[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-656231-105":59,"doc-detail-656231-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","digi-motor-installation-guide","Digi-Motor - Installation Guide","","Digi-Motor® Installation Guide details installation and commissioning procedures for the Azure™ Digi-Motor® variable speed direct drive blower motor used as a replacement for standard PSC and Genteq X-13 motors. The guide explains product description, safety warnings for trained HVAC professionals, removal of an existing motor, secure belly band mounting requirements to reduce noise and vibration, and configuration by matching horsepower and voltage. It also covers learn-mode auto sizing behavior and wiring/power connection sections.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/digi-motor-installation-guide/656231/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/digi-motor-installation-guide/656231.png","ImageObject",300,407,{"name":92,"@type":93},"Danger Angel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-03","2026-10-25",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the Azure™ Digi-Motor® intended for?","Question",{"text":112,"@type":113},"It is intended for direct drive centrifugal blower applications with continuous, air-over duty. The motor must be mounted in the air stream to ensure proper cooling.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Who should install the Digi-Motor®?",{"text":117,"@type":113},"Only trained and qualified HVAC professionals should install the motor. Power must be shut off before disconnecting or connecting wiring to prevent damage or injury.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the auto sizing learn mode work?",{"text":121,"@type":113},"During start-up learn mode, Azure™ runs for about 2 minutes to measure external static pressure, then assigns torque values to its speed taps to program the correct horsepower for the application.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},656231,1793006835,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":41},962090769052,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Digi-Motor® Installation Guide MARS No. 10860/10861  \n®  \n [marsdelivers.com](marsdelivers.com)  \n Digi-Motor® Installation Guide  \nDigi-Motor®  \nFor technical assistance with your Azure™ Digi-Motor® , call the MARS technical support hotline:  \n800-678-9888  \nM-F 8 am – 5 pm EST.  \nTable of Contents  \nProduct Description .........................................................................................................3  \nSafety..............................................................................................................................3  \nMounting & Configuring ..................................................................................................4  \nConnecting Power Wires .............................................................................................5-7  \nConnecting & Auto Sizing for PSC Applications .............................................................6  \nConnecting & Auto Sizing for X-13 Applications ............................................................7  \nAdjusting Motor Speeds ..................................................................................................8  \nOperating in Constant Fan Mode ..............................................................................9 , 10  \nTroubleshooting ............................................................................................................10  \nTypical Connections, PSC & X-13 Applications ............................................................11  \nPlease read the entire instruction manual before starting the installation.  \n©2014 MOTORS & ARMATURES, Inc.  \n2 AMlAl rRighStissresera regvied.sterTehdis catatrademloagrkmaofyMnoot btorser&epArrodumatucredes,inInwchoMle orARSinpparartt nuinmabnyerfsoarm wre traithoudemtwarrksitten permof Motorsiss&ionArfrommaturMeos,toIrsnc.& Armatures, Inc.   \n®  \nDigi-Motor® Installation Guide  \nProduct Description  \nThe Azure™ Digi-Motor® from MARS is a high efficiency variable speed direct drive blower motor for a multitude of applications. Azure™ is a replacement for both standard PSC and Genteq X-13 motors. Two motors  \ncover ratings from 1/5 HP to 1 HP at 115V or 230V and CW or CCW.  \nAzure™ features an auto sizing learn mode. In start-up learn mode, Azure™ runs for approximately 2 minutes measuring the external static pressure of the system application. Azure™ then assigns torque values to each of its speed taps self-programming itself to the correct horsepower for the application.  \nIf none of the four speeds provides perfect airflow for the application or if duplicate speeds are desired on 2 or more taps, an optional hand held programmer (MARS No. 08502) can be used. The programmer connects to Azure™ and displays the percentage of torque applied to the speed tap being energized. The percentage (motor speed) can then be increased or decreased and permanently set with the programmer. This tool overrides the motor torques established in the auto sizing mode.  \nUnlike other electronically commutated motors, an outboard surge protector is included within Azure’s ™ wire harness. This is a replaceable device (MARS No. 08593) .  \n• Outboard replaceable surge protector  \n• Adjustable speeds (with optional MARS No. 08502)  \n• 625 RPM constant fan speed tap  \n• Reversible rotation, dual voltage  \n• High efficiency 85%  \nSafety  \n\n|  WARNING! |\n| --- |\n| Use this motor only in applications for which it was designed.\u003Cbr>• The Azure™ Digi-Motor® is intended for use in direct drive centrifugal blower applications.\u003Cbr>• The Azure™ Digi-Motor® is designed for continuous, air-over duty and must be mounted in the air stream of an air-moving device to ensure proper cooling of the motor.\u003Cbr>• Do not use this motor in locations containing explosive vapors.\u003Cbr>• The ambient operating temperature range is\u003Cbr>-4˚F (-20˚C) to 131˚F (55˚C) . |\n\n• Multi-horsepower, direct drive  \n• Constant torque  \n• 4 Speeds  \n• Belly band mount  \n• No capacitor required  \n\n|  WARNING!","cbCaiiNrKvnZYmGS","https://ap.wps.com/l/cbCaiiNrKvnZYmGS","pdf",2876193,12,"English","# Product Description\n# Safety\n# Mounting & Configuring\n## Connecting Power Wires\n## Connecting & Auto Sizing for PSC Applications\n## Connecting & Auto Sizing for X-13 Applications\n# Adjusting Motor Speeds\n## Operating in Constant Fan Mode\n# Troubleshooting\n# Typical Connections, PSC & X-13 Applications","[{\"question\":\"What is the Azure™ Digi-Motor® intended for?\",\"answer\":\"It is intended for direct drive centrifugal blower applications with continuous, air-over duty. The motor must be mounted in the air stream to ensure proper cooling.\"},{\"question\":\"Who should install the Digi-Motor®?\",\"answer\":\"Only trained and qualified HVAC professionals should install the motor. Power must be shut off before disconnecting or connecting wiring to prevent damage or injury.\"},{\"question\":\"How does the auto sizing learn mode work?\",\"answer\":\"During start-up learn mode, Azure™ runs for about 2 minutes to measure external static pressure, then assigns torque values to its speed taps to program the correct horsepower for the application.\"}]","Digi-Motor - Installation Guide | PDF",1792967108]