reassembly of the heater,a part of the thermalinsulation shows damage or deterioration which may impairsafety,it should be replaced with an identical part.  \nConnection to a 30 amp Ring Circuit  \n# XLN/XLSN STORAGE HEATERS SHOULD NOT BE CONNECTED TO A 30 AMP RING CIRCUIT.XL/XLS24N STORAGE HEATERS SHOULD NOT BE CONNECTED TO A FUSED SPUR.\n\nA means for disconnection must be incorporated in the fixed wiring by a double pole switch with a contactseparation of a minimum of 3mm and in accordance with the current IEE Wiring Regulations.  \nIMPORTANT-Due to the newness of materials the heater will produce a slight smell for the first few days of operation.ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN,CAGED BIRDS,OR PERSONS WITH RESPIRATORYCOMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY TO THE HEATER DURING THE COMMISSIONING PERIOD.To commission the heater set both controls to maximum and leave for a minimum of 48 hours,after this period the controlsshould be adjusted for everyday use -see operating instructions.  \nThis appliance is not intended for use by persons(including children)with reduced physical,sensory ormental capabilities,orlack of experience and knowledge,unless they have been given supervision for instruction concerning use of the applianceby a person responsible for their safety.Children should be supervised to ensure that they do not play with the appliance.  \nBricks are in packs of two.The pack cataloguenumber is XT 8300  \nXL12/XLS12N-12kWhXL18/XLS18N -18kWhXL24/XLS24N-24kWh8 Bricks(4 Packs)12 Bricks (6 Packs)16 Bricks(8 Packs)  \nAssembly of heater  \n1.Invert the carton and carefully lift carton off heater.Donot remove internal packaging pieces at this stage!  \n3.Secure the feet to base of heater using the Taptite  \nscrews provided (two for each foot).It is necessary onXL12N/XLS12N models,to remove base corner packagingpieces to locate feet in position.  \n2.Remove the feet and accessories bag from cornerfittings (accessories bag is located within one of the feet).  \n4.Loosen hexagon head front panel securing screws,by1-2 turns using screwdriver through aperture in each endpacking piece.  \n5.Stand heater on its feet and remove all packagingpieces.  \n7.If the floor is carpeted then the ca","cbCaikFRgAZS5GhK","https://ap.wps.com/l/cbCaikFRgAZS5GhK","pdf",3798434,"English","# IMPORTANT\n## Safety, tools, and cable requirements\n## Electrical connection and disconnection\n## Ventilation, commissioning, and user safety\n## Assembly of the heater\n## Wall bracket fixing and wall types","[{\"question\":\"What is required to keep the heater stable during installation?\",\"answer\":\"The heater must be fixed securely to a wall and the feet must be mounted on a firm, level surface. Avoid irregular surfaces that could affect safe positioning.\"},{\"question\":\"Which electrical connections are permitted for these storage heaters?\",\"answer\":\"XLN/XLSN models should not be connected to a 30 amp ring circuit, and XL/XLS24N storage heaters should not be connected to a fused spur. A double pole switch with at least 3mm contact separation must be incorporated in the fixed wiring in accordance with IEE wiring regulations.\"},{\"question\":\"What steps are recommended before using the heater after installation?\",\"answer\":\"After commissioning, set both controls to maximum and leave for at least 48 hours. Rooms must be well ventilated during commissioning, and young children, caged birds, or people with respiratory complaints must not remain close to the heater.\"}]","Dimplex Ultra-Slim Storage Heaters - Installation Instructions | PDF",1792893650]