[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-648345-105":59,"doc-detail-648345-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","design-of-concrete-chimney-mini-project-report","DESIGN OF CONCRETE CHIMNEY - Mini Project Report","","Chimneys are tall, slender structures designed to discharge waste or flue gases at higher elevations with sufficient exit velocity, ensuring dispersion into the atmosphere across a defined spread so ground concentrations remain within limits set by pollution control authorities. The mini project focuses on the analysis and working-stress design of a reinforced concrete (RC) chimney per Indian Standard IS 4998, considering wind, temperature, and dead loads. It determines stresses in steel and concrete for different shell sections while accounting for temperature gradients caused by venting hot gases.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/design-of-concrete-chimney-mini-project-report/648345/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/design-of-concrete-chimney-mini-project-report/648345.png","ImageObject",300,407,{"name":92,"@type":93},"Alexandar","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-27","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose of a concrete chimney in this project?","Question",{"text":112,"@type":113},"To discharge waste/flue gases at higher elevation with enough exit velocity so the gases disperse and reach the ground within acceptable pollution limits.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which loads are considered for analyzing the reinforced concrete chimney?",{"text":117,"@type":113},"Wind loads, temperature loads, and dead loads are considered as the main loads for the chimney analysis.",{"name":119,"@type":110,"acceptedAnswer":120},"How is the reinforced concrete chimney design approach described?",{"text":121,"@type":113},"The design is carried out analytically using the working stress method and aims to verify stresses in both steel and concrete against codal limits.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},648345,1793052817,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},962090768658,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","DESIGN OF CONCRETE CHIMNEY  \nA Mini Project Report Submitted in Partial Fulfillment of the Requirement for the Degree of  \nBACHELOR OF TECHNOLOGY  \nIN  \nCIVIL ENGINEERING  \nB.Yugandhara Reddy (15091A01F4)  \nV.Sukesh (15091A01C9)  \nP.Viswanatha Reddy (15091A01F1)  \nG.VenkataRajasekhar (16095A0138)  \nC.Saikumar (15091A01A3)  \nUnder the Esteemed Guidance of  \nDr.C.RAJARAMPh.D  \nAssistant Professor of Civil Engineering  \nDepartment of Civil Engineering  \nR . G . M College of Engineering and Technology  \n(Autonomous),  \nNandyal 518 501, A. P., INDIA  \n(A􀀎liated to J. N. T. University, A. P., INDIA)  \n(Approved by AICTE, Accredited by N.B.A, NewDelhi, NAAC-A+ Grade)  \n2015-2019  \nR . G . M College of Engineering and Technology  \n(Autonomous),  \nNandyal 518 501, A. P., INDIA  \n(A􀀎liated to J. N. T. University, A. P., INDIA)  \n(Approved by AICTE, Accredited by N.B.A, NewDelhi, NAAC-A+ Grade)  \nCERTIFICATE  \nThis is to certify that the Mini Project Report entitled \"DESIGN OF CONCRETE CHIMNEY \" submitted by  \nB.Yugandhara Reddy (15091A01F4)  \nV.Sukesh (15091A01C9)  \nP.Viswanatha Reddy (15091A01F1)  \nG.Venkata Rajasekher (16095A0138)  \nC.Saikumar (15091A01A3)  \nin partial ful􀀌llment of the requirement for the award of B.Tech in Civil Engineering in the  \nRAJEEV GANDHI MEMORIAL COLLEGE OF ENGINEERING AND TECHNOLOGY,(AUTONOMOUS)Nandyal (A􀀎liated to J.N.T University, Anantapur) is a bona􀀌de record of con􀀌de work carried out by her under our guidance and supervision. The results embodied in this Mini Project report have not been submitted to any other university or institute for the award of any Degree.  \nSignature of HSCE.  \nDr. G.SREENIVASULU Ph.DHOD and Professor  \nSignature of the guide RGMCET, NANDYAL  \nExaminer:  \nDate:  \nDedicated to my beloved parents, and teachers who have worked hard throughout my education.  \nAcknowledgements  \nWe would like to express our sincere gratitude and honour to our project guide Dr.C.RAJARAMPh.D, for his continuous support of our project, patience, motivation, enthusiasm, and a􀀋ection throughout and beyond the project. His guidance helped us a lot through the time of project.  \nWe take it as a privilege to express our thanks to the Head of the Department Dr.G.SREENIVASULU Ph.D, or his continuous help and encouragement.  \nWe are highly grateful and gratitude to Dr.T.JAYACHANDRA PRASAD, Principal, R.G.M College of Engineering and Technology, for his encouragement and inspiration at various points of time in the successful accomplishment of this Mini project.  \nWe shall remain grateful to Dr.M.SHANTHIRAMUDU, Chairman R.G.M, College of Engineering and Technology, Who has been a constant source of inspiration throughout the Mini project work and we also seek his blessings for a bright future.  \nWe shall remain grateful to Dr.M.SIVARAM, M.D, R.G.M College of Engineering and Technology, who has been a constant source of inspiration throughout project work and we also seek his blessing for bright future.  \nWe express our special thanks to the faculty members and non-teaching sta􀀋 members of this college who constantly cooperated in the completion of the Mini project work.  \nLast but no way the least, our thanks to all those who helped us in the completion of this work.  \nPROJECT ASSOCIATES  \nB.YUGANDHARA REDDY (15091A01F4)  \nV.SUKESH (15091A01C9)  \nP.VISWANATHA REDDY (15091A01F1)  \nG.VENKATA RAJASEKHAR (16095A0138)  \nC.SAI KUMAR (15091A01A3)  \nAbstract  \nChimneys are tall slender structures which are used to discharge waste/􀀍ue gases at higher elevation wiyh su􀀎cient exit velocity such that the gases and suspended (ash) are dispersed into the atmosphere over ade􀀌ned spread such that concentration,on reaching the ground is with in acceptable limits speci􀀌ed by pollution control regulatory authorities.  \nThis project deals with the analysis and design of Reinforced Concrete (RC) chimney. Such chimneys are presently designed in conformity with Indian Standard code of practice (IS 4998) . The main loads to be consid","cbCaiiqvlwJScT7M","https://ap.wps.com/l/cbCaiiqvlwJScT7M","pdf",4566561,42,"English","# Abstract\n# 1 Introduction\n## 1.1 Introduction of chimney","[{\"question\":\"What is the purpose of a concrete chimney in this project?\",\"answer\":\"To discharge waste/flue gases at higher elevation with enough exit velocity so the gases disperse and reach the ground within acceptable pollution limits.\"},{\"question\":\"Which loads are considered for analyzing the reinforced concrete chimney?\",\"answer\":\"Wind loads, temperature loads, and dead loads are considered as the main loads for the chimney analysis.\"},{\"question\":\"How is the reinforced concrete chimney design approach described?\",\"answer\":\"The design is carried out analytically using the working stress method and aims to verify stresses in both steel and concrete against codal limits.\"}]","DESIGN OF CONCRETE CHIMNEY - Mini Project Report | PDF",1792793181,106]