[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-336465-105":59,"doc-detail-336465-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","design-and-experimental-validation-of-a-metamaterial-based-sensor-for-microwave-imaging-in-breast-lung-and-brain-cancer-detection","Design and experimental validation of a metamaterial-based sensor for microwave imaging in breast, lung, and brain cancer detection","","Innovative microstrip sensor geometry is proposed for high-resolution microwave imaging (MWI) targeting early detection of breast, lung, and brain cancer. The design integrates a microstrip patch antenna fed by a coplanar waveguide, with a metamaterial (MTM) layer lens on the back side and an artificial magnetic conductor (AMC) realized as a separate layer. Negative epsilon (ENG) behavior near resonance is analyzed alongside reflectivity, transmittance, and absorption. An FR4-based prototype is experimentally validated: at 4.56 GHz the gain reaches 8.5 dBi with 3.8 dBi enhancement from the AMC, and simulations with phantoms confirm precise tumor size discrimination and improved performance.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/design-and-experimental-validation-of-a-metamaterial-based-sensor-for-microwave-imaging-in-breast-lung-and-brain-cancer-detection/336465/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/design-and-experimental-validation-of-a-metamaterial-based-sensor-for-microwave-imaging-in-breast-lung-and-brain-cancer-detection/336465.png","ImageObject",300,407,{"name":92,"@type":93},"Aria","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-08","2026-09-21",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What sensor structure is proposed for microwave imaging of cancer?","Question",{"text":113,"@type":114},"The sensor uses a microstrip patch antenna fed by a coplanar waveguide, combined with a metamaterial (MTM) lens on the back side and an artificial magnetic conductor (AMC) implemented on a separate layer.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Which performance parameters are analyzed for the AMC and the full sensor?",{"text":118,"@type":114},"The analysis covers AMC permeability and permittivity to show negative epsilon (ENG) qualities near resonance, as well as reflectivity, transmittance, and absorption.",{"name":120,"@type":111,"acceptedAnswer":121},"What experimental gain is achieved and at what resonance frequency?",{"text":122,"@type":114},"At 4.56 GHz resonance, the realized gain reaches 8.5 dBi, with 3.8 dBi gain enhancement attributed to the AMC.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},336465,1790198036,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},2336464648322,"https://ap-avatar.wpscdn.com/avatar/2200025388227c56fec?_k=1778556882303663488","[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nDesign and experimental validation of a metamaterial‑based sensor for microwave imaging in breast, lung, and brain cancer detection  \nMusa N. Hamza1*, Slawomir Koziel2,3 & Anna Pietrenko‑Dabrowska 3  \nThis study proposes an innovative geometry of a microstrip sensor for high‑resolution microwave imaging (MWI). The main intended application of the sensor is early detection of breast, lung, and brain cancer. The proposed design consists of a microstrip patch antenna fed by a coplanar waveguide with a metamaterial (MTM) layer‑based lens implemented on the back side, and an artificial magnetic conductor (AMC) realized on as a separate layer. The analysis of the AMC’s permeability and permittivity demonstrate that the structure exhibits negative epsilon (ENG) qualities near the antenna resonance point. In addition, reflectivity, transmittance, and absorption are also studied. The sensor prototype has been manufactures using the FR4 laminate. Excellent electrical and field characteristics of the structure are confirmed through experimental validation. At the resonance frequency of 4.56 GHz, the realized gain reaches 8.5 dBi, with 3.8 dBi gain enhancement contributed by the AMC. The suitability of the presented sensor for detecting brain tumors, lung cancer, and breast cancer has been corroborated through extensive simulation‑based experiments performed using the MWI system model, which employs four copies of the proposed sensor, as well as the breast, lung, and brain phantoms. As demonstrated, the directional radiation pattern and enhanced gain of the sensor enable precise tumor size discrimination. The proposed sensor offers competitive performance in comparison the state‑of‑the‑art sensors described in the recent literature, especially with respect to as gain, pattern directivity, and impedance matching, all being critical for MWI.  \nKeywords Microwave imaging (MWI), High-gain antenna, Metamaterials (MTMs), Artificial magnetic conductor (AMC), Cancer diagnosis  \nCancer belongs to the most dangerous diseases affecting humanity. Estimations indicate that by 2030 there would be 17 million cancer-related deaths and 26 million new cancer diagnoses yearly1. Gene alterations that promote abnormal development and tumor formation that can spread to other parts of the body are the cause of breast cancer2,3. The most frequent cancer in women2,3, the number of cases is expected to rise from 14 to 22 million over the course of the next 20 years4,5. Breast cancer may be successfully treated most of the time following an early detection (99% survival rate)6,7. On the other hand, the most frequent kind of cancer in the world in terms of new occurrences is lung cancer. The main risk factor for lung cancer, which causes 80% to 90% of cases, is tobacco smoking. 2.1 million new cases of cancer were recorded in 2018, making about 12% of all cases globally. Males accounted for the majority of diagnoses in 2018, with over 1.37 million cases. The regions with the greatest occurrence rates were Eastern Asia, Polynesia, Central and Eastern Europe, and Micronesia. The incidence rate is lower in women; in 2018, about 725,000 new cases were diagnosed. In 2020, lung cancer accounted for 1.8 million new fatalities, or 18% of all deaths linked to cancer. The 5-year survival rate for lung cancer is lower than that of other severe types of cancer8. In the United States, lung cancer is the second most common cancer among both men and women, after the breast cancer. It is most commonly diagnosed in men after the prostate cancer9. Medical classification of the sickness include many phases based on the size of the tumor and the location of aberrant cell proliferation throughout the human body. The early stages of lung cancer are characterized by a small tumor that has not yet spread to any lymph nodes. Identification of lung cancer in  \n1Department of Physics, College of Science, Universit","cbCaio1O8Rc7pVtG","https://ap.wps.com/l/cbCaio1O8Rc7pVtG","pdf",4020262,17,"English","# Introduction\n## Microwave imaging for cancer detection\n## Disease background: breast, lung, and brain cancer\n## Medical imaging methods\n# Sensor design and analysis\n## Microstrip patch antenna and coplanar waveguide\n## Metamaterial (MTM) lens and AMC layer\n## Electromagnetic characterization (permeability, permittivity, ENG behavior)\n## Prototype fabrication and experimental validation\n# Experimental and simulation results\n## Resonance behavior and gain enhancement\n## Radiation pattern and tumor size discrimination\n## Comparison with state-of-the-art sensors","[{\"question\":\"What sensor structure is proposed for microwave imaging of cancer?\",\"answer\":\"The sensor uses a microstrip patch antenna fed by a coplanar waveguide, combined with a metamaterial (MTM) lens on the back side and an artificial magnetic conductor (AMC) implemented on a separate layer.\"},{\"question\":\"Which performance parameters are analyzed for the AMC and the full sensor?\",\"answer\":\"The analysis covers AMC permeability and permittivity to show negative epsilon (ENG) qualities near resonance, as well as reflectivity, transmittance, and absorption.\"},{\"question\":\"What experimental gain is achieved and at what resonance frequency?\",\"answer\":\"At 4.56 GHz resonance, the realized gain reaches 8.5 dBi, with 3.8 dBi gain enhancement attributed to the AMC.\"}]","Design and experimental validation of a metamaterial-based sensor for microwave imaging in breast, lung, and brain cancer detection | PDF",1790015155,43,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/75fbd6c2355b2f00de62553e1196cc91.webp",983,1291,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/a206b8ed92d617c9278798ad11abd671.webp",982,1290,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/03f4090933b315f1b99e1fefa55236ab.webp",981,1289,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/151ef660aa386c02ab58af82770140d1.webp",980,1287]