[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664236-105":59,"doc-detail-664236-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","design-requirements-for-architects-engineers-2025-v14","Design Requirements for Architects & Engineers - 2025 v14","","Design Requirements for Architects & Engineers documents standard requirements for Nationwide Children’s Hospital design and construction. It directs designers to discuss any deviations with the Engineering Project Manager and proceed according to provided guidance. The table of contents organizes requirements by construction divisions, covering document and drafting standards, facility remediation, post-tensioning, masonry, structural metal framing and fabrication, wood/plastics/composites work, thermal and moisture protection, damp proofing and waterproofing, insulation, fire and smoke protection, firestopping, joint protection, and openings scheduling and components.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/design-requirements-for-architects-engineers-2025-v14/664236/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/design-requirements-for-architects-engineers-2025-v14/664236.png","ImageObject",300,407,{"name":92,"@type":93},"Putri","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29",true,{"@type":101,"interactionType":102,"userInteractionCount":19},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What is the purpose of this document?","Question",{"text":111,"@type":112},"To establish standard requirements for Nationwide Children’s Hospital design and construction.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What should designers do if they need to deviate from the document requirements?",{"text":116,"@type":112},"Discuss all deviations with the Engineering Project Manager and then proceed based on the direction given.",{"name":118,"@type":109,"acceptedAnswer":119},"How are the requirements organized in the document?",{"text":120,"@type":112},"They are organized by construction divisions and sections, including areas like concrete, metals, wood/plastics/composites, thermal and moisture protection, and openings.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},664236,1793246739,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":138,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":128,"read_time":143},962085571259,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","Design Requirements for Architects & Engineers  \n2025 v14  \nHiggins-5/27/25  \nHallowell-6/23/2025  \nPrepared By:  \nNCH Engineering Services Department Ross Hall, Room R4000, 614-355-1600  \nThe intent of this document is to establish standard requirements for Nationwide Children's Hospital design and construction. Designers shall discuss all deviations from this document with the Engineering Project Manager and then proceed based upon  \nthe direction given.  \nTable of Contents  \nDIVISION 00: NCH REQUIREMENTS ................................................................................................................................... 8  \n00.00.10 – Summary of Work: ....................................................................................................................................... 8  \n00.00.11 – NCH Reference Standards: ........................................................................................................................... 8  \n00.42.19 – Reference Standards: ................................................................................................................................... 8  \n00.60.10 Document Standards-Layer & Drafting Standard: ..................................................................................... 10  \n00.78.00 – Project Closeout Deliverables: ................................................................................................................... 11  \n00.79.00 – Above Ceiling System Identification Matrix: ............................................................................................. 15  \nDIVISION 01: GENERAL REQUIREMENT ........................................................................................................................... 16  \n01.00.12 – Facility Remediation:.................................................................................................................................. 16  \nDIVISION 03: CONCRETE................................................................................................................................................... 16  \n03.00.00 – General Design Conditions:........................................................................................................................ 16  \n03.36.50 – Post Tensioning: ......................................................................................................................................... 16  \nDIVISION 04: MASONRY ................................................................................................................................................... 16  \n04.00.00 – General Design Conditions:........................................................................................................................ 16  \nDIVISION 05: METALS ....................................................................................................................................................... 17  \n05.10.00 – Structural Metal Framing: .......................................................................................................................... 17  \n05.50.00 – Metal Fabrication: ...................................................................................................................................... 17  \nDIVISION 06: WOOD, PLASTICS AND COMPOSITES......................................................................................................... 17  \n06.05.00 – Common Work Results for Wood, Plastics, and Composites: .................................................................. 17  \n06.10.00 – Rough Carpentry: ....................................................................................................................................... 17  \n06.41.00 – Architectural Wood Casework: .................................................................................................................. 17  \nDIVISION 07: THERMAL AND MOISTURE PROTECTION ...................................","cbCaia3AAEPi00hp","https://ap.wps.com/l/cbCaia3AAEPi00hp","pdf",4247497,234,"English","# DIVISION 00: NCH REQUIREMENTS\n## 00.00.10 – Summary of Work\n## 00.00.11 – NCH Reference Standards\n## 00.42.19 – Reference Standards\n## 00.60.10 Document Standards-Layer & Drafting Standard\n## 00.78.00 – Project Closeout Deliverables\n## 00.79.00 – Above Ceiling System Identification Matrix\n# DIVISION 01: GENERAL REQUIREMENT\n## 01.00.12 – Facility Remediation\n# DIVISION 03: CONCRETE\n## 03.00.00 – General Design Conditions\n## 03.36.50 – Post Tensioning\n# DIVISION 04: MASONRY\n## 04.00.00 – General Design Conditions\n# DIVISION 05: METALS\n## 05.10.00 – Structural Metal Framing\n## 05.50.00 – Metal Fabrication\n# DIVISION 06: WOOD, PLASTICS AND COMPOSITES\n## 06.05.00 – Common Work Results for Wood, Plastics, and Composites\n## 06.10.00 – Rough Carpentry\n## 06.41.00 – Architectural Wood Casework\n# DIVISION 07: THERMAL AND MOISTURE PROTECTION\n## 07.05.00 – Common Work Results for Thermal & Moisture Protection\n## 07.10.00 – Damp proofing and Waterproofing\n## 07.21.00 – Thermal Insulation\n## 07.21.16 – Blanket Insulation\n## 07.70.00 – Roof and Wall Specialties and Accessories\n## 07.80.00 – Fire and Smoke Protection\n## 07.84.00 – Technology Room Firestopping\n## 07.90.00 – Joint Protection\n# DIVISION 08: OPENINGS\n## 08.06.00 – Schedules for Openings\n## 08.12.13 – Hollow Metal Frames\n## 08.31.00 – Access Doors and Panels","[{\"question\":\"What is the purpose of this document?\",\"answer\":\"To establish standard requirements for Nationwide Children’s Hospital design and construction.\"},{\"question\":\"What should designers do if they need to deviate from the document requirements?\",\"answer\":\"Discuss all deviations with the Engineering Project Manager and then proceed based on the direction given.\"},{\"question\":\"How are the requirements organized in the document?\",\"answer\":\"They are organized by construction divisions and sections, including areas like concrete, metals, wood/plastics/composites, thermal and moisture protection, and openings.\"}]","Design Requirements for Architects & Engineers - 2025 v14 | PDF",590]