[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-634636-105":59,"doc-detail-634636-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","df9fr-df1fr-dragon-fire-series-product-data-sheet-rev-222","DF9–FR, DF1–FR Dragon Fire Series - Product Data Sheet - Rev. 22–2","","Dragon Fire (DF) series multicard multiframes for high-capability processing, supporting up to nine single-slot DF series cards in the 10RU DF9–FR and one single-slot DF series module in the 1RU DF1–FR. Designed for configurable signal processing chains, with front-to-rear or front-to-side exhaust options, hot-swappable N+1 dual redundant power supplies, and remote monitoring through VistaLINK PRO with true SNMP. Specifications include programmable dual-plane reference timing and 525/625/tri-level HD reference inputs.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/df9fr-df1fr-dragon-fire-series-product-data-sheet-rev-222/634636/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/df9fr-df1fr-dragon-fire-series-product-data-sheet-rev-222/634636.png","ImageObject",300,407,{"name":92,"@type":93},"ahduag","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-26","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What card capacity do DF9–FR and DF1–FR support?","Question",{"text":112,"@type":113},"DF9–FR supports up to 9x single-slot DF series modules in any combination. DF1–FR holds 1x single-slot DF series module.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the series provide redundancy and remote monitoring?",{"text":117,"@type":113},"All frames use hot-swappable N+1 dual redundant power supplies to enable power and fan replacement without compromising critical signal paths. VistaLINK PRO provides true SNMP network communication for module and signal monitoring.",{"name":119,"@type":110,"acceptedAnswer":120},"What reference and timing specifications are listed for the switching reference?",{"text":121,"@type":113},"Reference inputs are 2x BNC supporting analog 525/625/tri-level HD, with reference timing provided by 2x independent programmable timing planes per input. Signal level is 1V p–p ±3dB with 75Ω termination.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},634636,1793030476,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":24},3985747870414,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","DF9–FR, DF1–FR Dragon Fire Series  \nHigh Capability Processing Multiframes  \nFeatures & Benefits  \n• Standard rack mountable  \n• Up to 9 cards in any configuration  \n• Front–to–rear (DF9), front–to–side (DF1) exhaust  \n• Up to 750W per slot  \n• DF9 with EXE APP for seamless control of Spine Leaf switch architecture  \nDragon Fire Series multiframes: the 10RU DF9–FR (left) and the 1RU DF1–FR (below), fully loaded  \nWhen applications for routing, high performance productions or high density processing are required, Evertz offers our  \nDragon Fire (DF) series of multicard frames, drawing on tens of thousands of Evertz’ award–winning EMX series multiframes.  \nThis series of frames allows cards with significantly larger individual size and power consumption to be matched in a multi– purpose frame. Products offered include video routing and audio routing, IP media gateways, IP routing and bulk processing.  \nAll cards in this series of frames can be installed vertically in the 10RU frame, and are installed horizontally in the 1RU variations. Cards can be mixed and matched within each frame to build complex signal processing chains.  \nAdditionally, all frames offer hot–swappable N+1 dual redundant power supplies that allow for power supply and fan replacement without compromising the integrity of critical signal paths and true remote monitoring of all modules and signals within the chassis from VistaLINK® PRO. This configuration provides the SNMP network communication interface from the VistaLINK® Network Management Software to the chassis over the local or wide area network.  \nREV. 22–2 • PRODUCT DATA SHEET • EVERTZ MICROSYSTEMS LTD. •  \nDF9–FR, DF1–FR Dragon Fire Series  \nHigh Capability Processing Multiframes  \nSpecifications Switching Reference:  \nReference Inputs: 2x BNC, analog 525/625/tri–level HD  \nReference Timing: 2x independent timing planes, programmable per input  \nSignal Level: 1V p–p ±3dB  \nImpedence: 75Ω terminating  \nConnectors: BNC per IEC 61169–8  \nAnnex A  \nMonitoring & Control:  \n• True SNMP  \n• VistaLINK® PRO  \nElectrical:  \nDF9–FR:  \nAC Mains Input: Auto–ranging,  \n180–240VAC, 50/60Hz Max . Operating Current:  \n15A (@ 220VAC  \nnominal) per supply Max. Power Consumption:  \n500W empty,  \n7500W fully loaded Max. Module Load: 750W per slot  \nCooling: Top–mounted fans,  \nfront–to–top exhaust Power Supply Configuration:  \nTBD  \nConnector: IEC 60320 C19  \n(1 per power supply) AC Cables Provided: NEMA 6–15P, 6 ft  \nDF1–FR:  \nAC Mains Input: Auto–ranging,  \n180–240VAC, 50/60Hz Max . Operating Current:  \n7A (@ 220VAC  \nnominal) per supply Max. Power Consumption:  \n100W empty,  \n850W fully loaded Cooling: Front and back  \nmounted fans,  \nfront–to–side exhaust Power Supply Configuration:  \n1x power supply standard, optional redundant supply requires separate inlet  \nConnector: IEC 60320 C13  \n(1 per power supply) AC Cables Provided: NEMA 6–20P, 6 ft  \nPhysical:  \nDF9–FR:  \nRack Size: 10RU  \nDimensions: 19” W x 17.5” H x 22 .5” D  \n(483 x 445 x 572mm) Module Capacity: 9x single–slot  \nDF series modules  \nWeight: Approx. 81.5 lbs (37 kg) with 3x fan modules, 2x power supplies, no slots occupied  \nDF1–FR:  \nRack Size: 1RU  \nDimensions: 19” W x 1.75” H x 22 .5” D  \n(483 x 45 x 572mm) Module Capacity: 1x single–slot  \nDF series module  \nWeight: Approx. 25 lbs (11 . 3 kg) including power supply, unoccupied slot  \nOrdering Information  \nDF9–FR  \nDF1–FR  \nOrdering Options:  \nDF9–FC  \nDF9–FAN  \nDF9–PSU  \nDF1–FRONTFAN  \nDF1–REARFAN  \nDF1–PSU  \nProcessing multiframe—holds up to 9x single–slot DF Series modules in any combination (package includes all frame controllers, fan modulesand 2x DF9–PSU)  \nProcessing multiframe—holds 1x single–slot DF Series module (package includes all fans and power supplies)  \nFrame controller for DF9–FR multiframe Fan module for DF9–FR multiframe 2500W DF9 power supply  \nFront fan module for DF1–FR multiframe Rear fan module for DF1–FR multiframe 1100W DF1 power supply  \nCopyright © Evertz Microsystems Ltd.","cbCaivcecERbfumH","https://ap.wps.com/l/cbCaivcecERbfumH","pdf",1408312,"English","# High Capability Processing Multiframes\n## Features & Benefits\n## Specifications\n### Switching Reference\n### Monitoring & Control\n### Electrical\n### Physical\n## Ordering Information","[{\"question\":\"What card capacity do DF9–FR and DF1–FR support?\",\"answer\":\"DF9–FR supports up to 9x single-slot DF series modules in any combination. DF1–FR holds 1x single-slot DF series module.\"},{\"question\":\"How does the series provide redundancy and remote monitoring?\",\"answer\":\"All frames use hot-swappable N+1 dual redundant power supplies to enable power and fan replacement without compromising critical signal paths. VistaLINK PRO provides true SNMP network communication for module and signal monitoring.\"},{\"question\":\"What reference and timing specifications are listed for the switching reference?\",\"answer\":\"Reference inputs are 2x BNC supporting analog 525/625/tri-level HD, with reference timing provided by 2x independent programmable timing planes per input. Signal level is 1V p–p ±3dB with 75Ω termination.\"}]","DF9–FR, DF1–FR Dragon Fire Series - Product Data Sheet - Rev. 22–2 | PDF",1792674198]