[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-461073-105":3,"doc-detail-461073-en":81,"detail-sidebar-cat-0-en-105":116},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","development-and-rationale-for-the-consensus-auditory-perceptual-evaluation-of-voice-revised-cape-vr","Development and Rationale for the Consensus Auditory-Perceptual Evaluation of Voice – Revised (CAPE-Vr)","","Rationale: The Consensus Auditory Evaluation of Voice (CAPE-V) has circulated for more than 20 years, but issues over time have affected how the tool is administered and interpreted. Purpose: Using published literature, clinical experience, survey data, and practical considerations, the authors developed a revised protocol, new rating form, and updated instructions while preserving the instrument’s original purpose. Summary of Modifications: Changes include updated visual analog labeling, revised stimuli, modified rating options for pitch, loudness, resonance, added nasality, expanded space for task inconsistencies, vocal instability features, and overall impression, plus sections for recording and rating conditions.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/development-and-rationale-for-the-consensus-auditory-perceptual-evaluation-of-voice-revised-cape-vr/461073/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/development-and-rationale-for-the-consensus-auditory-perceptual-evaluation-of-voice-revised-cape-vr/461073.png","ImageObject",300,407,{"name":42,"@type":43},"Damian","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",11,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What problem does the CAPE-Vr address compared with the original CAPE-V?","Question",{"text":63,"@type":64},"The CAPE-Vr responds to issues that arose over time affecting the intended administration and interpretation of the original tool.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What are the key modifications introduced in the CAPE-Vr?",{"text":68,"@type":64},"Revisions include removing certain severity textual labels on visual analog scales, updating terminology and stimuli, revising rating options for pitch/loudness/resonance, adding a nasality category, and adding space for inconsistencies, vocal instability features, and overall comments.",{"name":70,"@type":61,"acceptedAnswer":71},"How is the CAPE-Vr intended to be used in voice assessment?",{"text":72,"@type":64},"The CAPE-Vr is designed to avoid common errors and provide a clear, useful assessment protocol for documenting auditory-perceptual evaluation of voice.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},461073,1790912161,{"code":4,"msg":82,"data":83},"success",{"doc_id":79,"user_id":84,"nickname":42,"user_avatar":85,"doc_module":4,"category_id":86,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":87,"file_id":88,"file_url":89,"file_type":90,"file_size":91,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":92,"language":93,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":94,"faqs":95,"seo_title":96,"seo_description":12,"update_tm":97,"read_time":98,"preview_page_count":33,"preview_urls":99},137451208677,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d",8,"Development and Rationale for the Consensus Auditory-Perceptual Evaluation of Voice –  \nRevised (CAPE-Vr)  \nGail B. Kempster, 1 Kathleen F. Nagle,2 Nancy Pearl Solomon3,4  \n1 Rush University, retired  \n2 Seton Hall University  \n3Walter Reed National Military Medical Center, Bethesda, MD 4Uniformed University of the Health Sciences, Bethesda, MD  \nRunning Head: Development and Rationale for the CAPE-Vr  \nCorresponding Author:  \nGail B. Kempster, PhD Associate Professor Emerita Rush University [gkempster@me.com](gkempster@me.com)  \nPresent address: 888 S Michigan Ave Unit 900 Chicago, IL 60605 USA  \nAuthor contributions. All authors contributed equally to the conceptualization, development, drafting and finalization of this work.  \nConflict of Interest: None of the authors of this manuscript have any real or potential conflicts of interest related to this manuscript.  \nDisclaimer: The views expressed in this article are those of the authors and do not necessarily reflect the official position of the Department of Defense or the U.S. Government.  \nData Availability Statement: Data sharing is not applicable to this article as no data sets were generated or analyzed for the current work.  \nDevelopment and Rationale for the CAPE-Vr 2  \nAbstract  \nRationale: The Consensus Auditory Evaluation of Voice (CAPE-V) has been in circulation for more than 20 years. Over the course of time, issues have arisen that have had an impact on the intended administration and interpretation of this common clinical tool.  \nPurpose: Based on published literature, clinical experience, recent survey data, and practical considerations, and while maintaining the original purpose of the instrument, the authors developed a revised protocol, new rating form, and updated instructions for the CAPE-V, now called the CAPE-V – Revised (CAPE-Vr) .  \nSummary of Modifications: Revisions to the CAPE-V include the following: removal of textual labels indicating regions of severity under each visual analog scale on the rating form, instead displaying terms indicating the direction of the lines; modification of several of the stimuli; revised rating options for pitch, loudness, and resonance, and an added category for nasality; added space to describe inconsistencies according to task; modified options for vocal instabilities and other features; and added space for comments about overall impression. The form also includes sections for documenting recording and rating conditions. Updated instructions are provided to clarify the CAPE-Vr protocol and correspond closely to the rating form.  \nConclusion. The CAPE-Vr is constructed to avoid common errors and problems identified from previous use of the original CAPE-V. This paper provides a rationale for each modification to the original CAPE-V, an updated form, and an example of a completed form. The CAPE-Vr is intended as a clear and useful assessment tool for documenting the auditory-perceptual evaluation of voice.  \nKeywords: CAPE-V; CAPE-Vr; voice quality; assessment, voice evaluation  \nDevelopment and Rationale for the CAPE-Vr 3  \nThe Consensus Auditory-Perceptual Evaluation of Voice (CAPE-V)1 was developed under the auspices of ASHA Special Interest Division (SID) 3: Voice and Voice Disorders (now Special Interest Group, SIG 3) by a group of speech-language pathologists, voice scientists, and psychoacousticians. The authors of the CAPE-V were interested in creating a brief but thorough and reliable tool for clinically evaluating voice in a standard way2,3 based on discussions and research presented at the conference. At the time, the 4-point GRBAS scale 4 was used most often in the international community to assess and document perceived voice quality according to five dimensions: Grade, Roughness, Breathiness, Asthenia, and Strain.5–7 The ordinal GRBAS scale, developed in Japan, was considered inadequate for research as it lacked specific instructions and provided only three discrete ordinal indicators of severity (1 = m","cbCairzfCkADL6je","https://ap.wps.com/l/cbCairzfCkADL6je","pdf",1572865,38,"English","# Abstract\n## Rationale\n## Purpose\n## Summary of Modifications\n## Conclusion\n# Background\n## Development of CAPE-V\n## Introduction and publication history\n## Purpose within voice examinations","[{\"question\":\"What problem does the CAPE-Vr address compared with the original CAPE-V?\",\"answer\":\"The CAPE-Vr responds to issues that arose over time affecting the intended administration and interpretation of the original tool.\"},{\"question\":\"What are the key modifications introduced in the CAPE-Vr?\",\"answer\":\"Revisions include removing certain severity textual labels on visual analog scales, updating terminology and stimuli, revising rating options for pitch/loudness/resonance, adding a nasality category, and adding space for inconsistencies, vocal instability features, and overall comments.\"},{\"question\":\"How is the CAPE-Vr intended to be used in voice assessment?\",\"answer\":\"The CAPE-Vr is designed to avoid common errors and provide a clear, useful assessment protocol for documenting auditory-perceptual evaluation of voice.\"}]","Development and Rationale for the Consensus Auditory-Perceptual Evaluation of Voice – Revised (CAPE-Vr) | PDF",1790760534,96,[100,104,108,112],{"page_no":22,"url":101,"width":102,"height":103},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/f28b7aaa82008f347bc0039a6f303dec.webp",983,1272,{"page_no":26,"url":105,"width":106,"height":107},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/e6255da6563e6676ef88a03f7d8604bb.webp",982,1270,{"page_no":30,"url":109,"width":110,"height":111},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/cc99d5e3c73245c8553ed0ad332bb39d.webp",981,1269,{"page_no":33,"url":113,"width":114,"height":115},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/5f51c49c6d5df631af8e45ac2b62ccfc.webp",980,1268,{"code":4,"msg":82,"data":117},[118,122,126,130,135,140,145,148,153,156,160],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":119,"show_sort_weight":120,"slug":121},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":123,"show_sort_weight":124,"slug":125},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":127,"show_sort_weight":128,"slug":129},"Exam",70,"exam",{"id":131,"doc_module":4,"doc_module_name":25,"category_name":132,"show_sort_weight":133,"slug":134},5,"Comic",60,"comic",{"id":136,"doc_module":4,"doc_module_name":25,"category_name":137,"show_sort_weight":138,"slug":139},6,"Technology",50,"technology",{"id":141,"doc_module":4,"doc_module_name":25,"category_name":142,"show_sort_weight":143,"slug":144},7,"Healthcare",40,"healthcare",{"id":86,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":146,"slug":147},30,"research-report",{"id":149,"doc_module":4,"doc_module_name":25,"category_name":150,"show_sort_weight":151,"slug":152},9,"Religion & Spirituality",20,"religion-spirituality",{"id":151,"doc_module":4,"doc_module_name":25,"category_name":154,"show_sort_weight":151,"slug":155},"World Cup","world-cup",{"id":157,"doc_module":4,"doc_module_name":25,"category_name":158,"show_sort_weight":157,"slug":159},10,"Lifestyle","lifestyle",{"id":161,"doc_module":4,"doc_module_name":25,"category_name":162,"show_sort_weight":131,"slug":163},19,"General","general"]