[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662950-105":59,"doc-detail-662950-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","design-of-fasteners-for-facade-panels-made-of-natural-stone-and-ceramic-tiles-tr-062","Design of fasteners for facade panels made of natural stone and ceramic tiles - TR 062","","Technical Report TR 062 provides design methods for façade-panel fasteners based on a European Technical Assessment (ETA) and EAD 330030-00-0601. It covers fasteners for natural stone façade panels (except slate) per EN 1469 and ceramic tiles (stoneware) per EN 14411, focusing on local load transmission from façade panels into the fastener. The document defines design and safety concepts, ultimate limit state verification, static analysis for load determination, characteristic value determination, and resistance verification for breakout/pull-out and steel failure under tension, shear, and combined actions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/design-of-fasteners-for-facade-panels-made-of-natural-stone-and-ceramic-tiles-tr-062/662950/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/design-of-fasteners-for-facade-panels-made-of-natural-stone-and-ceramic-tiles-tr-062/662950.png","ImageObject",300,407,{"name":92,"@type":93},"RizkyPratama_92","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the scope of TR 062 regarding fastener design?","Question",{"text":112,"@type":113},"TR 062 provides design methods for façade fasteners that are supported by a European Technical Assessment (ETA) based on EAD 330030-00-0601. It specifies how to use characteristic resistances and distances from the ETA to design fasteners for natural stone façade panels (except slate) and ceramic tiles (stoneware).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which standards and material types are covered for façade panels?",{"text":117,"@type":113},"The report applies to natural stone façade panels according to EN 1469 (excluding slate) and ceramic tiles according to EN 14411. It also notes that natural stone in practice may differ from the tested material in the ETA.",{"name":119,"@type":110,"acceptedAnswer":120},"How does TR 062 treat verification of fastener resistance at the ultimate limit state?",{"text":121,"@type":113},"It presents verification methods for breakout or pull-out resistance and for steel failure resistance. These are addressed under tension loads, shear loads, and combined tension and shear, as part of the ultimate limit state design approach.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662950,1793223702,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":46,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":31},962094243231,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Design of fasteners for facade panels made of natural stone (except slate) and ceramic tiles (stoneware)  \nTR 062  \nJuly 2018 Amended March 2024  \nContents  \n1 SCOPE OF THE TECHNICAL REPORT ......................................................................................3  \n1.1 Fastener .........................................................................................................................................3  \n1.2 Façade panel .................................................................................................................................3  \n1.3 Type and direction of load ..............................................................................................................4  \n1.4 Specific terms used in this TR .......................................................................................................4  \n2 DESIGN AND SAFETY CONCEPT...............................................................................................6  \n2.1 Design concept ..............................................................................................................................6  \n2.2 Ultimate limit state ..........................................................................................................................6  \n3 STATIC ANALYSIS .......................................................................................................................7  \n3.1 General...........................................................................................................................................7  \n3.2 Loads acting on fastener ................................................................................................................8  \n3.2.1 Determination of the fastener loads at the fixing points of the façade panel .................................8  \n3.2.2 Determination of the fastener loads on the fixing points of reveal angle .......................................8  \n3.2.3 Shear loads with or without lever arm ............................................................................................ 8  \n3.3 Determination of decisive bending moment in the façade panel ...................................................9  \n3.4 Verification against corner breakage of façade panels with reveal panels ..................................10  \n3.5 Determination of the decisive bending moment in the reveal panel ............................................11  \n4 ULTIMATE LIMIT STATE ............................................................................................................12  \n4.1 General......................................................................................................................................... 12  \n4.2 Design method of fasteners ......................................................................................................... 12  \n4.2.1 Resistance to breakout or pull-out failure under tension loads or compression load .................. 12  \n4.2.2 Resistance to breakout or pull-out failure under shear loads ...................................................... 13  \n4.2.3 Resistance to breakout or pull-out failure under combined tension and shear load.................... 14  \n4.2.4 Resistance to steel failure under tension loads or compression load .......................................... 15  \n4.2.5 Resistance to steel failure under shear loads .............................................................................. 15  \n4.2.6 Resistance to steel failure under combined tension and shear load ........................................... 16  \n5 DETERMINATION OF CHARACTERISTIC VALUES OF NATURAL STONE FAÇADE PANELS ACCORDING TO EN 1469 ..........................................................................................17  \n5.1 General......................................................................................................................................... 17  \n5.2 Flexural strength","cbCaikwrzr3H7jeQ","https://ap.wps.com/l/cbCaikwrzr3H7jeQ","pdf",898872,"English","# SCOPE OF THE TECHNICAL REPORT\n## Fastener\n## Façade panel\n## Type and direction of load\n## Specific terms used in this TR\n# DESIGN AND SAFETY CONCEPT\n## Design concept\n## Ultimate limit state\n# STATIC ANALYSIS\n## General\n## Loads acting on fastener\n## Determination of decisive bending moment\n## Verification against corner breakage\n## Determination of decisive bending moment in the reveal panel\n# ULTIMATE LIMIT STATE\n## General\n## Design method of fasteners\n# DETERMINATION OF CHARACTERISTIC VALUES\n## Natural stone façade panels according to EN 1469\n## Flexural strength\n## Flexural strength after weathering\n## Ultimate tension load of the fastener\n## Ultimate shear load of the fastener\n# REFERENCE DOCUMENTS","[{\"question\":\"What is the scope of TR 062 regarding fastener design?\",\"answer\":\"TR 062 provides design methods for façade fasteners that are supported by a European Technical Assessment (ETA) based on EAD 330030-00-0601. It specifies how to use characteristic resistances and distances from the ETA to design fasteners for natural stone façade panels (except slate) and ceramic tiles (stoneware).\"},{\"question\":\"Which standards and material types are covered for façade panels?\",\"answer\":\"The report applies to natural stone façade panels according to EN 1469 (excluding slate) and ceramic tiles according to EN 14411. It also notes that natural stone in practice may differ from the tested material in the ETA.\"},{\"question\":\"How does TR 062 treat verification of fastener resistance at the ultimate limit state?\",\"answer\":\"It presents verification methods for breakout or pull-out resistance and for steel failure resistance. These are addressed under tension loads, shear loads, and combined tension and shear, as part of the ultimate limit state design approach.\"}]","Design of fasteners for facade panels made of natural stone and ceramic tiles - TR 062 | PDF"]