[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-650609-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-650609-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","designflex-fcsh-0008-3-bom-and-ceiling-plan-notes-axiom-vector","DesignFlex FCSH-0008-3 - BOM and Ceiling Plan Notes - Axiom Vector","","DesignFlex FCSH-0008-3 provides reference layout guidance and detailed bill of materials for a ceiling grid system. It specifies installation assumptions for non-seismic conditions and directs users to consult installation instructions and master parts sheets for required fasteners and panel detail views. The document includes ceiling plan view notes, bracket spacing guidance, system component lists for Axiom Vector beams, splices, tees, cables, and compatible Lyra panels, along with scale and nominal dimension references.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/designflex-fcsh-0008-3-bom-and-ceiling-plan-notes-axiom-vector/650609/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/designflex-fcsh-0008-3-bom-and-ceiling-plan-notes-axiom-vector/650609.png","ImageObject",300,407,{"name":42,"@type":43},"Logic","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":26},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What is the purpose of the DesignFlex FCSH-0008-3 notes and layout information?","Question",{"text":62,"@type":63},"It acts as a reference for specifying a DesignFlex system layout and related bill-of-materials items. It also provides guidance on how to interpret views, dimensions, and compatibility with panel products.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"Does the document cover seismic installation requirements?",{"text":67,"@type":63},"No. The notes state the shown conditions are for non-seismic installations and direct users to reference installation instructions for seismic design category A and B considerations.",{"name":69,"@type":60,"acceptedAnswer":70},"What fasteners are included in the BOM versus supplied by others?",{"text":71,"@type":63},"Angle brackets used within layouts include screws, washers, and nuts for fastening. If corner brackets are used, additional screws are required but not included; general fasteners like screws and rivets not listed in the BOM are to be supplied by others.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},650609,1792833982,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":26,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":33,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":123},1099513958762,"https://ap-avatar.wpscdn.com/avatar/1000023916a998db790?x-image-process=image/resize,m_fixed,w_180,h_180&k=1784791008015729253","| NOTES:\u003Cbr>THE EXAMPLE LAYOUT AND CORRESPONDING BOMSHOWN ARE MEANT TO BE USED AS REFERENCE POINTS WHEN SPECIFYING A DESIGNFLEX SYSTEM.\u003Cbr>IF YOU PLANTO USE THE EXACT LAYOUT SHOWN, OR ANY VARIATION THEREOF, CONSIDER THE FOLLOWING NOTES:\u003Cbr>1) DRAWING DETAILS SHOWA CEILING PLAN VIEW WHICH IS FROMAPLENUM POSITION LOOKING DOWN ONTO THE BACKSIDE OF THE CEILING SYSTEM. BOM LISTS DESCRIPTIONS THAT COORDINATE WITH THE DATA PAGES, AND THESE ITEM DESCRIPTIONS ARE BASED ON VIEWING THE FACE OF THE PRODUCTS.\u003Cbr>2)ANGLE BRACKETS AND CORNER BRACKETS ARE INSTALLED AT STANDARD 6\" OC ROUTE HOLE INCREMENTS ALONG THE MAIN BEAMS-ALL MAIN BEAMS ARE INSTALLED WITH ALIGNED ROUTE HOLES.\u003Cbr>3)ANGLE BRACKETS USED WITHIN LAYOUTS HAVE SCREWS, WASHERS, AND NUTS INCLUDED WITH THEM FOR FASTENING TO MAIN BEAMS. IF CORNER BRACKETS ARE USED IN THE SYSTEMTHEY WILL REQUIRESCREWS THAT ARE NOT INCLUDED AND NEED TO BE SUPPLIED BY OTHERS.\u003Cbr>4) SCREWS, RIVETS, AND OTHER GENERAL FASTENERS THAT ARE NOT INCLUDED IN BOMOR IN DETAILS BELOW, NEED TO BE SUPPLIED BY OTHERS. REFER TO INSTALLATION INSTRUCTIONS FOR DETAILS ON REQUIRED FASTENERS.\u003Cbr>5) HANGING LOCATIONS SHOWN BELOWARE REQURED FOR EXACT LAYOUT AND SHOULD NOT BE MOVED.\u003Cbr>6) CONDITIONS SHOWN ARE FOR NON-SEISMIC INSTALLATIONS (SEISMIC DESIGN CATEGORY A,B) -REFERENCE INSTALLATION INSTRUCTIONS FOR CONSIDERATIONSAND REQUIREMENTS FOR SEISMIC INSTALLATIONS.\u003Cbr>7) BOM DOES NOT ACCOUNT FORTHE USE OF SCRAP OR EXCESS MATERIAL CUT FROM OTHER ITEMS. |  | DF1612S4SP08-4\" AXIOM VECTOR-BILL OF MATERIALS\u003Cbr>ITEM QTY STOCK NUMBER DESCRIPTION 1 6 7500/7501 12' ID/HD Suprafine Main Beam 2 4 75AB60L Suprafine 60 Deg. Left Angle Bracket 3 6 75AB60R Suprafine 60 Deg. Right Angle Bracket 4 2 75AB60D Suprafine 60 Deg. Double Angle Bracket 5 4 XM756048 Suprafine 60 Deg. Cross Tee-48in MBS 6 8 XM7548 Suprafine Perimeter Cross Tee-48in MBS 7 12 PAC Perimeter Agle Clip 8 8 AX4VESTR Axiom Vector 4\" Straight 9 10 AXTBC AXTBC 10 16 AX4SPLICEB Axiom Splice Plate 11 18 AC1210 Aircraft Cable 12 18 ACHC Aircraft Cable Hardware |\n| --- | --- | --- |\n| 8) REFER TO MASTER PARTS SHEET, PANEL SHEET, AND INSTALLATION INSTRUCTIONS ILLUSTRATIONS SHEET FOR SPECIFIC DETAIL VIEWS AND DIAGRAMS OFALL PARTS AND PIECES LISTED IN BOM.\u003Cbr>\u003Cbr>18'\u003Cbr>(216)\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>16' 1\"\u003Cbr>( 193)\u003Cbr>25' 9\"\u003Cbr>(309)\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>DF1612S6SP08-6\" AXIOM VECTOR-BILL OF MATERIALS ITEM QTY STOCK NUMBER DESCRIPTION 1 6 7500/7501 12' ID/HD Suprafine Main Beam 2 4 75AB60L Suprafine 60 Deg. Left Angle Bracket 3 6 75AB60R Suprafine 60 Deg. Right Angle Bracket 4 2 75AB60D Suprafine 60 Deg. Double Angle Bracket 5 4 XM756048 Suprafine 60 Deg. Cross Tee-48in MBS 6 8 XM7548 Suprafine Perimeter Cross Tee-48in MBS 7 12 PAC Perimeter Agle Clip 8 8 AX4VESTR Axiom Vector 6\" Straight 9 10 AXTBC AXTBC 10 16 AX4SPLICEB Axiom Splice Plate 11 18 AC1210 Aircraft Cable 12 18 ACHC Aircraft Cable Hardware\u003Cbr>EXAMPLE LAYOUT AND BOMSHOWN WITH LYRA PANELS\u003Cbr>PANEL PRODUCT FAMILIES COMPATIBLE WITH THIS LAYOUT: LYRA PBAND OPTIMA PB\u003Cbr>REFERENCE DATA PAGE FOR PANEL CARTON QUANTITIES\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>7\u003Cbr>C\u003Cbr>\u003Cbr>DETAIL BAXTBC & PAC SCALE 1/2\u003Cbr>\u003Cbr>10\u003Cbr>\u003Cbr>DETAIL AAXTBC SCALE 1/2\u003Cbr>DETAIL CAX4SPLICEB SCALE 1/2\u003Cbr>\u003Cbr>\u003Cbr>11\u003Cbr>\u003Cbr>15\u003Cbr>\u003Cbr>LYRA PANELS-NOT INCLUDED ITEM QTY STOCK NUMBER DESCRIPTION 13 8 100003 Lyra 9/ 16\" Square Tegular-60 Deg. 48 in Base Triangle 14 4 100018 Lyra 9/ 16\" Square Tegular-60 Deg. 48 in Base Right Parallelogram 15 4 100019 Lyra 9/ 16\" Square Tegular-60 Deg. 48 in Base Left Parallelogram\u003Cbr>\u003Cbr>6\u003Cbr>\u003Cbr>12\u003Cbr>\u003Cbr>7\u003Cbr>\u003Cbr>9\u003Cbr>\u003Cbr>8\u003Cbr>\u003Cbr>13\u003Cbr>\u003Cbr>\u003Cbr>14\u003Cbr>|  |  |\n| CEILING PLAN VIEW\u003Cbr>SCALE 1 / 14 | \u003Cbr>DESIGNFLEX FCSH-0008-3 DRAWN BY: SDP DATE: 6/ 17/2019 PD\u003Cbr>These drawings show typical conditions which the Armstrong products depicted are installed. They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of local building codes, laws, statutes, ordinances, rules and regulations (Legal Requirements) that may be a","cbCaipHqsGIqFr0U","https://ap.wps.com/l/cbCaipHqsGIqFr0U","pdf",1578314,"English","# Notes for DesignFlex system reference layout\n## Ceiling plan view and installation assumptions\n## Bill of materials (BOM) for Axiom Vector\n## Compatible Lyra panel items and reference scales\n## General parts and fastener requirements","[{\"question\":\"What is the purpose of the DesignFlex FCSH-0008-3 notes and layout information?\",\"answer\":\"It acts as a reference for specifying a DesignFlex system layout and related bill-of-materials items. It also provides guidance on how to interpret views, dimensions, and compatibility with panel products.\"},{\"question\":\"Does the document cover seismic installation requirements?\",\"answer\":\"No. The notes state the shown conditions are for non-seismic installations and direct users to reference installation instructions for seismic design category A and B considerations.\"},{\"question\":\"What fasteners are included in the BOM versus supplied by others?\",\"answer\":\"Angle brackets used within layouts include screws, washers, and nuts for fastening. If corner brackets are used, additional screws are required but not included; general fasteners like screws and rivets not listed in the BOM are to be supplied by others.\"}]","DesignFlex FCSH-0008-3 - BOM and Ceiling Plan Notes - Axiom Vector | PDF"]