[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-382141-105":59,"doc-detail-382141-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","development-of-handheld-induction-heaters-for-magnetic-fluid-hyperthermia-applications-and-in-vitro-evaluation-on-ovarian-and-prostate-cancer-cell-lines","Development of handheld induction heaters for magnetic-fluid hyperthermia applications and in-vitro evaluation on ovarian and prostate cancer cell lines","","Magnetic-fluid hyperthermia (MFH) is an experimental cancer therapy aiming to raise tumor-site temperature to about 41 °C–47 °C by activating magnetic nanoparticles with an externally applied alternating magnetic field (AMF). High spatial-resolution AMF delivery remains challenging, limiting use near metallic implants. The work develops laparoscopic and transrectal handheld induction heaters and evaluates them in vitro on ovarian and prostate cancer cell lines, assessing both heating performance and cancer-cell killing while monitoring effects on normal cells.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/development-of-handheld-induction-heaters-for-magnetic-fluid-hyperthermia-applications-and-in-vitro-evaluation-on-ovarian-and-prostate-cancer-cell-lines/382141/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/development-of-handheld-induction-heaters-for-magnetic-fluid-hyperthermia-applications-and-in-vitro-evaluation-on-ovarian-and-prostate-cancer-cell-lines/382141.png","ImageObject",300,407,{"name":92,"@type":93},"moss~","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-09-24",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What is the goal of magnetic-fluid hyperthermia (MFH) in this study?","Question",{"text":113,"@type":114},"MFH aims to heat a tumor site to approximately 41 °C–47 °C by exciting magnetic nanoparticles using an externally applied alternating magnetic field, causing expected cell death under therapeutic conditions.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Why are smaller magnetic-field applicators needed?",{"text":118,"@type":114},"Current MFH applicators produce fields over relatively large areas, making them unsuitable for patients with metallic implants near the treatment region, which creates a clinical need for smaller applicators.",{"name":120,"@type":111,"acceptedAnswer":121},"What instruments were developed and how were they evaluated in vitro?",{"text":122,"@type":114},"A laparoscopic induction heater (LIH) and a transrectal induction heater (TRIH) were developed using miniature pancake coils in 3D-printed enclosures. Ovarian (SKOV-3, A2780) and prostate (PC-3, LNCaP) cancer cell lines were tested using Synomag®-D nanoparticles, with NIH3T3 normal cells used to check tolerability.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},382141,1790742705,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},962090895452,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","OPENACCESS  \nRECEIVED  \n3November2022  \nREVISED  \n15February2023  \nACCEPTED FOR PUBLICATION 24February2023  \nPUBLISHED  \n10March2023  \nOriginal content from this work maybe used under the terms ofthe Creative CommonsAttribution4.0 licence.  \nAny further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.  \nBiomed. Phys. Eng. Express9(2023)035010 [https:](https://doi.org/10.1088/2057-1976/acbeaf)[//](https://doi.org/10.1088/2057-1976/acbeaf)[doi.org](https://doi.org/10.1088/2057-1976/acbeaf)[/](https://doi.org/10.1088/2057-1976/acbeaf)[10.1088](https://doi.org/10.1088/2057-1976/acbeaf)[/](https://doi.org/10.1088/2057-1976/acbeaf)[2057-1976](https://doi.org/10.1088/2057-1976/acbeaf)[/](https://doi.org/10.1088/2057-1976/acbeaf)[acbeaf](https://doi.org/10.1088/2057-1976/acbeaf)  \nPAPER  \nDevelopment of handheld induction heaters for magneticﬂuid hyperthermia applications and in-vitro evaluation on ovarian and prostate cancer cell lines  \nJorge L Castro-Torres 1  , Janet Méndez2 , Madeline Torres-Lugo2  and Eduardo Juan3,∗   \n1 Bioengineering Graduate Program, University ofPuerto Rico, Mayagüez, Puerto Rico  \n2 Chemical Engineering Department, University ofPuerto Rico, Mayagüez, Puerto Rico  \n3 Electrical and Computer Engineering Department, University ofPuerto Rico, Mayagüez, Puerto Rico  \n∗ Author to whomany correspondence should be addressed.  \nE-mail:jorge.castro3@upr.edu and eduardoj.juan@upr.edu  \nKeywords: magneticﬁeld generators, magneticﬂuid hyperthermia, nanoparticles, laparoscopic and transrectal induction heaters Supplementary material for this article is available online  \nAbstract  \nObjective: Magneticﬂuid hyperthermia (MFH) is a still experimental technique found to have a potential application in the treatment ofcancer. The method aims to reach around41 °C–47 °Cin the tumor site by exciting magnetic nanoparticles with an externally applied alternating magneticﬁeld (AMF), where cell death is expected to occur. Applying AMFs with high spatial resolution is still a challenge. TheAMFs from current and prospective MFH applicators cover relativelylarge areas;being not suitable for patients having metallic implants near the treatment area. Thus, there will bea clinical need for smaller magneticﬁeld applicators. To this end, alaparoscopic induction heater (LIH) anda transrectal induction heater (TRIH) were developed. Methods: Miniature ‘pancake’ coils were wound and inserted into3D printed enclosures. Ovarian (SKOV-3, A2780) and prostate (PC-3, LNCaP) cancer cell lines were used to evaluate the instruments’ capabilities in killing cancer cells in vitro, using Synomag®-D nanoparticles asthe heat mediators. NIH3T3normal cell lines were also used with both devices to observe ifthese cells tolerated the conditions applied. Results: Magneticﬁeld intensities reached bythe LIHand TRIH were42 .6kAm−1at326kHz and26 .3kAm−1 at303kHz, respectively. Temperatures reached in the samples were41 °C bythe LIHand43 °C bythe TRIH. Both instruments successfully accomplished killing cancer cells, with minimal effects on normal cells. Conclusion: This work presents theﬁrst line ofhandheld medical induction heaters and have the potential to bea complement to existing cancer therapies. Signiﬁcance: These instruments could enable the developmentofMFH modalities that will facilitate the clinical translation ofthis thermal treatment.  \n1. Introduction  \nInduction heating (IH) has a gamut of applications, owing to its efﬁcient, safe, clean, and accurate method to deliver heat energy to a target object (metal or most electrically conductive materials) . IH implementations vary from cooking in domestic appliances to heating magnetically susceptible materials inside a patient’s body [1–4]. A signiﬁcant, but still mostly experimental IH application is magneticﬂuid hyperthermia (MFH), which refers to the technique of accumulating magnetic nanoparticles (MNPs) in a tumorigenic tissue and ","cbCaigf7LQkPJexo","https://ap.wps.com/l/cbCaigf7LQkPJexo","pdf",1368020,14,"English","# Abstract\n## Objective\n## Methods\n## Results\n## Conclusion\n## Significance\n# 1. Introduction","[{\"question\":\"What is the goal of magnetic-fluid hyperthermia (MFH) in this study?\",\"answer\":\"MFH aims to heat a tumor site to approximately 41 °C–47 °C by exciting magnetic nanoparticles using an externally applied alternating magnetic field, causing expected cell death under therapeutic conditions.\"},{\"question\":\"Why are smaller magnetic-field applicators needed?\",\"answer\":\"Current MFH applicators produce fields over relatively large areas, making them unsuitable for patients with metallic implants near the treatment region, which creates a clinical need for smaller applicators.\"},{\"question\":\"What instruments were developed and how were they evaluated in vitro?\",\"answer\":\"A laparoscopic induction heater (LIH) and a transrectal induction heater (TRIH) were developed using miniature pancake coils in 3D-printed enclosures. Ovarian (SKOV-3, A2780) and prostate (PC-3, LNCaP) cancer cell lines were tested using Synomag®-D nanoparticles, with NIH3T3 normal cells used to check tolerability.\"}]","Development of handheld induction heaters for magnetic-fluid hyperthermia applications and in-vitro evaluation on ovarian and prostate cancer cell lines | PDF",1790249245,35,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/988a7c941c54811dbe5d859c7f43e4c8.webp",983,1390,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/a7c86a8637df2ba15aa6b69d40e26362.webp",982,1388,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/68cd1c9a7bb11615b45ef4b3c2edb73a.webp",981,1387,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/cc7cd80ec75aa44dd070da598b11d64b.webp",980,1385]